Magnetic Resonance Imaging (MRI) is a medical indicative test utilized for taking images of the tissue points of interest of the human body. During image acquisition, MRI images can be damaged by many noise signals such as impulse noise. One reason for this noise may be a sharp or sudden disturbance in the image signal. The removal of impulse noise is one of the real difficulties. As of late, numerous image de-noising methods were produced for removing the impulse noise from images. Comparative analysis of known and modern methods of median filter family is presented in this paper. These filters can be categorized as follows: Standard Median Filter; Adaptive Median Filter; Progressive Switching Median Filter; Noise Adaptive Fuzzy Switching Median Filter; and Different Applied Median Filter. The de-noising technique performance for each one is evaluated and compared using Peak Signal Noise Ratio, Structural Similarity index Metric, and Beta metric as quantitative metrics. The experimental results showed that the latest de-noising technique, Different Applied Median Filter (DAMF), produced better results in removing impulse noise compared with the other de-noising techniques. However, this filter produced de-noised image with nonlinear edges in high-density noise. As a result, noise removal from images is one of the low-level images processing which is considered as a first step in many image applications. Therefore, the efficiency of any image processed depends on the efficiency of noise removal technique.
Aqueous Two Phase System (ATPS) or liquid-liquid extraction is used in biotechnology to recover valuable compounds from raw sources. In Aqueous Two-Phase Systems, many factors influence the Partition coefficient, K, (which is the ratio of protein concentration in the top phase to that in the bottom phase) and the Recovery percentage (Rec%). In this research, two systems of ATPS were used: first, polyethylene glycol (PEG) 4000/Sodium citrate (SC), and the second, PEG8000/ Sodium phosphate (SPH), for the extraction of Bovine Serum Albumin (BSA). The behavior of Rec% and K of pure (BSA) in ATPS has been investigated throughout the study by the effects of five parameters: temperature, concentration of polyethylene glycol (P
... Show MoreComplexes of some metal ions ( Mn(I? ) , Co(??) , Ni(??) ,Cu (??) , Zn(I?) , Cd (??) , and Hg(??) ) with 8-hydroxyquinoline (Oxine) and 2- Picoline (2-pic ) have been synthesized and characterized on the basis of their FT-IR. and Uv-visible spectroscopy ,atomic absorption molar conductivity measurements and magnetic susceptibility ,from the results obtained the following general formula has been given for prepared complexes [M (oxine)2 (2-pic)2]where M = M(??) = Mn , Co , Ni , Cu , Zn , Cd , Hg(oxine)- = ionic ligand 8-hydroxyquinolin (oxinato)(2- pic) = 2- picoline
Out of 150 clinical samples, 50 isolates of Klebsiella pneumoniae were identified according to morphological and biochemical properties. These isolates were collected from different clinical samples, including 15 (30%) urine, 12 (24%) blood, 9 (18%) sputum, 9 (18%) wound, and 5 (10%) burn. The minimum inhibitory concentrations (MICs) assay revealed that 25 (50%) of isolates were resistant to gentamicin (≥16µg/ml), 22 (44%) of isolates were resistant to amikacin (≥64 µg/ml), 21 (42%) of isolates were resistant to ertapenem (≥8 µg/ml), 18 (36%) of isolates were resistant to imipenem (4- ≥16µg/ml), 43 (86%) of isolates were resistant to ceftriaxone (4- ≥64 µg/ml), 42 (84%) of isolates were resistant to ceftazidime (1
... Show MoreInteracting boson model version one has been used in the present
theoretical calculations. The energy levels & their transitions for dynamical symmetry 0(6), SU(3), U(5), ground-state band, Beta band, Gamma band, B(E2), Ot, B(Ml), ,u,gt and 6(£2/Ml)have been calculated to deduce the limit of Pt-198, Z=78. The present results confirmed the nuclear behavior of this isotope lay in the
transitional region 0(6), SU(3) U(5). The calculations of 021 + & 022+
showed that the shape of this isotope is oblate according to Q21+ and pr
... Show MoreThe variety of ideas and freedom of expression among the authors who are looking for everything new that serves the goals of musical and aesthetic expression, which calls for the use of traditional musical instruments with the great composition of musical instruments known as the orchestra represents a great challenge in several aspects. The incompetence of some of these instruments or limited capabilities or its costly method of performance sometimes forbids its use permanently in this great composition. It was necessary to have some problems facing the composer and the player on the one hand and the recipient on the other hand, who must be looking for perfection. Among those instruments that are used regularly in the works of the orche
... Show MoreIt is shown that pure and 3% boron doped a-Si0.1Ge0.9:H and a-Si0.1Ge0.9:N thin films
could be prepared by flash evaporation processes. The hydrogenation and nitrogenation
are very successful in situ after depositing the films. The FT-IR analysis gave all the
known absorbing bonds of hydrogen and nitrogen with Si and Ge.
Our data showed a considerable effect of annealing temperature on the structural and
optical properties of the prepared films. The optical energy gap (Eopt.) of a-Si0.1Ge0.9
samples showed to have significant increase with annealing temperature (Ta) also the
refractive index and the real part of dielectric constant increases with Ta, however the
extinction coefficient and imaginary part of dielect
This paper calculated the Duration Magnitude (MD) equation using data from the Iraqi Meteorological Organization and seismology (IMOS). It is an empirically determined equation and expressed as:
The epicentral distance and local geological conditions affect the duration of the coda. The data is obtained from 7 seismic stations in the network. The new proposed duration magnitude equation results from applying linear regression analysis to the data of a seismic signal duration with correlation coefficient R2=0.76; and a standard deviation value of 0.049. Station corrections indicated by Sc are also specified for the seismic stations that range from -0.024 to + 0.02.