Determination of vitamin B6 (pyridoxine hydrochloride) was described using high performance liquid chromatographic method. The analysis was achieved by cosmos IL 5C18-MS-II column (250 mm x 4.6 mm i. d., 5µm particle size) at room temperature. The mobile phase used was Acetonitrile, buffer solution (Citric acid, Na2HPO4 pH4) buffer solution in the ratio (70:30) (V: V). the flow rate was set to 1.25 mL.min-1 and the retention time 1.82 min with UV-detection at 282 nm. Beer's law was obeyed over the concentration range 10-1250 µg.mL-1. The method was accurate (relative error % less than 0.05%), precise (RSD better than ±1.05%), average recovery 100.05%, with a limit of detection and quantification of 2.2μg.ml−1, and 7.34μg.mL−1 respectively. The proposed method was successfully applied to determine the pyridoxine hydrochloride in pharmaceutical preparations in both forms of tablet and injection
A specific, sensitive and simple method was used for the determination of: vitamin B9 (Folic acid) in pure and pharmaceutical formulations using continuous flow injection analysis. The method is based on formation of ion pair compound between folic acid and ammonium molybdate in an aqueous medium to obtain a gray precipitate complex, using homemade; Ayah-6SX1-ST-2D solar cell CFI Analyzer. Optimum parameters was studied to increase the sensitivity for developed method. The linear range for the calibration graph was 0.01-0.6 mMol.L-1 of vitamin B9 and LOD was 131.994 ng/sample with correlation coefficient ( r ) of 0.9810, RSD% was lower than 0.1%, (n=9) for the determination of vitamin B9 at concentration (0.07and 0.5) mMol.L-1 respectiv
... Show MoreBy using precipitation polymerization, liquid electrodes of polymers imprinted with Mebeverine hydrochloride and metronidazole benzoate were created whereas the imprinted polymer (MIP) and non imprinted (NIP) polymers were prepared by using Mebeverine hydrochloride and Metronidazole benzoate qua a template. In the polymerization process, 2-Acrylamido-2-methyl-1-propane Sulphonic acid (AMPS) or 1-Vinylimidazole (VIZ) was used qua monomer, pentaerythritol triacrylate (PETRA) or Divinylbanzene (DVB) was used qua a cross-linker while benzoyl peroxide (BPO) was used as an initiator. The MIP membranes and the membranes of NIP were created by using Dibutyl Sebacate (DBS) and Tris(2-ethylhexyl)phosphate(TEHP) qua plasticizers
... Show MoreThis researd exhibit's a method to determine the change in Gibbs function,(enthai py,entropy. and specific heat capacity) tor monovariant heterogeneous equilibria .The thermodynamical quan.tities were obtained jndirectly with m the measurment of temperature dependent on eql,lilibrium system.
A new turbidimetric-flow injection method is described for the determination of chlorpromazine HCl in pure and pharmaceutical preparation. The method is characterized by simplicity, sensitivity and fast, it is based on formation of ion pair compound between chlorpromazine HCl and Potassium hexacyanoferrate(III) in an acid medium for the formation of greenish yellow precipitate. This precipitate was determined using homemade Linear Array Ayah 5SX1-T-1D continuous flow injection analyser. Optimum concentrations of chemical reactants, physical instrumental conditions have been investigated. The linear dynamic range of chlorpromazine HCl was 3-30 mmol.L-1 while correlation coefficient (r) was 0.9929 and percentage linearity (%r2) C.O.D was 9
... Show MoreRadioactive liquid waste contaminated with cesium-137 found in the radiochemistry laboratories at Tuwaitha site, south of Baghdad, was treated in this work. Bentonite was used as a sorbent material for the removal of radioactive cesium-137 from liquid waste by ion exchange method. The results indicated that the best removal efficiency obtained was 95.13% with experimental conditions of 2 h mixture time, 0.04 g sorbent mass, and pH=10 for the radioactive liquid. It was found that the experimental results match well with Langmuir and Freundlich models, with better matching with the latter.
Detergent is one of the pollutants that poses significant threats to ecological systems. Detergents can also dissolve in wastewater and negatively impact the efficiency of wastewater treatment facilities. They are used for a variety of functions, most notably hygiene, and are an integral aspect of human life. This means that there are a variety of routes by which detergent components can reach the environment. In this Study, twenty-three detergent samples from local markets in Baghdad. The aim of this study is to investigate the concentration of heavy metals Cobalt (Co), Chromium (Cr),Lead (Pb),Zinc (Zn), Iron (Fe) and Cadmium (Cd) in some detergents using Atomic Absorption Spectrophotometer. The results of the concentration of heavy elemen
... Show MoreIn the present study, the physical characteristics of elastomer (EL) blend with natural polymers such as polyvinyl alcohol (PVA), Dexrin (D), Arabic gum (AG), and corn starch (CS) based on high-density fiberboard wood adhesives were investigated. The EL blends were prepared by dissolving AG, D, PVA, and CS in deionized water at 70 °C for 1 h under magnetic stirring continuously until the solution was clear, and blends were made with a weight of 60/40 (w/w); then were cast into a mold with a 20 cm diameter and left at room temperature for 24 h to ensure complete water removal and drying of the samples. The prepared EL and EL blend structures, adhesion strengths, roughness, wettings, and dielectric strengths, were investigated. The modifi
... Show MoreSimple and rapid spectrophotometric determination of furosemide (FUR) has been investigated .The method is based on acid hydrolysis of FUR to free primary aromatic amine and diazotization followed by coupling with 3, 5 di methyl phenol (3, 5-DMPH) at basic medium. The absorbance was measured at 434 nm, the method was optimized for best condition, and beers’ law is obeyed over the range of 0.4-50 µg.mL-1 with molar absorptivity and sandal’s sensitivity 1.3899 x104 L moL-1 .cm-1 and 0.0238x104 µg.cm-2 respectively. Analysis of solution containing nineteen different concentrations of FUR gave a correlation coefficient of (0.9999) a
... Show MoreBack ground: Cancer is the second leading cause of death throughout the world. Breast cancer, is one of the leading mortality reasons in women from Western Countries, in Iraq, breast cancer is the second reason of death After cardiovascular Diseases.
Material and method:
The study was carried out of period from October/2016-january /2017 and included (90) serum samples for Iraqi women suffered from breast cancer . Samples were divided into two groups ,the first group included (66) patients (females) their age rang (22-55) years which attended to (tumor unit) at medical city educational oncology hospital and Al-Amal Al-Waatanii hospital in Baghdad ,the second group included (38) for
... Show More