Determination of vitamin B6 (pyridoxine hydrochloride) was described using high performance liquid chromatographic method. The analysis was achieved by cosmos IL 5C18-MS-II column (250 mm x 4.6 mm i. d., 5µm particle size) at room temperature. The mobile phase used was Acetonitrile, buffer solution (Citric acid, Na2HPO4 pH4) buffer solution in the ratio (70:30) (V: V). the flow rate was set to 1.25 mL.min-1 and the retention time 1.82 min with UV-detection at 282 nm. Beer's law was obeyed over the concentration range 10-1250 µg.mL-1. The method was accurate (relative error % less than 0.05%), precise (RSD better than ±1.05%), average recovery 100.05%, with a limit of detection and quantification of 2.2μg.ml−1, and 7.34μg.mL−1 respectively. The proposed method was successfully applied to determine the pyridoxine hydrochloride in pharmaceutical preparations in both forms of tablet and injection
A simple, rapid and sensitive spectrophotometric method has been developed for the determination of captopril in aqueous solution. The method is based on reaction of captopril with 2,3-dichloro 1,4- naphthoquinon(Dichlone) in neutral medium to form a stable yellow colored product which shows maximum absorption at 347 nm with molar absorptivity of 5.6 ×103 L.mole-1. cm-1. The proposed method is applied successfully for determination of captopril in commercial pharmaceutical tablets.
A sensitive spectrofluorimetric method for the determination of glibenclamide in its tablet formulations has been proposed. The method is based on the dissolving of glibenclamide in absolute ethanol and measuring the native fluorescence at 354 nm after excitation at 302 nm. Beers law is obeyed in the concentration of 1.4 to 10 µg.ml-1 of glibenclamide with a limit of detection (LD) of 0.067 µg.ml-1 and a standard deviation of 0.614. The range percent recoveries (N=3) is 94 - 103.
An Indirect simple sensitive and applicable spectrofluorometric method has been developed for the determination of Cefotaxime Sodium (CEF), ciprofloxacin Hydrochloride (CIP) and Famotidine (FAM) using reaction system bromate-bromide and acriflavine (AF) as fluorescent dye. The method is based on the oxidation of drugs with known excess bromate-bromide mixture in acidic medium and subsequent determination of unreacted oxidant by quenching fluorescence of AF. Fluorescence intensity of residual AF was measured at 528 nm after excitation at 402 nm. The fluorescence-concentration plots were rectilinear over the ranges 0.1-3.0, 0.05-2.6 and 0.1-3.8 µg ml-1 with lower detection limits of 0.013, 0.018 and 0.021 µg ml-1 an
... Show MoreChromatographic and spectrophotometric methods for the estimation of mebendazole in
pharmaceutical products were developed. The flow injection method was based on the oxidation of
mebendazole by a known excess of sodium hypochlorite at pH=9.5. The excess sodium hypochlorite is then
reacted with chloranilic acid (CAA) to bleach out its color. The absorbance of the excess CAA was recorded
at 530 nm. The method is fast, simple, selective, and sensitive. The chromatographic method was carried out
on a Varian C18 column. The mobile phase was a mixture of acetonitrile (ACN), methanol (MeOH), water
and triethylamine (TEA), (56% ACN, 20% MeOH, 23.5% H2O, 0.5% TEA, v/v), adjusted to pH = 3.0 with
1.0 M hy
A rapid and sensitive method for the determination of amoxicillin trihydrate (AMXT) based on the diazo-coupling reaction was studied. Sulphanilic acid diazotizes with nitrite ion in acidic medium to produce a water soluble, colorless diazonium ion, which subsequently coupled with AMXT to form a colored azo dye in the alkaline medium, having maximum absorption at 455 nm. The calibration graph showed that Beer's law is obeyed over the concentration range of 0.3 – 30.0 μg/mL of AMXT, with the detection limit of 0.15 μg/mL and molar absorptivity was 2.3 × 104 L/mol.cm. The accuracy and the precision were acceptable depending upon the values of error percentage and relative standard deviation. The influence of common interfer
... Show MoreA simple, rapid and environmentally friendly dispersive liquid–liquid microextraction method-based spectrophotometric method for the trace determination of folic acid has been developed. The proposed method is based on the formation of a deep yellow product via reaction of folic acid and 1,2-naphthoquine-4-sulfonate at pH = 9. The formed complex was extracted using a mixture of chloroform and ethanol. Then, the tiny organic droplets were measured at λ = 520 nm. At the optimum conditions, linearity was ranged from 0.05 to 1.5 μg/mL for the standard and samples, with a linear correlation coefficient of 0.9996. The detection limits were 0.02, 0.027, 0.03, 0.02 and 0.04 μg/mL for standard, tablet (5 mg), tablet (1 mg), syrup and fl
... Show More