Preferred Language
Articles
/
ijs-7439
Selective Extraction of Metformin in Pharmaceutical Preparation via Synthesized MIP-SPE Techniqu

       This work demonstrates the synthesis and storage of molecular-imprinted polymers (MIP) at room temperature using bulk polymerisation of Metformin (Met) characterized by high sensitivity, low cost, and high stability. To ensure an acceptable adsorption capacity, the research employed 0.8:4:20 mmol ratios of template, monomer, and cross-linking agents for the polymerization. A functional monomer, 2-acrylamido-2-methyl-1-propane sulphonic acid C7H13NO4S, was cross-linked with N,N-methylene bisacrylamide C7H10N2O2 to form Met-MIP, which could be characterized using a UV-VIS spectrophotometer at 236 nm, FT-IR spectroscopy, and scanning electron microscopy. The elution process that was applied to the template Metformin from the Met-MIP created cavities that were caused by the porogenic mixture solution of methanol, chloroform, and acetic acid (70:20:10, respectively). In accordance with the Freundlich isotherm model, Met-MIP had a maximum adsorption capacity of 5.2998 µmol/g and a template to monomer ratio of 1:2. A solid-phase extraction syringe packed with molecular imprinted polymers was used for the selective separation and pre-concentration of Metformin from aqueous solutions and estimation of Metformin by MIP and HPLC instruments in multiple pharmaceutical drugs of Metformin from several sources. The comparison with standard analytical techniques by MIP and RP-HPLC showed no significant difference between the two methods.

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Apr 30 2023
Journal Name
Iraqi Journal Of Science
Turbidimetric Determination of Metoclopramide Hydrochloride in Pharmaceutical Preparation via the Use of A new Homemade Ayah 6SX1-T-2D Solar Cell-Continuous Flow Injection Analyser

A newly developed analytical method characterized by its speed and sensitivity for the determination of metoclopramide hydrochloride (MCP-HCl) in pure and pharmaceutical preparation via turbidimetric measurement (0-180o) by Ayah 6SX1-T-2D Solar cell-CFI Analyser. The method was based on the reaction of phosphomolybdic acid with metoclopramide hydrochloride in acidic medium to form yellowish white precipitate for the ion-pair complex. Turbidity was measured via the reflection of incident light that collides on the surface precipitated particles at 0-180o. Chemical and physical parameters were studied and optimized. The calibration graph was linear in the range of 0.0005-3 or 0.0005- 4 mMol.L-1, with correlation coefficient r = 0.9947&

... Show More
View Publication Preview PDF
Publication Date
Sun Apr 09 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Preparation of One of Metformin Derivatives and Study Its Effect on Some Biochemical Parameters in Blood Sera of Rabbits

   This study aimed to synthesize a novel amide prodrug of metformin with aspirin by amide bond. The structure was characterized by (FTIR, 1H-NMR, 13C-NMR and CHNO) ,Purification of the prepared compound was using column chromatography.          Using of 40 rabbit having the same weight and devided into 4 groups (4x10) the first group (G1): (the control healthy group) was given drink water and didn’t give any material, second group(G2):( the control infected group) was given hydrogen peroxide concentration  % 0.5 until infecting diabetes  mellitus,  third group(G3): was given hydrogen peroxide concentration as in (G2) and ( 250 mg/kg) of aspirin and (348.8 mg/kg

... Show More
View Publication Preview PDF
Publication Date
Mon Sep 25 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Spectrophotometric Determination of Cefotaxime via Diazotization Reaction in Pure and Pharmaceutical Samples

      An accurate and sensitive spectrophotometric method has been developed for the determination of cefotaxime (CEF) in pure and pharmaceutical samples. The suggested method depended on the coupling reaction between diazotized cefotaxime and 3,5-dimethyl phenol (3,5-DMPH) in basic medium to form light orange, water soluble dye, that is stable and has a maximum absorbance at 497nm. The calibration graph was liner over the concentration range (1-70) µg.mL-1 with LOD of 0.750 µg.mL-1 and LOQ of. 2.740 µg. mL-1, sandal sensitivity of 0.0526 µg. cm-2 . molar absorptivity 11328 Lmol-1 cm-1 . The stoichiometry composition was found by Jobs a

... Show More
View Publication Preview PDF
Publication Date
Fri Dec 01 2023
Journal Name
Baghdad Science Journal
Fabrication of PVC Enrofloxacin-Selective Electrodes for Estimating Enrofloxacin in Pure Form and as Preparation Formula:

This study explored the development and qualities of the response of electrochemical properties of enrofloxacin-selective electrodes using precipitation based on producing phosphotungstic, after utilizing a matrix of polyvinyl chloride (PVC) and dibutyl phthalate or dibutyl phosphate as a plasticizer. The resulting membrane sensors were an enrofloxacin-phosphotungstic electrode (sensors 1) and an ENR-DOP-PTA electrode (sensors 2). Linear responses of (ENR-DBPH-PTA) and (ENR-DOP-PTA) within the concentration ranges of 2.1×10-6-10-1 and 3.0×10-6-10-2 mol. L-1, respectively, for both sensors were observed. Slopes of 51.61±0.24 and 39.40± 0.16 mV/decade and pH ranges equal to 2.5-8.5

