One of the bigger problems in drinking water is disinfection by-products (DBPs) that come from chlorinated disinfection. This study’s goal was to evaluate the drinking water in Al-Yarmouk Teaching Hospital, Ibn Sina Hospital and Ibn-Al-Nafis Hospital. Samples were collected between October 2018 and September 2019. Physical and chemical characteristics of the water were studied, including (temperature, hydrogen ion (pH), total dissolved solids (TDS), electrical conductivity (EC), turbidity, free residual chlorine, total organic carbon (TOC), total trihalomethanes (THMs), total halo acetic acid (THAAs)). Data analysis showed the highest value of study temperature, pH, TDS, EC, turbidity, free residual chlorine and TOC which was 37oC, 8.4,790 mg/l, 1251 µS/cm-1, 15 NTU, 1.7 mg/l, and 6.7 mg/l respectively. Total trihalomethanes (THMs) results of drinking water samples from different sites showed that the highest value was 129.6 µg/l in Ibn Sina Hospital during summer while the lowest value was 41.3 µg/l in Ibn Sina Hospital in winter. The results of total halo acetic acid (THAAs) of drinking water sampled from different sites showed that the highest value of 72.9 µg/l was recorded in the sample collected from Ibn Sina Hospital during summer and the lowest THAAs water content of 40.2 µg/l was obtained in the sample collected from Ibn-Al-Nafis during winter. The results of this research were acceptable and within the range of Iraqi standards.
Three stations were chosen on the water treatment plan of al- madaan .The Samples collected from the (Raw water) and the Sedimentation, filtration and storage water and the drinking water of outlet. Coliform densities T.S and F.C and TS and F.S and total bacterial count as bacteriological pollution indicators, as moste probable number (MPN) method was studied in test. Also some of the chemical characteristics of the water like pH , total suspended solid T.S.S, T.D.D.and S04 , T.Hardness , Ca++ , Mg++ . From the results it were indicated . The study showed the drinking water of outlet (distriputed in system) was agree with WHO criteria and Iraqi limits standards .
The objective of this study is to determine the concentration of copper and lead (mg/L) in drinking water by using absorption spectrophotometic and Atomic Absorption spectrophotometric method from different area in Baghdad and with different intervals , The results show that the concentration of copper and Lead ( mgL) in tap water which remains motionless in plumbing system for following periods one hours, 3 hours, 6 hours, 12 hours, 24 hours, 7 days and 14 days are (1 , 2.2 , 4 , 5.3 , 7.5 , 10 and 16 mgL copper ) & ( 0.3, 0.5 , 0.8 , 1 , 2.5 , 3 , 3.8 mg /L lead ) respectively .from these results its clear that high levels of copper & Lead occur if tap water comes in contact with copper - lead plumbing and copper lead -containing fix
... Show Morestudy was conducted on a stretch of Tigris river crossing Baghdad city to determine the concentration of some chlorophenols pollutants. Aqueous samples were preliminary enriched about 500 times and the chlorophenols have determined using high performance liquid chromatography HPLC. Limits of detection LOD were (0.007–0.012 mg L-1), relative standard deviations RSD% were 2.4%–5.59% and relative recoveries were 51.06%– 104.07%. The existence of chlorophenols in Tigris river was in the range 0.023–4.596 mg L-1. The developed method suggested in this study can be applied for routine analysis and monitoring of chlorinated phenols in environmental aqueous samples.
In the present study ten samples of bottled water from Baghdad conservative were taken to measure the concentration of radon gas by using nuclear track detector LR-115.The result obtained are varying from(0.033)to(0.007)pCi.l-1and these values are very low than the allowed limits (5) pCi.l-1, and specific activity from bottled water has been calculated which was vary from (0.00027)to(0.00126) Bq.l-1 and these values are very low than allowed limits (0.0123) Bq.l-1 that mean the bottled water was treated with good treatment to decrease the side effect of radon
Forty-four bottles of drinking water were collected from the local markets of Basra City and stored in the laboratory refrigerator at 4ºC until the physical, chemical and biological measurements were carried out. The results showed a discrepancy in the compatibility of the specifications written on the drinking water bottle label with the sample measurements as well as the variation in the results with the Iraqi standards for bottled water. The percentage of bottled water that is not safe for drinking was 88.5% of the total samples of the study. This value is high and an indication of lack of control over marketing from the imported or produced in the local labs, s
... Show MoreAn evaluation of pollution level has been done for drinking water which is used in Kirkuk city by heavy metals ( As,Cd,Cu,Fe,Mn,Ni,Zn,Cr,Pb) samples were collected during wet and dry of 2016-2017 from Kirkuk unified water supplied project (WTP) which is supply the city with drinking water, as well as from water of tanks type (GST2), and also from (tap water) (Zone3). The results showed the concentration of the (As,Cd,Cu,Fe,Mn,Ni,Zn,Cr,Pb)inppbfor (WTP)are (0.5,0.6,6.45,38,4.6,2.5,6537,0.58,1.4) (0.6,0.8,6.76,46,5.5,3.5,6675,1,2.4) for (GST) (0.5,0.63,6.46,52.3,4.4,3.6,6550,0.6,2.5) (0.60,0.7,6.78,63.7,6.7,3.7,6680,1.1,2.6) and for tap water are (0.53,0.65,7.00,60.2,4.4,3.65,7200,0.8,2.7) (0.60, 0.71, 7.10, 67.6, 6.8,3.75,7320,0.9,2.75) f
... Show MoreBackground: This study aimed to determine the amount of fluoride in commercially available bottled drinking water in Al-Basra city, Iraq Materials and Methods: Eleven brands of bottled drinking water were obtained from supermarkets in Al-Basra city, Iraq. Five samples of 10 ml. were taking from each one of brands and the fluoride was determined by using fluoride ion selective electrode. Results: The highest fluoride concentration was present in BADIOT brand (1.174 mg/L) while the lowest was in Barakat brand (0.038 mg/L). One way ANOVA test showed a highley significant difference among different commercially branded types. Coclusions: Bottled water available in Al-Basra city contains less concentration of fluoride ion than normal values
... Show MoreSource, sedimentation, coagulation, flocculation, filter, and tank are parts of a water treatment plant. As a result, some issues threaten the process and affect the drinking water quality, which is required to provide clean drinking water according to special standards and international and local specifications, determined by laboratory results from physical, chemical, and biological tests. In order to keep the water safe for drinking, it is necessary to analyze the risks and assess the pollution that occurs in every part of the plant. The method is carried out in a common way, which is monitoring through laboratory tests, and it is among the standards of the global and local health regulators
Antibiotics present the greatest threat to soil and aquatic ecosystems among the different therapeutic groups of medicines (which include prescription drugs and treatments for cancer). The strongest drugs, antibiotics, have been utilized to stop the growth of microorganisms or eradicate them. Using high-performance liquid chromatography technology with fluorescence detection, the amounts of levofloxacin and tetracycline in the wastewater from three hospitals (Medical City, AlKindi, and Al-Yarmouk) were determined. Levofloxacin and tetracycline were chosen in this study because they are the most important water pollutants. These antibiotic residues were separated and measured using a gradient elution technique on a reverse-phase C18 co
... Show More