Preferred Language
Articles
/
ijs-6909
Determination of the shape for (54Xe and 82pb) nuclei from deformation parameters ( , )

The shape for even-even (54Xe 118≤ A ≤ 140 and 82Pb 204 ≤ A ≤ 210 ) nuclei have been studied and investigated through the deformation parameters and δ , these deformation parameters were calculated by two different methods. The first one is nucleus quadrupole deformation parameter β2 from reduced transition probability B(E2)↑ for 0+→2+1 transitions and the second is nucleus quadrupole deformation parameters δ from quadrupole moment Qo.The relationship between two deformation parameters ( , ) and neutrons magic number (N=82 & 126) was studied through plotting the deformation parameters ( , ) as a function of neutrons number , from this relationship we can see very cleary that the deformation of nucleus decreased when the neutrons number approaches to magic number.
In the present work, another relationship was studied, this was the relationship between two deformation parameters and which is obtained by getting the ratio of / . To achieve our mean purposes (determine the nuclear shape from deformation parameters) and come to a decision if the nucleus under the study has prolate , oblate or spherical shape through calculating the minor and major ellipsoid axises (a ,b) and plotted the nucleus shape depending on the value of (a ,b).

View Publication
Publication Date
Thu Nov 05 2020
Journal Name
Methods And Objects Of Chemical Analysis
Derivative Spectrophotometric Determination for Simultaneous Estimation of Isoniazid and Ciprofloxacin in Mixture and Pharmaceutical Formulation

A simple analytical method was used in the present work for the simultaneous quantification of Ciprofloxacin and Isoniazid in pharmaceutical preparations. UV-Visible spectrophotometry has been applied to quantify these compounds in pure and mixture solutions using the first-order derivative method. The method depends on the first derivative spectrophotometry using zero-cross, peak to baseline, peak to peak and peak area measurements. Good linearity was shown in the concentration range of 2 to 24 µg∙mL-1 for Ciprofloxacin and 2 to 22 µg∙mL-1 for Isoniazid in the mixture, and the correlation coefficients were 0.9990 and 0.9989 respectively using peak area mode. The limits of detection (LOD) and limits of quantification (LOQ) were

... Show More
Publication Date
Sat Mar 28 2020
Journal Name
Iraqi Journal Of Science
Least Squares Estimations for the General Linear Model Parameters with Epsilon Skew Normal Error Term

Examination of skewness makes academics more aware of the importance of accurate statistical analysis. Undoubtedly, most phenomena contain a certain percentage of skewness which resulted to the appearance of what is -called "asymmetry" and, consequently, the importance of the skew normal family . The epsilon skew normal distribution ESN (μ, σ, ε) is one of the probability distributions which provide a more flexible model because the skewness parameter provides the possibility to fluctuate from normal to skewed distribution. Theoretically, the estimation of linear regression model parameters, with an average error value that is not zero, is considered a major challenge due to having difficulties, as no explicit formula to calcula

... Show More
Scopus Crossref
View Publication Preview PDF
Publication Date
Sun Jan 20 2019
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Bayesian Estimation for Two Parameters of Gamma Distribution Under Precautionary Loss Function

In the current study, the researchers have been obtained Bayes estimators for the shape and scale parameters of Gamma distribution under the precautionary loss function, assuming the priors, represented by Gamma and Exponential priors for the shape and scale parameters respectively. Moment, Maximum likelihood estimators and Lindley’s approximation have been used effectively in Bayesian estimation.

Based on Monte Carlo simulation method, those estimators are compared depending on the mean squared errors (MSE’s). The results show that, the performance of Bayes estimator under precautionary loss function with Gamma and Exponential priors is better than other estimates in all cases.

Crossref (5)
Crossref
View Publication Preview PDF
Publication Date
Wed Mar 01 2023
Journal Name
Journal Of Applied Spectroscopy
Spectrophotometric Method for the Determination of Naphazoline Nitrate in Bulk and Pharmaceutical Preparations by Using 1,2-Naphthoquinone-4-Sulfonate

