This study deals with the shallow alluvial aquifer situated beneath the urban area of kirkuk city. The ancient part of the city (Shorja) is affected by seepage from local agricultural areas causing relatively high heavy metals concentration in groundwater. The selection of polluted site depended on the highest TDS value (3856 mg/L) associated with the highest heavy metal concentrations (Pb, Ni, Co and Zn) in groundwater. This study focuses on the evaluation of natural attenuation effectivity for long-term protection of groundwater quality using realistic three-dimensional reactive-transport groundwater model. The requirements of 3-dimensional reactive transport model were obtained from field observation and laboratory works, in addition to aquifer stratigraphy, minerology and hydrochemistry. The simulations were achieved by using PHAST program that is depended on the HST3D flow and transport code and the hydrochemical PHREEQC code. The modeling results explained the ability of natural attenuation in consuming the concentration of heavy metals, where Long-term (20 year) simulation results show that heavy metal adsorption on hydrous ferric oxide, effectively capture the movement of heavy metals in groundwater down gradient of source areas, resulting in an basically immobile groundwater plume.
The aim of this study is to the evaluation of the general hydrogeology condition of the Al-Khassa sub-basin area. Pumping test has been done for five wells in the area. The hydrogeological characteristics (transmissivity, hydraulic conductivity and storage coefficient) were determined in the area by input data which obtained from the pumping test process into the (AquiferWin32, Version 5) software program. The data were analyzed using Copper-Jacob, Theis and Hantuosh methods for pumping, the values of hydraulic characteristics range from: transmissivity (0.98 to 19.57) m²/day in (W7-W9-W10-W12) sites and 416 m²/day in W1, hydraulic conductivity (0.051 to 0.305) m/day in (W7-W9-W10-W12) sites and 5.012 m/day in W1, storage coefficie
... Show MoreThis paper aims to evaluate the hydraulic characteristics of the aquifer between Al-khassa dam and Kirkuk structure, Kirkuk/ NE Iraq. Pumping tests applied for selected wells in the area to evaluate the hydraulic characteristics of the aquifer, special distribution of the water table and groundwater movement direction of the groundwater, the hydraulic properties results of five single pumping test in the study area showed that the transmissivity (T) is ranged between (2.01 to 7. 5 m2/day ), storage coefficient (Sc) ranged (6.4 * 10-3 to 7.3 * 10-2) and the hydraulic conductivity (K) is ranged between (0.025 to 0.35 m/day) that calculated by Winlog software, groundwater discharge of the area is equal to
... Show MoreThe quality of groundwater should be improved by keeping safe water sources from contaminants in protective way by doing regular measuring and checkup before it supplied for usage. Private Wells do not receive the same services that wells supplying the public do. Well owners are responsible for protecting their drinking water. This work was carried out in Badra city, Iraq from December 2017 to May 2018, six wells water were investigated to determine the general characteristics of wells as well as studying the effect of environmental factors on the quality of water. The average of six wells were eleven parameters that is out of permissible limits were EC, Sal., Alk., TH, TDS, Na, Ca, Cl, SO4, Fe, Zn (4402-5183 /cm, 2.76-3.9 ppt
... Show MoreThe investigation of natural convection in an annular space between two concentric cylinders partially filled with metal foam is introduced numerically. The metal foam is inserted with a new suggested design that includes the distribution of metal foam in the annular space, not only in the redial direction, but also with the angular direction. Temperatures of inner and outer cylinders are maintained at constant value in which inner cylinder temperature is higher than the outer one. Naiver Stokes equation with Boussinesq approximation is used for fluid regime while Brinkman-Forchheimer Darcy model used for metal foam. In addition, the local thermal equilibrium condition in the energy e
Thirty-two soil samples were collected from the study area in October 2020 for geochemical and pollutants investigation of Shwan Sub-basin soil. All soil samples were analysed for different geochemical analyses. The analysis results revealed that the pH values in soil samples ranged from 7.12 to 7.56 with a mean of 7.327. According to the pH values detected in the soil samples, the soil is classified as neutral soil. The electrical conductivity ranged from 0.92 mmhos/cm to 7.8 mmhos/cm with a mean of 1.53 mmhos/cm. Thus, according to the detected electrical conductivity values, the soil was classified as non-saline to slightly saline. The organic matter ranged from 1.14% to 1.45% with a mean value of 1.326 %, while total organic
... Show MoreThe mass attenuation coefficient for beta particles through pure Polyvinyl chloride (PVC) and flax fibers- reinforced PVC composite were investigated as a function of the absorber thickness and the absorber to source distance. The beta particles mass attenuation coefficients were obtained using a NaI(Tl) energy selective scintillation counter with 90Sr/ 90Y beta source having an energy range from (0.546-2.275) MeV. Pure PVC polymer samples were prepared by compacting the PVC powder in a mould at high pressure (10bar) and temperature about 140°C for 30 minutes. A hot press system was used for this process. The experimentally obtained values of mass attenuation coefficients for 90Sr and 90Y were found to be 7.72 cm2.g-1and 0.842 cm2.g-1 r
... Show MoreThe Falluja residents had resorted to the underground water as an alternative to the surface waters of the Euphrates river passing near the city, through digging wells inside gardens of Mosques in the city during spring 2005. The present study aims to indicate the quality of these waters and demonstrates the extent of their suitability for drinking . For this purpose, 21 randomly distributed wells were chosen during August 2005. The water characters were measured ; the average values of 21 wells were as follows : Water temp .(22.6C ْ ◌ ) , EC (4,11 msem .\cm ), pH (7.15 ) and concentration of cations : Na (439mg\l) ;K (275mg\l) ; Li (0,28mg\l), Ba (15.2 mg\l) and (133mg\l). These character is ties were compared with the
... Show MoreIn this study, radon concentrations were measured in dwellings at specified locations in Baghdad city using ionization chamber radon monitor (ALPHA GUARD PQ2000 PRO). The measurements were carried out at different locations of these dwellings (living rooms, bed rooms, bath rooms, and kitchens). The results of the survey showed that the overall minimum, maximum average and mean average radon concentrations in dwellings were 5.77±0.73 Bq/m3, 23.27±13.57 Bq/m3, and 10.67±4.14 Bq/m3 respectively. The lowest average radon was found in (Ameryia) city, while the highest average radon concentration was found in (Kadmiya) city. Also, the results showed that the highest average radon concentration was found in the kitchens, while the lowest ave
... Show MorePolyethersulfone (PES) ultrafiltration membrane blending NaX zeolite crystals as a hydrophilic additive was examined for zinc (II) and lead ions Pb (II) removal from aqueous solutions. The effect of NaX zeolite content on the permeation flux and removal efficiency was studied. The results showed that adding zeolite to the polymer matrix enhanced the permeation flux. The permeation flux of all the zeolite/PES matrix membranes was higher than the pristine membrane. No significant improvement was observed in the removal of Zn (II) ions using all prepared membranes as the removal percentage did not raise above 29.2%. However, the removal percentage of Pb (II) ions was enhanced to 97% using a membrane containing 0.9%wt. zeolite. Also, it was
... Show More