Preferred Language
Articles
/
ijs-766
Biosorption of Pb and Ni From Aqueous Solution by Staphylococcus Aureus, Pantoea and Pseudomonas Aeruginosa
...Show More Authors

     The presence of heavy metal in environment associated with several health problems. The clean up environment from lead (Pb) and Nickel (Ni) represent major challenges. In his study, planktonic and immobilized bacteria were used to purify the water from Pb and Ni in Lab. In the present study, three bacterial isolates of Staphylococcus aureus (isolated from wound swaps), Pseudomonas aeruginosa (isolated from wound swaps) and Pantoea (isolated from urine samples) and identified using biochemical methods to check their ability to biosorb Pb and Ni. Ten PPM of Pb and Ni were added to the deionized distilled water and 107 c.f.u. of planktonic bacteria were used to biosorpe Pb and Ni. Similar experiment was repeated but in this case, the immobilized bacteria (S. aureus, Pantoea, and P. aeruginosa) on silica gel and eggshells were used. It was found that S. aureus decreased the level of Pb and Ni significantly (P<0.05) in planktonic and immobilized form. Pantoea decreases the level of Ni only in planktonic form. This bacteria decreased the level of Pb and Ni significantly when it immobilized on silica gel and eggshells (P<0.05). P. aeruginosa could not decrease the level of Pb and Ni when it was in planktonic form but it can decrease the level of heavy metals in the immobilized form on silica and eggshells (P<0.05). It can be concluded that the studied bacteria can purify water from heavy metals in immobilized status more efficiently than planktonic form.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Feb 27 2022
Journal Name
Iraqi Journal Of Science
Measurement and Analysis of the Distribution of Pb-214 Lead Isotope in Baghdad Soil using Remote Sensing Techniques
...Show More Authors

     The present research aims to measure concentration of lead  Pb214 in soil using remote sensing and GIS, associated radiological hazards in Baghdad, Iraq. Concentration of specific radioactivity of radioactive elements was measured and analyzed naturally and artificially in 48 soil samples for separate sites from Baghdad, Iraq using crystalline spectroscopy to detect germanium. The average radioactivity concentrations of lead were found, as it was found to have varying values ​​from one site to another, as most of them exceeded the international permissible limit, as the highest concentration was recorded at 180 Bq in the sample H28 in Waziriyah district. Battery Lab (1), and the lowest concentration valu

... Show More
View Publication Preview PDF
Scopus (4)
Crossref (2)
Scopus Crossref
Publication Date
Tue Jan 01 2013
Journal Name
Journal Of The College Of Basic Education
The Inhibitory effect of pyocyanin pigment produced by Pseudomnas aeruginosa on biofilm formation of Klebseila pneumoniae
...Show More Authors

Materials and Methods Bacterial strains P. aeruginosa was obtained from postgraduate students Laboratories of Biology Department/College of Science/University of Baghdad. That previously isolated from patient suffering from Cystic Fibrosis. API 20 NE system was employed for the identification of P. aeruginosa. A total of 122 urine specimens were collected in the period between of mid of July until to the mid of September of 2010 from AL-Kadhmiya Teaching Hospital in Baghdad City. Specimens were collected from out-patients in sterile screw cupped containers. Regarding inpatients, catheter was withdrawn and cut

Preview PDF
Publication Date
Fri Jun 24 2022
Journal Name
Iraqi Journal Of Science
Vehicle Indoor Air pollution with Fungi Generated by Air Conditioning Systems (AC) and Treatment by Using Aqueous Extracts Mushroom (Ganoderma lucidum)
...Show More Authors

Vehicle Air Conditioning (AC) systems are used in countries that suffer high temperature degrees during the summer season, one of these countries is Iraq. Most passengers suffer manifestations which may lead to Allergic or Respiratory diseases as they inhale polluted air produced by AC systems.
In this study 10 vehicle were selected randomly on the basis of noxious odors emitted from AC systems. Indoor air samples were collected by using impaction method and using Sabouraud's dextrose agar to grow and isolate dominant fungi species accompanied with AC polluted air. Dust particle diameters aggregated in AC filters were measured because the particles work as transporters to carry fungi then get inhaled by the passengers. After isolating

... Show More
View Publication Preview PDF
Publication Date
Sun Apr 23 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Preparation And Study Of Some Electrical Properties Of Mn-Ni Fe2O4
...Show More Authors

 In this study, Mn-Ni Ferrite was prepared by using two composites of manganese ferrite ( MnFe2o4 )  and Nicle Ferrite ( NiFe2O4) tested by X-Ray diffraction (XRD) method. The dielectric constant (𝜀̅) and the dielectric loss tangent (𝑡𝑎𝑛 𝛿) were studied for the ferrite system prepared at different frequencies (100, 200… and 5000 kHz). It was found that the values of (𝜀̅) and (𝑡𝑎𝑛 𝛿) decrease with the  increase of frequencies.