A simple, accurate, and cost-efficient UV-Visible spectrophotometric method has been developed for the determination of naphazoline nitrate (NPZ) in pure and pharmaceutical formulations. The suggested method was based on the nucleophilic substitution reaction of NPZ with 1,2-naphthoquinone-4-sulfonate sodium salt in alkaline medium at 80°C to form an orange/red-colored product of maximum absorption (λmax) at 483 nm. The stoichiometry of the reaction was determined via Job's method and limiting logarithmic method, and the mechanism of the reaction was postulated. Under the optimal conditions of the reaction, Beerʼs law was obeyed within the concentration range 0.5–50 μg/mL, the molar absorptivity value (ε) was 5766.5 L × mol–1 × c

... Show More
Scopus
Publication Date
Wed Mar 01 2023
Journal Name
Journal Of Applied Spectroscopy
Scopus Clarivate Crossref
View Publication
Publication Date
Sun Apr 30 2023
Journal Name
Iraqi Journal Of Science
Batch and Flow Injection Spectrophotometric Methods for the Determination of Clonazepam in Pharmaceutical Preparations via Oxidative Coupling with Pyrocatechol

A simple, fast, and sensitive batch and flow injection spectrophotometric
methods have been developed for the determination of clonazepam(CZP) in pure
form and in pharmaceutical preparations. The proposed methods are based on the
oxidative coupling reaction of the reduced clonazepam using Zn powders and conc.
HCl with payrocatechol and in the presence of ferric sulphate. The resulting reddish
colored product had a maximum absorbance at 515 nm. The optimum reaction
conditions and other analytical parameters have been evaluated . The linear ranges
for the batch and FI methods determination of CZP were 0.5-32, 50-400 μg mL-1
and the detection limits were 0.193, 22.60 μg mL-1 for both methods respectively.
Statis

... Show More
View Publication Preview PDF
Publication Date
Tue Mar 26 2019
Journal Name
Iraqi Journal Of Science
Study the Effect Some of Electrodeposition Parameters on Wear Resistance for Cu-MWCNT Composite Coating

A Copper- Mullet walled Carbon Nanotube Cu/MWCNT composite coatings prepared by direct and pulse electrodeposition with various contents of MWCNT particles, using electrodeposition method from acidic sulfate bath. The effect of the current density, pulse frequency and  particle loading (PL) of MWCNT particle in the electrolyte on the morphology and volume fraction Vol% of MWCNT in deposit were investigate. The experimental results indicated that the depositing condition affect on the microstructure of deposited copper and MWCNT Vol% in deposit. Also, the Vol% of MWCNT increases in deposit with particle loading (PL) increasing in the bath and increased with increased current density. Increasing MWCNTs in electrolyte produced increase

... Show More
View Publication Preview PDF
Publication Date
Fri Aug 01 2008
Journal Name
2008 International Symposium On Information Technology
Scopus (21)
Crossref (17)
Scopus Crossref
View Publication
Publication Date
Wed Jun 28 2023
Journal Name
The Iraqi Journal Of Veterinary Medicine
Hematological Parameters as Indicators for Litter size and Pregnancy Stage in Awassi ‎Ewes

Physiological status and litter size can indeed have a significant impact on ewes' ‎hematological parameters, which are essential indicators of their health. Therefore, this study ‎examined the hematological profiles of ewes during pregnancy with single and twins in the ‎Awassi ewes. The present study involved 232 ewes in good health and at sexual maturity. ‎Among them, 123 ewes had single pregnancies, while 109 ewes had twin pregnancies. The age ‎range of the ewes included in the study was between 3.5 and 4.5 years. Hematological tests ‎were conducted on the sheep's blood samples promptly following collection. The findings ‎demonstrated variations in hematological parameters among pregnant

... Show More
Crossref (1)
Crossref
View Publication
Publication Date
Tue Feb 28 2023
Journal Name
Iraqi Journal Of Science
Calculating Parameters for Se and Tin Plasmas Produced by Pulsed Nd: YAG Laser

      In this study, the plasma formed by the preparation of Se and Tin (Sn) using a Nd: YAG laser with a wavelength of 1064 nm in air, which was then studied using the technique of optical emission spectrum, was presented (OES).The laser-induced plasma parameters such an electron temperature (Te) were identified using two-ratio methods, using Stark broadening methods to determine the density of electrons (ne). According to the findings, there is a correlation between the amount of laser energy that is applied and the increase in the emission intensity of the spectral lines. In the case of Se plasma, an increase in laser energy causes a rise in the temperature of the electrons. While increasing the temperature of the elec

... Show More
Scopus Crossref
View Publication Preview PDF