In this research radon concentrations in soil samples of some sites of the College of Education for Women, University of Tikrit, were measured using CR-39 nuclear impact detector. Soil samples were prepared according to classical protocols whereby they were irradiated for a period of 65 days in propagation chambers chemically treated and subjected to optical microscopy to calculate nuclear effects. The results show differences in the concentrations of radon gas in the samples collected from different sites ranging between a lowest value in the location of the department of English and a highest value of in the location of the cafeteria of College compared to the radiation background of due to the geological factors that depend on the type and specifications of the soil, the amount of gases emitted from the soil, the amount of the emergence of radon from the granules of the soil and its spread through the pores of the soil to the outside.
A prey-predator model with Michael Mentence type of predator harvesting and infectious disease in prey is studied. The existence, uniqueness and boundedness of the solution of the model are investigated. The dynamical behavior of the system is studied locally as well as globally. The persistence conditions of the system are established. Local bifurcation near each of the equilibrium points is investigated. Finally, numerical simulations are given to show our obtained analytical results.
Rock failure during drilling is an important problem to be solved in petroleum technology. one of the most causes of rock failure is shale chemical interaction with drilling fluids. This interaction is changing the shale strength as well as its pore pressure relatively near the wellbore wall. In several oilfields in southern Iraq, drilling through the Tanuma formation is known as the most challenging operation due to its unstable behavior. Understanding the chemical reactions between shale and drilling fluid is determined by examining the features of shale and its behavior with drilling mud. Chemical interactions must be mitigated by the selection of suitable drilling mud with effective chemical additives. This study is describing t
... Show More3D geological model for each reservoir unit comprising the Yamama Formation revealed to that the formation is composed of alternating reservoirs and barriers. In Subba and Luhais fields the formation began with barrier YB-1 and four more barriers (YB-2, YB-3, YB-4, YB-5), separated five reservoirs (YR-A, YR-B, YR-C, YR-D, YR-E) ranging in thickness from 70 to 80 m for each of them deposited by five sedimentary cycles. In the Ratawi field the formation was divided into three reservoir units (YR-A, YR-B, and YR-C) separated by two barrier units (YB-2 and YB-3), the first cycle is missing in Ratawi field.
The study involves 1 well in Luhais field (Lu-12), 3 wells in Subba field (Su-7, Su-8, and Su-9), and 5 wells in Ratawi fi
... Show MoreThe present study includes the evaluation of petrophysical properties and lithological examination in two wells of Asmari Formation in Abu Ghirab oil field (AG-32 and AG-36), Missan governorate, southeastern Iraq. The petrophysical assessment was performed utilizing well logs information to characterize Asmari Formation. The well logs available, such as sonic, density, neutron, gamma ray, SP, and resistivity logs, were converted into computerized data using Neuralog programming. Using Interactive petrophysics software, the environmental corrections and reservoir parameters such as porosity, water saturation, hydrocarbon saturation, volume of bulk water, etc. were analyzed and interpreted. Lithological, mineralogical, and matrix recogniti
... Show MoreIn this study water quality was indicated in terms of Water Quality Index that was determined through summarizing multiple parameters of water test results. This index offers a useful representation of the overall quality of water for public or any intended use as well as indicating pollution, water quality management and decision making. The application of Water Quality Index
(WQI) with sixteen physicochemical water quality parameters was performed to evaluate the quality of Tigris River water for drinking usage. This was done by subjecting the water samples collected from eight stations in Baghdad city during the period 2004-2010 to comprehensive physicochemical analysis. The sixteen physicochemical parameters included: Turbidity, A
In this study water quality was indicated in terms of Water Quality Index that was determined through summarizing multiple parameters of water test results. This index offers a useful representation of the overall quality of water for public or any intended use as well as indicating pollution, which are useful in water quality management and decision making. The application of Water Quality Index (WQI) with ten physicochemical water quality parameters was performed to evaluate the quality of Euphrates River water for drinking usage. This was done by subjecting the water samples collected from seven stations within Al-Anbar province during the period 2004-2010 to comprehensive physicochemical analysis. The ten physicochemical parame
... Show MoreIn this study water quality was indicated in terms of Water Quality Index that was determined through summarizing multiple parameters of water test results. This index offers a useful representation of the overall quality of water for public or any intended use as well as indicating pollution, water quality management and decision making. The application of Water Quality Index (WQI) with sixteen physicochemical water quality parameters was performed to evaluate the quality of Tigris River water for drinking usage. This was done by subjecting the water samples collected from eight stations in Baghdad city during the period 2004-2010 to comprehensive physicochemical analysis. The sixteen physicochemical parameters included: Turbidity,
... Show More