Radon concentrations in dwellings of Baghdad city- Iraq
...Show More Authors

In this study, radon concentrations were measured in dwellings at specified locations in Baghdad city using ionization chamber radon monitor (ALPHA GUARD PQ2000 PRO). The measurements were carried out at different locations of these dwellings (living rooms, bed rooms, bath rooms, and kitchens). The results of the survey showed that the overall minimum, maximum average and mean average radon concentrations in dwellings were 5.77±0.73 Bq/m3, 23.27±13.57 Bq/m3, and 10.67±4.14 Bq/m3 respectively. The lowest average radon was found in (Ameryia) city, while the highest average radon concentration was found in (Kadmiya) city. Also, the results showed that the highest average radon concentration was found in the kitchens, while the lowest average radon concentration was found in the living rooms. The maximum annual effective dose in dwelling in Baghdad city in current study is 0.59 mSv.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Feb 20 2019
Journal Name
Iraqi Journal Of Physics
Measurement of radon concentrations for some houses in Al-Najaf city /Iraq
...Show More Authors

    Measurement of radon concentration level was carried out in 40 houses in Al – Najaf city during summer season of 2012. Long term measurement of indoor of old building radon concentrations have been taken, using a previously calibrated passive diffusion dosimeters containing CR – 39 solid state nuclear track detectors which are very sensitive for alpha particles. The measurement of the indoor radon concentration obtained in summer in these regions ranged from 11.654±4.216 Bq.m-3 to 53.610±8.777 Bq.m-3. The results were within universally permitted levels.     

View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Fri Jan 01 2021
Journal Name
Aip Conference Proceedings
Radon concentrations assessment in tap water for different areas in Baghdad city using Rad7
...Show More Authors

View Publication
Scopus (1)
Scopus Crossref
Publication Date
Sun Jan 13 2019
Journal Name
Iraqi Journal Of Physics
Measurements of radon, thoron and their progeny concentrations using twin cup dosimeter for indoor Al-Madaan city – Baghdad – Iraq
...Show More Authors

In this study, the activity concentrations of indoor radon, thoron
and their progeny have been measured in air for 61 different
locations of Al-Maddan city using twin cup dosimeter. Furthermore,
some useful parameters concerning the health hazards have been
estimated; working level month (WLM), annual effective dose (Eff),
and excess lung cancer per million person per year (ELC).The results
show that the values of radon gas levels in the investigated districts
varied from 56.28 to 194.43Bq/m3with an overall average value
132.96Bq/m3, while 0.313 to 1.085 for WLM with an overall average
0.740, respectively. The value of Eff and ELC have been found to
vary from 1.420 to 4.918 mSv/y with an overall average valu

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Wed Sep 12 2018
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Assessment of Radon Concentrations in the Soil of South Baghdad Suburbs
...Show More Authors

Measurements of radon gas concentrations were carried out for 12 soil samples at 3 sampling depths (surface, 5 cm and 10 cm) collected from (4) locations in south Baghdad suburbs (Bu'aitha) using solid state nuclear track detector CR-39 and sealed can technique. Radon concentrations for surface samples were ranged from 402.2 to 1538.4 Bq.m-3 with an average 994.4 Bq.m-3. Whereas, radon concentration was ranged from 813.1to 2050.4 Bq.m-3 and from 1309.8 to 4626. 1Bq.m-3 with an average values of 1359.8 Bq.m-3 and 2338.3 Bq.m-3 for 5 cm and 10 cm depths respectively. Maximum radon level was found at the location near to the river (site S4) while the minimum radon level was f

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Tue Sep 11 2018
Journal Name
Iraqi Journal Of Physics
Measurements of radon gas concentration in surface soil in Baghdad city
...Show More Authors

In the present work, radon gas concentrations in different surface soil samples in Baghdad governorate were measured using RAD-7 detector. The results have been shown that, the Radon gas concentrations ranged between (41.67±1.78Bq/m3), to (185.67±4.22Bq/m3), a map showing the distribution of the concentration of radon in selected areas was defined to identify areas with high pollution level. The reason for the high concentration of radon is that these surface soil samples are taken from agricultural areas. It is also known that fertilizers contain uranium levels as well as areas bombed in wars in the country. It is worth noting that all radon concentrations in Baghdad governorate are below the recommended minimum of 200-300Bq/m3) (Inte

