Thirty-three samples of groundwater were taken from Dibdibba unconfined aquifer in the Zuber area southwestern parts of Basrah governorate south of Iraq to assess the groundwater quality. A statistical multivariate analysis was done using cations and anions, pH, total dissolved solids (TDS), and electrical conductivity (EC) that were measured for drinking, livestock, and construction purposes. Residual sodium bicarbonate (RSBC), Magnesium Ratio (MR), and Permeability index (PI) were used to evaluate the suitability of the present samples for irrigation activity. The quality of groundwater in the study area is unsuitable for drinking water, industrial and building uses. But it is suitable for livestock uses, According to Residual Sodium Carbonate and Magnesium Ratio the groundwater in the study area are suitable for irrigation purposes, but unsuitable for Permeability index. Multivariate analysis results indicate the high positive correlation between Ec and TDS with other constituents, two significant clusters I and II are obtained with significant Ec and TDS responsible for playing the most effective in classifying the present samples. 71.85% and l2.21% of the present of the total variance of the groundwater samples were explained by Factor analyses, Factor I indicated increasing Cl-, Mg+2, Na+, and Ca+2 with the highest weight and Factor II show lower weight average of K+ concentration only. The results confirm the dissolution of sulfate salts and evaporate minerals, in addition to high agricultural lands and farm activities, besides the wastes from chemical construction industries.
The study investigates the water quality of the Orontes River, which is considered one of the important water recourses in Syria, as it is used for drinking, irrigation, swimming and industrial needs. A database of 660 measurements for 13 parameters concentrations used, were taken from 11 monitoring points distributed along the Orontes River for a period of five years from 2015-2019, and to study the correlation between parameters and their impact on water quality, statistical analysis was applied using (SPSS) program. Cluster analysis was applied in order to classify the pollution areas along the river, and two groups were given: (low pollution - high pollution), where the areas were classified according to the sources of pollution to w
... Show MoreElectrical resistivity methods are one of the powerful methods for the detection and evaluation of shallower geophysical properties. This method was carried out at Hit area, western Iraq, in two stages; the first stage involved the use of 1Dimensional Vertical Electrical Sounding (VES) technique in three stations using Schlumberger array with maximum current electrodes of 50m. The second stage included the employment of two dimension (2D) resistivity imaging technique using dipole-dipole array with a-spacing of 4m and n-factor of 6 in two stations. The 1D survey showed good results in delineating contaminated and clear zones that have high resistivity contrast. Near the main contaminated spring, the 2D resi
... Show MoreWater is necessary for sustainable development and healthy society. Groundwater, often, is not sufficient and protected for direct human consumption. Due to increase in the density of population the requirement of water is increasing. In this work, the assessment of groundwater quality was conducted in the south-west part of Basrah province. Spatial variations in the quality of groundwater in the study area have been analyzed utilizing GIS technique. The geochemical parameters of groundwater samples including pH, EC, TDS, Ca, Mg, Na, Cl, HCO3, SO4, and NO3 were assessed in this study. Information maps of the study area have been actually prepared to make use of the GIS spatial
... Show MoreThe resistivity survey was carried out by using vertical electrical sounding (VES) and 2D imaging techniques in the northern Badra area, Eastern Iraq. Eleven VES points distributed on two parallel profiles and six 2D imaging stations were applied using long survey lines.
In general, two types of aquifers are recognized in the study area. The first is the Quaternary aquifer, which appears in all geological sections and inverse model of 2D imaging stations (2DS).This aquifer can be divided into upper and lower aquifers as shown in (2DS1), (2DS3), and (2DS4). Generally, the thickness of this aquifer ranges between (30-200 m) which occurs at a depth of (10-30m) according to geological sections, while its thickness ranges between (35-180m)
The groundwater evaluation has been carried out in Khanaqin area in Diyala governorate to the east of Iraq. The analyzed hydrochemical parameters such as pH, electrical conductivity, total dissolved solids as well as cations and anions are used to describe groundwater quality and its suitability for different purposes. The study area covers (1920) km2. According to hydrogeological investigation (43) water points were inventoried and water levels in wells were measured. (34) Wells were sampled during 2013-2014 during water surplus and water deficit periods. The studied area is divided groundwater aquifers into two main units, the unconfined and confined aquifers. The values of pH, electrical conductivity (EC) and total dissolve
... Show MoreSeismic instantaneous phase attribute was applied for conventional seismic interpretation (structural interpretation) on 3D seismic cube of 1914.72km² of Samawa-Diwan area, located in the south part of Iraq within Muthna governorate. Instantaneous phase section is very important to detect structural and stratigraphic features. Six reflectors represent Upper Jurassic and Cretaceous formations were defined from synthetic seismogram of wells in study area, then picked over seismic cube. Fault boundaries maps for each horizon were drawn depending on horizon contacts then fault planes were constructed. Finally, a 3D structural model was constructed in time domain, then converted to depth domain by using 3D average velocity model. Structurall
... Show MoreThe objective of this research is to select the most suitable drilling location of new groundwater exploration wells, with a decision-making tool from Geographic Information System (GIS). The optimum location will be evaluated base on the hydro-geoelectrical parameter derived from Vertical Electrical Sound (VES) including Longitudinal Conductance, the thickness of the aquifer, the apparent resistivity and Transmissivity. From the Geo-electrical method (VES) the finds shows that the aquifers in the study area have Apparent Resistivity ranging from 0.32 to 40.24 Ωm, Thickness between 0.21 m to 15.06 m, Longitudinal Conductance ranging from 0.006 to 10.246Ω-1 and Transmissivity ranging from 0.14 to
... Show MoreThis paper aims to evaluate large-scale water treatment plants’ performance and demonstrate that it can produce high-level effluent water. Raw water and treated water parameters of a large monitoring databank from 2016 to 2019, from eight water treatment plants located at different parts in Baghdad city, were analyzed using nonparametric and multivariate statistical tools such as principal component analysis (PCA) and hierarchical cluster analysis (HCA). The plants are Al-Karkh, Sharq-Dijlah, