Preferred Language
Articles
/
ijs-6327
Noise Reduction and Gestational Age Estimation for Ultrasound Fetuses Images.
...Show More Authors

Ultrasound imaging is often preferred over other medical imaging modalities because it is non-invasive, non-ionizing, and low-cost. However, the main weakness of medical ultrasound image is the poor quality of images, due to presence of speckle noise and blurring. Speckle is characteristic phenomenon in ultrasound images, which can be described as random multiplicative noise that occurrence is often undesirable, since it affects the tasks of human interpretation and diagnosis. Blurring is a form of bandwidth reduction of an ideal image owing to the imperfect image formation process. Image denoising involves processing of the image data to produce a visually high quality image. The denoising algorithms may be classified into two categories, spatial filtering algorithms and transform domain based algorithms. In this work three adaptive filters are used to denoising speckle noise in ultrasonic (B-mode) images based on calculating the Mean Square Error (MSE) and Peak Signal to Noise Ratio (PSNR) value as a metric is presented, then estimated the gestation age from filtered images using MATLAB program, as well as using Wiener filter to restore the degradation images.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Mar 02 2008
Journal Name
Baghdad Science Journal
Calculations of Signal to Noise Ratio (SNR) for Free Space Optical Communication Systems
...Show More Authors

In this paper, we calculate and measure the SNR theoretically and experimental for digital full duplex optical communication systems for different ranges in free space, the system consists of transmitter and receiver in each side. The semiconductor laser (pointer) was used as a carrier wave in free space with the specification is 5mW power and 650nm wavelength. The type of optical detector was used a PIN with area 1mm2 and responsively 0.4A/W for this wavelength. The results show a high quality optical communication system for different range from (300-1300)m with different bit rat (60-140)kbit/sec is achieved with best values of the signal to noise ratio (SNR).

View Publication Preview PDF
Crossref
Publication Date
Mon Jul 04 2022
Journal Name
Indian Journal Of Forensic Medicine & Toxicology
The Correlation between Insulin Resistance and Urotensin II in Patients with Gestational Diabetes Mellitus
...Show More Authors

Gestational diabetes mellitus is glucose intolerance of varying degree with onset or first detection duringpregnancy,it can causelong and short term morbidities in both the mother and the child, such as shoulder dystocia,preeclampsia, and high blood pressure. The most powerful endogenous vasoconstrictor peptide, urotensin II, andits receptor are involved in the etiology of gestational diabetes mellitus.Aim of the study: The study’s goal was to see if there is a link between Urotensin II levels and insulin resistancein pregnant women with gestational diabetes.Patients and method: A case-control study that was conducted in obstetrics and gynecology department atBaghdad Teaching hospital from the first of January 2019 to the end of D

... Show More
Preview PDF
Crossref
Publication Date
Thu Jan 01 2015
Journal Name
International Journal Of Advanced Research In Computer Science And Software Engineering
Distinguishing Cartoons Images from Real –Life Images
...Show More Authors

Publication Date
Thu Sep 01 2022
Journal Name
Journal Of Engineering
Design and Implementation of Active Noise Cancellation for Car Cabin on Sulaimania Roads Using Arduino Embedded System
...Show More Authors

Car drivers hear many kinds of noise inside their vehicles' cabins, and the most annoying ones are the noise generated by tires, engines, and outside winds. Noise affects the comfort of the passengers inside the cabin, and it’s sad to say that modern cars are noisier in many kinds of noise signals due to using a lot of plastic materials in new budget cars. For expensive and luxury cars, the problem is solved by using better sound insulation materials, but for the budget ones, the approach used here is effective. It is called Active Noise Cancellation and can be done using analog or digital electronics. An operational amplifier and filters are used for the analog one, and in the digital one, signal processor chips are used. In engineeri

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Jan 01 2013
Journal Name
Iraqi Journal Of Physics
A comparison between PCA and some enhancement filters for denoising astronomical images
...Show More Authors

This paper includes a comparison between denoising techniques by using statistical approach, principal component analysis with local pixel grouping (PCA-LPG), this procedure is iterated second time to further improve the denoising performance, and other enhancement filters were used. Like adaptive Wiener low pass-filter to a grayscale image that has been degraded by constant power additive noise, based on statistics estimated from a local neighborhood of each pixel. Performs Median filter of the input noisy image, each output pixel contains the Median value in the M-by-N neighborhood around the corresponding pixel in the input image, Gaussian low pass-filter and Order-statistic filter also be used. Experimental results shows LPG-PCA method

... Show More
Publication Date
Wed Feb 20 2019
Journal Name
Iraqi Journal Of Physics
A comparison between PCA and some enhancement filters for denoising astronomical images
...Show More Authors

This paper includes a comparison between denoising techniques by using statistical approach, principal component analysis with local pixel grouping (PCA-LPG), this procedure is iterated second time to further improve the denoising performance, and other enhancement filters were used. Like adaptive Wiener low pass-filter to a grayscale image that has been degraded by constant power additive noise, based on statistics estimated from a local neighborhood of each pixel. Performs Median filter of the input noisy image, each output pixel contains the Median value in the M-by-N neighborhood around the corresponding pixel in the input image, Gaussian low pass-filter and Order-statistic filter also be used.

Experimental results shows LPG-

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Apr 03 2016
Journal Name
Journal Of The Faculty Of Medicine Baghdad
Ultrasound findings in prediction of breast cancer histological grade and HER2 status
...Show More Authors

Background: Breast cancer is the most frequent cancerous tumor and major cause of death from cancer between women all over the world.
Objectives: is to assess if ultrasound features of breast cancer can predict its histopathological grade and HER2 status of breast cancer for patients had their diagnosis in Oncology Teaching Hospital in Medical city complex from September 2014 to November 2015
Patients and Methods: This is retrospective study of 102 patients whom histopathologically proved breast cancer had reviewed their ultrasound findings and correlate them with histopathological grade and HER2 status.
Results: well circumscribed lesions, poorly defined and spiculated lesions are more likely to be of intermediate to high grade

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Jan 02 2014
Journal Name
Journal Of The Faculty Of Medicine Baghdad
The value of ultrasound to differentiate between benign and malignant duct ectasia
...Show More Authors

Background: Mammary duct ectasia is defined as dilated duct larger than 2 mm in diameter seen in fibrocystic changes, ductal epithelial hyperplasia, papiloma, DCIS. US has a significant role in diagnostic breast imaging. It is most commonly used as an adjunctive test in characterizing lesions detected by other imaging modalities or by clinical examination

Objective: This study was designed to investigate differences in ultrasonographic findings between malignant and benign mammary duct ectasia.

Patients and Methods: From November 2010 to July 2011, 100 womem with mammary duct ectasia lesions depicted on sonograms were included in this study. We evaluated the ultrasonograp

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Jan 01 2018
Journal Name
Indian Journal Of Public Health Research & Development
Histopathological alternations of placenta in pregnancy women complicated with gestational diabetes
...Show More Authors

View Publication
Scopus (1)
Crossref (2)
Scopus Crossref
Publication Date
Mon Feb 18 2019
Journal Name
Iraqi Journal Of Physics
Derivative of an image that corrupted by additive noise
...Show More Authors

In this paper the behavior of the quality of the gradient that implemented on an image as a function of noise error is presented. The cross correlation coefficient (ccc) between the derivative of the original image before and after introducing noise error shows dramatic decline compared with the corresponding images before taking derivatives. Mathematical equations have been constructed to control the relation between (ccc) and the noise parameter.

View Publication Preview PDF
Crossref