Preferred Language
Articles
/
ijs-5636
Influence of Distance and Argon Flow rate on Pseudomonas aeruginosa Bacteria Exposed to Non thermal Plasma at Atmospheric Pressure

     In this research, a type of gram negative bacteria was exposed to non-thermal plasma at a distance of (2 and 3 cm) from the plasma flow nozzle, with the use of an alternating power supply (5KHz), where exposure was made at two different voltages (4.9 and 8 kV). A negative gram of Pseudomonas aeruginosa bacteria was isolated and exposed to non-thermal plasma at different flow rates of argon gas whose value ranged from (1-5) liters/minute. The results showed that bacterial killing rate is directly proportional to distance while exposing the samples to non-thermal plasma, and the best factors by which a complete killing rate was obtained were at a distance of 2 cm with a voltage of 8 kV and a gas flow rate of 5 liters/min, while complete killing of bacteria was not achieved at a distance of 3 cm where the percentage was 95% at the same argon gas flow rate.

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Apr 23 2018
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Detection of tox A gene in Pseudomonas aeruginosa that isolates from different clinical cases by using PCR.

       Current study obtained (75) isolate of Pseudomonas aeruginosa collected from different cases included : 28 isolates from otitis media, 23 isolates from burn infections, 10 isolates from wound infections, 8 isolates from urinary tract infections and 6 isolates from blood, during the period between 1/9/2014 to 1/11/2014

       The result revealed that the tox A gene was present in 54 isolates (72%) of Pseudomonas aeruginosa. The gel electrophoresis showed that the molecular weight of tox A gene was 352 bp. The result shows 17 isolates (60.71%) from otitis media has tox A gene, 1

... Show More
Crossref (1)
Crossref
View Publication Preview PDF
Publication Date
Fri Oct 01 2010
Journal Name
Iraqi Journal Of Physics
Analysis of Initiation and Growth of Plasma Channels Within Non-Mixed Dielectric Liquids

Pre-breakdown phenomenon was investigated within the two, non-mixed dielectric liquids; transformation oil and cresol. Finite element technique was used to follow the initiation and growth of plasma channels (streamer discharge) within pin-plane configuration. That was done for different spacing between the pin-electrode and the liquid-liquid interface. Streamer growth model assumed that, the streamer initiation occurs at the region of the highest value of electric field. Our study shows that the streamer initiates at the tip of the pin and growths toward the other electrode. The study shows, too, that the streamer path controlled by the difference of permittivity of the two liquids and spacing distance of the liquid-liquid interface fro

... Show More
View Publication Preview PDF
Publication Date
Thu Jun 30 2022
Journal Name
Iraqi Journal Of Science
Plasma Properties of a Low-Pressure Hollow Cathode DC Discharge

      The current study involves an experimental investigation of plasma main parameters of a DC discharge with a hollow cathode (HCD) geometry in air using apertures of different diameters from the hollow cathode (1, 1.5, 2, and 2.5 cm). A tiny Langmuir probe is used to investigate the plasma properties. The HCD was operated at constant power of 12.4 W and gas pressures ranging between 0.1 to 0.8 torr. It was observed that the operational conditions strongly affect the electron temperature and density, while the hollow cathode diameter has not much influence. The main important observation was that at relatively high air pressure (>0.4 torr) two electron temperatures were obtained, while at relatively low pressure (<0.4 torr)

... Show More
Scopus Crossref
View Publication Preview PDF
Publication Date
Mon May 20 2019
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Investigation in the Effect of Applied Voltage and Working Pressure on Some Plasma Parameters in the Positive Column of Dc Glow Discharge

     Comsol multiphysics software is established to make a simulation that is comparable with experimental device. by utilizing comsol, the positive column domain of direct-current glow discharge with argon is considered for both of different applied voltage and working gas pressure. The calculations are exhibited by using a precise collision cross sections and Townsend coefficients for the argon. The impacts of voltage and pressure on the Debye length, number of particles in Debye sphere and plasma frequency are calculated and graphically delineated. With this regard to the dependence of plasma parameters on the applied voltage and pressure, some of them are found to be compatible with the experimental

... Show More
Crossref (1)
Crossref
View Publication Preview PDF
Publication Date
Thu Jan 02 2014
Journal Name
Journal Of The Faculty Of Medicine Baghdad
Morning blood pressure surge and dipping profile in non-hypertensive obese subjects.