... Show More
Scopus Crossref
View Publication Preview PDF
Publication Date
Thu Jun 30 2022
Journal Name
Iraqi Journal Of Laser
PDF Mechanical Properties of AISI 316L Stainless Steel Produced Via Selective Laser Melting

Abstract Additive manufacturing has been recently emerged as an adaptable production process that can fundamentally affect traditional manufacturing in the future. Due to its manufacturing strategy, selective laser melting (SLM) is suitable for complicated configurations. Investigating the potential effects of scanning speed and laser power on the porosity, corrosion resistance and hardness of AISI 316L stainless steel produced by SLM is the goal of this work. When compared to rolled stainless steel, the improvement is noticeable. To examine the microstructure of the samples, the optical microscopy (OM), scanning electron microscopy (SEM), and EDX have been utilized. Hardness and tensile strength were us

... Show More
View Publication Preview PDF
Publication Date
Fri Sep 24 2021
Journal Name
Indonesian Journal Of Chemistry
Molecular Imprinted of Nylon 6 for Selective Separation of Procaine by Solid-Phase Extraction

The study is based on the selective binding ability of the drug compound procaine (PRO) on a surface imprinted with nylon 6 (N6) polymer. Physical characterization of the polymer template was performed by X-ray diffraction and DSC thermal analysis. The imprinted polymer showed a high adsorption capacity to trap procaine (237 µg/g) and excellent recognition ability with an imprinted factor equal to 3.2. The method was applied to an extraction column simulating a solid-phase extraction to separate the drug compound in the presence of tinoxicam and nucleosimide separately and in a mixture of them with a recovery rate more than the presence of tinoxicam and nucleosimide separately and in a mixture of them with a recovery rate of more t

... Show More
Scopus (1)
Crossref (1)
Scopus Clarivate Crossref
View Publication
Publication Date
Sun Jan 01 2017
Journal Name
Analytical Methods
Determination of pharmaceuticals in freshwater sediments using ultrasonic-assisted extraction with SPE clean-up and HPLC-DAD or LC-ESI-MS/MS detection

A robust and sensitive analytical method is presented for the extraction and determination of six pharmaceuticals in freshwater sediments.

Scopus (19)
Crossref (17)
Scopus Clarivate Crossref
View Publication
Publication Date
Sun Dec 01 2013
Journal Name
Baghdad Science Journal
Flow injection analysis for the photometric determination of promethazine-HCl in pure and pharmaceutical preparation via oxidation by persulphate using Ayah 3SX3-3D solar micro photometer

The first flow injection spectrophotometric method is characterized by its speed and sensitivity which have been developed for the determination of promethazine-HCl in pure and pharmaceutical preparation. It is based on the in situ detection of colored cationic radicals formed via oxidation of the drug with sodium persulphate to pinkish-red species and the same species was determined by using homemade Ayah 3SX3-3D solar flow injection photometer. Optimum conditions were obtained by using the high intensive green light emitted diode as a source. Linear dynamic range for the absorbance versus promethazine-HCl concentration was 0-7 mmol.L-1, with the correlation coefficient (r) was 0.9904 while the percentage linearity (r2%) was 98.09%. the L.

... Show More
Crossref
View Publication Preview PDF
Publication Date
Fri Sep 25 2020
Journal Name
International Journal Of Drug Delivery Technology
Simultaneous Determination of Trace Mefenamic Acid in Pharmaceutical Samples via Flow Injection Fluorometry

Mefenamic acid belongs to non-steroidal anti-inflammatory drugs that are used widely for the treatment of analgesia. Our aim from this study is to establish a new assay for the quantitative determination of mefenamic acid (MFA) in the pharmaceutical sample by two sensitive and rapid flow injection-fluorometric methods. A homemade fluorometer was used in fluorescence measurements, which using solid-state laser diode 405 and 532 nm as a source, combined with a continuous flow injection technique. The first method depends on the effect of MFA on calcein blue (CLB) fluorescence at 405 nm. Another method is a study of rhodamine-6G (Rh-6G) fluorescence after adding MFA, and recording at 532 nm. Optimum parameters as fluorescent dye concen

... Show More
Scopus (5)
Crossref (4)
Scopus Crossref
View Publication
Publication Date
Wed Dec 05 2018
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Spectrophotometric Determination of Chlordiazepoxide in Pharmaceutical Formulations via Oxidative Coupling Reaction with Phenothiazine

Abstract

A sensitive, precise and reliable indirect spectrophotometric method for the determination of chlordiazepoxide (CDE) in pure and pharmaceutical dosage forms is described. The method is based on oxidative coupling reaction between amino group resulting from acidic decomposition of CDE with phenothiazine in the presence of sodium periodate to produce an intense green soluble dye that is stable and shows a maximum absorption at 602 nm. The calibration plot indicates that Beer’s law is obeyed over the concentration range of 0.1?50 µg/mL, with a molar absorptivity of 1×104 L/mol cm and correlation coefficient of 0.9994.All the conditions that affecting on the stability and sensitivity of the fo

... Show More
Scopus (2)
Scopus Crossref
View Publication Preview PDF