In this research, the mutual correlations between ionospheric parameters (MUF, OWF and LUF) have been suggested. The datasets of the MUF and OWF parameters have been generated using ASAPS international communication model, while the LUF parameter has been calculated using the REC533 model. The calculations have been made for the connection links between the capital Baghdad and many other locations that spread over the studied zone (Middle East region). The annual time of the years (2009 & 2014) of solar cycle 24 has been adopted to make the investigation in order to get the mutual correlation between ionospheric parameters. The test results of the annual correlation between ionospheric parameters showed that the mutual correlation between MUF & OWF is simple and can be represented by a linear regression equation, while the mutual correlations between (MUF & LUF), (OWF & LUF) can be represented by a fourth order polynomial equation (Quartic Polynomial Equation). The results of the conducted study showed that there was a good fit between ionospheric parameter values that have been generated using the suggested mutual correlation equation and the results generated from the international communication models and the international recommended criterion.
In this paper, a study was made to determine the properties of Jovian radio bursts emitted at frequency 20.1MHZ. The data were provided from the Radio Jove archive for twelve years (2000-2012) for multi stations. The duration time for Long bursts (L) was (10-30) seconds and for Short bursts (S) was (10-20) seconds. The effect of radio bursts from the Sun and the galactic background were calculated at the same frequency and were found that radio bursts from the Sun will reduce the occurrence probability of Jovian radio bursts much more than radio bursts from the galactic background. The distribution of Jovian radio bursts was different; the occurrence probability with respect to the northern latitudes was more than the southern latitudes.
The main goal of this paper is to make link between the subjects of projective
geometry, vector space and linear codes. The properties of codes and some examples
are shown. Furthermore, we will give some information about the geometrical
structure of the arcs. All these arcs are give rise to an error-correcting code that
corrects the maximum possible number of errors for its length.
In this research, two drugs were bonded through amide and ester attachment, using lactic acid as aspacer binder, produced di pro drug such as Procain and Ciprofloxacin. Since Procain has ailocail anesthetic action and Ciprofloxacin as antibacterial drug was reacted with lactic acid produced ester compound (1), then the carboxylic acid of lactic acid could reacted with free Procain oil produced amide attachment, the controlled drug release in different pH values at 37C˚was studied to improve their characteristic and to minimize the side effect of the drug could be used in broad spectrum activity as atherapeutic material.This mutual prodrug was used with another biological active drug instead of single action. The prepared prodrug was charac
... Show MoreBackground: Polycystic ovarian syndrome (PCOS) is a condition associated with chronic anovulation, and androgen excess. Clinically, PCOS women usually presents with menstrual irregularities, infertility, and hirsutism. Women with this syndrome are at increased risk of metabolic syndrome (MS).
Patients and Methods: This study was conducted during the period from March 2013 until the end of September 2013. A total of 50 PCOS women were studied (25 PCOS women with MS and 25 PCOS women without MS) with an age ranged from (35-45) years. Women with PCOS were referred to Medical City Hospital in Baghdad and compared with 25 healthy women as control group. Serum luteinizing hormone (LH), follicle
The appliance of milligauss meter was designed by Qusay Ismail to measure the induce of electromagnetic field for home appliance which are put at a distance from milligauss meter (15-30-60)cm .The results showed some appliance has recorded higher than normal acceptable level of electromagnetic radiation emissions and produced radiation of (350650)milligauss as for the rest of appliances has recorded values which are ranged between (1200)milligauss ,laptop was recorde radiation generally lower than from desktop and computer moniter (CRT).The radiation ,intensity decrease with increasing distance.
The study was conducted at the fields of the Department of Horticulture and Landscape Gardening, College of Agriculture, University of Baghdad " Abu Ghraib" during the growing seasons 2013-2014 to Evaluate the Vegetative growth , yield traits and genetic parameter of some tomato mutants. Results showed significantly increased of plant height in M6-2 mutant 245cm in Comparison with M6- 3 130 cm . M6-4 mutant significantly increasing of floral clusters 13 . Mutant M6-3 showed significantly increasing the average of, fruit weight 125.9g and plant yield 7.17 kg.plant-1 as comparison with M6-2 which showed decreasing of average of fruit weight and plant yield 79.40g and 4.38 kg.plant-1 respectively. Also results showed the highest Genetic variat
... Show MoreNon uniform channelization is a crucial task in cognitive radio receivers for obtaining separate channels from the digitized wideband input signal at different intervals of time. The two main requirements in the channelizer are reconfigurability and low complexity. In this paper, a reconfigurable architecture based on a combination of Improved Coefficient Decimation Method (ICDM) and Coefficient Interpolation Method (CIM) is proposed. The proposed Hybrid Coefficient Decimation-Interpolation Method (HCDIM) based filter bank (FB) is able to realize the same number of channels realized using (ICDM) but with a maximum decimation factor divided by the interpolation factor (L), which leads to less deterioration in stop band at
... Show MoreIn this work the diode planer magnetron sputtering device was
designed and fabricated. This device consists of two aluminum discs
(8cm) diameter and (5mm) thick. The distance between the two
electrodes is 2cm, 3cm, 4cm and 5cm.
Design and construction a double probe of tungsten wire with
(0.1mm) diameter and (1.2mm) length has been done to investigate
electron temperature, electron and ion density under different
distances between cathode and anode. The probes were situated in
the center of plasma between anode and cathode.
The results of this work show that, when the distance between
cathode and anode increased, the electron temperature decreased.
Also, the electron density increases with the increasing