Background: Obesity is an evolving major health problem in both developed and developing countries. Non-hypertensive obese may have an elevated Morning Blood pressure surge (MBPS), which is associated with increased risk for cardiac events (CE) independently of office and ambulatory blood pressure (BP). Non-hypertensive obese also may have a blunted nocturnal decrease in BP during the night, while healthy normotensive non-obese individuals have a 10%–20% nocturnal decrease in blood pressure (BP) during the night or dipping. Thus, 24-hour ambulatory blood pressure monitor (ABPM) is the gold standard to evaluate MBPS and dipping profile in non-hypertensive obese individuals.

Objectives:&nbsp

... Show More
Crossref
View Publication Preview PDF
Publication Date
Thu Oct 07 2021
Journal Name
Rimak International Journal And Humanities And Social Sciences
Publication Date
Sat Oct 30 2021
Journal Name
Iraqi Journal Of Science
Occurrence of Point Mutations in gyrA and parC Genes of Ciprofloxacin-Resistant Pseudomonas aeruginosa Isolated from Burn Infections

     The spread of antibiotic resistant bacteria is a worldwide problem. Due to the importance of P. aeruginosa as a multidrug resistant bacterium, this study aimed, through molecular techniques, to detect point mutations in chromosomal genes responsible for the quinolones class of antibiotics resistance. A total of 52 isolates from burn infections were identified using specific primers for P. aeruginosa 16S rDNA. Ciprofloxacin minimum inhibitory concentrations (MIC) were estimated using the agar dilution assay. DNA sequences of the quinolone resistance-determining regions of gyrA and parC were determined for detecting the mutations found in these genes and the relations among the i

... Show More
Scopus (1)
Crossref (1)
Scopus Crossref
View Publication Preview PDF
Publication Date
Wed Aug 31 2022
Journal Name
Iraqi Journal Of Science
Influence of Cylindrical Electrode Configuration on Plasma Parameters in a Sputtering System

      In the present work, the effect of the cylindrical configurations of the sputtering device electrodes on the plasma parameters (Debye length, electron temperature, electron density, plasma frequency) is studied. Also, the effect of the argon gas pressure on the discharge properties is examined with gas pressures of (0.08, 0.2, 0.4 and 0.6) Torr. The properties of the plasma are diagnosed by optical emission spectrometry. The spectroscopic method is adopted for examining the atomic spectra of argon emission.  The electron temperature is determined by the Boltzmann method. While, the Stark-widening method was employed for calculating the electron number density. The voltage against current curves of the cylindrical sprayer disc

... Show More
Scopus (6)
Crossref (2)
Scopus Crossref
View Publication Preview PDF
Publication Date
Sun Mar 01 2015
Journal Name
Current Research In Microbiology And Biotechnology
Evaluation for the Cytotoxic Effect of Exotoxin A Produced by Pseudomonas aeruginosa on Mice by using Cytogenetic Parameters

This research was conduct to evaluate the cytotoxic effect of exotoxin A (ETA) produced by Pseudomonas aeruginosa on mice in comparison with (phosphate buffer saline (PBS) as a negative control. The effect of the toxin was measured by employing the cytogenetic analysis which included (the mitotic index (MI), chromosomal aberrations (CAs), micronucleus (MN) and sperm abnormalities) parameters. In order to specify the cytotoxic effect of the toxin, three doses of ETA (125, 250 and 500 ng/ml) were used. Results showed that ETA was found to cause a significant decrease in mitotic index (MI) percentage, while significant increase in micronucleus (MN), chromosomal aberrations (CAs) and sperm abnormalities parameters in compression with control wa

... Show More
Publication Date
Sun Mar 04 2018
Journal Name
Iraqi Journal Of Science
Effects of RVLM Stimulation on Blood Pressure and Vasopressin-Like Levels in Brain Sites and Plasma are an Anesthetic Dependent. Rashid IH

The study is sought to determine specific alteration in AVP-LI level of plasma and sites of the hypothalamic-neurohypophysial-system; supraoptic nucleus (SON), paraventricular nucleus (PVN), neurointermediate lobe (NIL), and median eminence (ME), related to effects of stress of different anesthetics and electrical stimulation of RVLM/C1area. Urethane or halothane anesthetized Wistar rats were subjected to intra-RVLM electrical stimulation of 10 sec train, 1msec pulse duration at 40 Hz, and 2V every 30s.  After 30min stimulation, AVP-LI extracted from plasma, NIL, ME, SON, and PVN and measured by RIA, were compared with that of sham-stimulated urethane- or halothane-anesthetized rats and unstimulated unanesthetized control rats. Data

... Show More
View Publication Preview PDF