Medical Ultrasound (US) has many features that make it widely used in the world. These features are safety, availability and low cost. However, despite these features, the ultrasound suffers from problems. These problems are speckle noise and artifacts. In this paper, a new method is proposed to improve US images by removing speckle noise and reducing artifacts to enhance the contrast of the image. The proposed method involves algorithms for image preprocessing and segmentation. A median filter is used to smooth the image in the pre-processing. Additionally, to obtain best results, applying median filter with different kernel values. We take the better output of the median filter and feed it into the Gaussian filter, which then feeds the output of the Gaussian filter into histogram equalization to improve image visualization. The segmentation is done by thresholding and region growing segmentation. The value of threshold 128 was found to be better after we tested many values of thresholding. This value of thresholding combined with region growing gave accurate result segmentation of images. This paper demonstrates how image noise, artifacts and techniques were used effectively to improve image quality, and the analysis of performance of various techniques.
Recently digital mammography is most widely used technology for early detection of breast cancer. The main diagnosing elements such as lesion or masses in digital mammograms are with law contrast. The purpose of this paper is to enhance the mammogram images by increasing its contrast. Different enhancement method are used for this purpose such as histogram equalization (HE), Contrast Limited Adaptive Histogram Equalization (CLAHE), Morphological, and Retinex. The Retinex method also implement by combining it with HE once, and with CLAHE to improve its performance. The experimental results show that using Retinex with CLAHE can produce an image with enhancement in contrast better than using it with HE method and better than other methods
... Show MoreGroupwise non-rigid image alignment is a difficult non-linear optimization problem involving many parameters and often large datasets. Previous methods have explored various metrics and optimization strategies. Good results have been previously achieved with simple metrics, requiring complex optimization, often with many unintuitive parameters that require careful tuning for each dataset. In this chapter, the problem is restructured to use a simpler, iterative optimization algorithm, with very few free parameters. The warps are refined using an iterative Levenberg-Marquardt minimization to the mean, based on updating the locations of a small number of points and incorporating a stiffness constraint. This optimization approach is eff
... Show MoreThe rapid development of telemedicine services and the requirements for exchanging medical information between physicians, consultants, and health institutions have made the protection of patients’ information an important priority for any future e-health system. The protection of medical information, including the cover (i.e. medical image), has a specificity that slightly differs from the requirements for protecting other information. It is necessary to preserve the cover greatly due to its importance on the reception side as medical staff use this information to provide a diagnosis to save a patient's life. If the cover is tampered with, this leads to failure in achieving the goal of telemedicine. Therefore, this work provides an in
... Show MoreDisease diagnosis with computer-aided methods has been extensively studied and applied in diagnosing and monitoring of several chronic diseases. Early detection and risk assessment of breast diseases based on clinical data is helpful for doctors to make early diagnosis and monitor the disease progression. The purpose of this study is to exploit the Convolutional Neural Network (CNN) in discriminating breast MRI scans into pathological and healthy. In this study, a fully automated and efficient deep features extraction algorithm that exploits the spatial information obtained from both T2W-TSE and STIR MRI sequences to discriminate between pathological and healthy breast MRI scans. The breast MRI scans are preprocessed prior to the feature
... Show MoreNowadays, the advances in information and communication technologies open the wide door to realize the digital world’s dream. Besides, within the clear scientific scope in all fields, especially the medical field, it has become necessary to harness all the scientific capabilities to serve people, especially in medical-related services. The medical images represent the basis of clinical diagnosis and the source of telehealth and teleconsultation processes. The exchange of these images can be subject to several challenges, such as transmission bandwidth, time delivery, fraud, tampering, modifying, privacy, and more. This paper will introduce an algorithm consisting a combination of compression and encryption techniques to meet such chall
... Show MoreThe coronavirus is a family of viruses that cause different dangerous diseases that lead to death. Two types of this virus have been previously found: SARS-CoV, which causes a severe respiratory syndrome, and MERS-CoV, which causes a respiratory syndrome in the Middle East. The latest coronavirus, originated in the Chinese city of Wuhan, is known as the COVID-19 pandemic. It is a new kind of coronavirus that can harm people and was first discovered in Dec. 2019. According to the statistics of the World Health Organization (WHO), the number of people infected with this serious disease has reached more than seven million people from all over the world. In Iraq, the number of people infected has reached more than tw
... Show MoreSecurity concerns in the transfer of medical images have drawn a lot of attention to the topic of medical picture encryption as of late. Furthermore, recent events have brought attention to the fact that medical photographs are constantly being produced and circulated online, necessitating safeguards against their inappropriate use. To improve the design of the AES algorithm standard for medical picture encryption, this research presents several new criteria. It was created so that needs for higher levels of safety and higher levels of performance could be met. First, the pixels in the image are diffused to randomly mix them up and disperse them all over the screen. Rather than using rounds, the suggested technique utilizes a cascad
... Show MoreThis research involves studying the influence of increasing the
number of Gaussian points and the style of their distribution, on a circular exit pupil, on the numerical calculations accuracy of the point spread function for an ideal optical system and another system having focus error of (0.25 A. and 0.5 A. )
It was shown that the accuracy of the results depends on the type of
distributing points on the exit pupil. Also, the accuracy increases with the increase of the number of points (N) and the increase of aberrations which requires on increas (N).