... Show More
View Publication
Crossref
Publication Date
Wed Mar 29 2023
Journal Name
Aip Conference Proceedings
Measurement radon concentrations in samples for drinking water
...Show More Authors

The principal forms of radiation dosage for humans from spontaneous radiation material are being recognized as radon and its progenitors in the interior environment. Radiation-related health risks are caused by radon in water supply, which can be inhaled or ingested. Materials and Methods: The solid-state CR-39 nuclear trace detectors method was using in this research for measuring accumulation of radioactivity in water supply in different locations of Iraq's southwest corner of Baghdad. In Baghdad district, 42 samples were selected from 14 regions (3 samples out of each region) and put in dosimeters for 50 days. Results: The mean radon concentration was 49.75 Bq/m3, that is lower than the internationally recognized limit of 1100 Bq /m3. Th

... Show More
View Publication
Scopus Crossref
Publication Date
Mon Nov 09 2015
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
Variations Heavy Metals Concentrations in Tigris River in Baghdad City.: Variations Heavy Metals Concentrations in Tigris River in Baghdad City.
...Show More Authors

The aim of the research is the detection of heavy metals using (Inductively coupled Plasma ICP) for samples in Tigris river at intakes of water treatment plants Baghdad (Sharq dejla, Al-Wathba, Al-Wahda, and Al-Dora) and samples at Tigris banks near (Al-Adhamya, Al-Shuhda bridge and al-Jadrya).
All the recorded results were fitted with Iraqi standers No. 25 in 1967 for all samples with heavy metals (arsenic Ar, Cadmium Cd, Chromium Cr, Zinc Zn, Lead Pb, Copper Cu, Nickel Ni, Manganese Mn, Ferrous Fe) where all concentration were lower than standard values except Cadmium (0.01- 0.014) in plants intakes and (0.027- 0.048) in river samples while the standard value is (0.005).
Other tests such as chemical oxygen demand and oil &

... Show More
View Publication Preview PDF
Publication Date
Tue Jan 11 2022
Journal Name
Iraqi Journal Of Science
Radon Gas Concentration Measurement in Air of Al - Haswaa City in Province of Baghdad
...Show More Authors

Abstract
In this study the radon gas concentration in air in Al - Haswaa city in province of Baghdad in Iraq have been calculated using CR-39 solid–state nuclear track detector technique. A total of 8 samples selected from 8 region in Al – Haswaa city in province of Baghdad have been placed in the dosimeters for 30 day. The average radon gas concentration was found to be 486.26 Bq/m3 which is lower than the standard international limit (1100 Bq/m3). The potential alpha energy concentration and annual effective dose have been calculated. A proportional relationship between the annual effective dose and radon gas concentration within the studied region has been certified.

View Publication Preview PDF
Publication Date
Thu Oct 14 2021
Journal Name
Iraqi Journal Of Physics
Measurement of radon and thoron concentrations of soil- gas in Al-Kufa city using RAD-7 detector
...Show More Authors

This work represents the set of measurements of radon and thoron concentrations levels of soil-gas in Al-Kufa city in Iraq using electric Radon meter (RAD-7). Radon and thoron concentration were measured in soil-gas in 20 location for three depth of (50, 100 and 150) cm.
The results show that the emanation rate of radon and thoron gas varied from location to anther, depending on the geological formation. The Radon concentration in soil has been found to vary from (12775±400) Bq/m3 at 150 cm depth in location (sample K2) to (41.45±17) Bq/m3, for depth 150 cm in location (sample K20). The thoron concentration in soil has been found to vary from (198±8.5) Bq/m3 at 150 cm depth in location samples (K1 & K2) to undetected in the mos

... Show More
View Publication Preview PDF
Publication Date
Tue Jan 30 2018
Journal Name
Iraqi Journal Of Science
Determine the Radon Gas Level Using the GIS Technique for Baghdad City
...Show More Authors

In this work, radon concentrations in the polluted environment were measured within the Baghdad sample surface soil conservation, and this was done using a RAD-7 mobile detector. The work consists of four parts:
The first part includes calculating the latitude and longitude of each point of the study area using the Global Positioning System (GPS). The second part of which includes Determination of 222Rn gas concentrations in surface soil samples. In the northeast part of Baghdad, the highest concentration of radon was found in Al-
Shaab area (3.11 ±175.33 Bq / m3), while the lowest gas concentration in AL Gzeera area (6.67±73.00 Bq/ m3), In the northwest part of Baghdad, the highest concentratio

... Show More