View Publication Preview PDF
Publication Date
Wed Jan 01 2014
Journal Name
Int. J. Adv. Res
Antibacterial activity of parsley and celery aqueous extract on the isolated bacteria from children UTI in Erbil city‏
...Show More Authors

Publication Date
Fri Feb 25 2022
Journal Name
Heat And Mass Transfer
Optimization, equilibrium, kinetics and thermodynamic study of congo red dye adsorption from aqueous solutions using iraqi porcelanite rocks
...Show More Authors

View Publication
Scopus (8)
Crossref (6)
Scopus Clarivate Crossref
Publication Date
Wed May 10 2023
Journal Name
Journal Of Engineering
ANALYTICAL SOLUTION OF UNSATURATED SOIL WATER FLOW FROM A POINT SOURCE
...Show More Authors

Water flow into unsaturated porous media is governed by the Richards’ partial differential equation expressing the mass conservation and Darcy’s laws. The Richards’ equation may be written in three forms,where the dependent variable is pressure head or moisture content, and the constitutive relationships between water content and pressure head allow for conversion of one form into the other. In the present paper, the “moisture-based" form of Richards’ equation is linearized by applying Kirchhoff’s transformation, which
combines the soil water diffusivity and soil water content. Then the similarity method is used to obtain the analytical solution of wetting front position. This exact solution is obtained by means of Lie’s

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Thu Mar 31 2016
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Extraction of Phenol from Aqueous Solutions Using Bulk ionic Liquid Membranes
...Show More Authors

Room temperature ionic liquids show potential as an alternative to conventional organic membrane solvents mainly due to their properties of low vapour pressure, low volatility and they are often stable. In the present work, the technical feasibilities of room temperature ionic liquids as bulk liquid membranes for phenol removal were investigated experimentally. In this research several hydrophobic ionic liquids were synthesized at laboratory. These ionic liquids include (1-butyl-3-methylimidazolium bis (trifluoromethylsulfonyl) imide[Bmim][NTf2], 1-Hexyl-3-methylimidazolium bis (trifluoromethylsulfonyl) imide[Hmim][NTf2], 1-octyl-3-methylimidazolium bis (trifluoromethylsulfonyl)imide[Omim][NTf2],1‐butyl

... Show More
View Publication Preview PDF
Publication Date
Sat Oct 01 2011
Journal Name
Journal Of Engineering
REMOVAL OF CHROMIUM(VI) FROM AQUEOUS SOLUTIONS USING SAWDUST AS ADSORBENT
...Show More Authors

In the present study, a low cost adsorbent is developed from the naturally available sawdust
which is biodegradable. The removal capacity of chromium(VI) from the synthetically prepared
industrial effluent of electroplating and tannery industrial is obtained.
Two modes of operation are used, batch mode and fixed bed mode. In batch experiment the
effect of Sawdust dose (4- 24g/L) with constant initial chromium(VI) concentration of 50 mg/L and
constant particle size less than1.8 mm were studied.
Batch kinetics experiments showed that the adsorption rate of chromium(VI) ion by Sawdust
was rapid and reached equilibrium within 120 min. The three models (Freundlich, Langmuir and
Freundlich-Langmuir) were fitted to exper

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Feb 20 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Removal of Chlorpyrifos (Dursban) Pesticide from Aqueous Solutions using Barley Husks
...Show More Authors

The removal of chlorpyrifos pesticide from aqueous solutions was achieved by adsorption using low cost agricultural residue as adsorbent surface; barley husks. Several variables that affect the adsorption were studied including contact time, adsorbent weight, pH, ionic strength, particle size and temperature. The absorbance of the solution before and after adsorption was measured by using UV-Visible spectrophotometer. The equilibrium data was suitable with Langmuir model of adsorption and the linear regression coefficient R2 = 0.9785 at 37.5°C was used to knowledge the best fitting isotherm model. The general shape of the adsorption isotherm of chlorpyrifos on barley husks consistent with (H3-type) on the Giles classification. Several

... Show More
View Publication Preview PDF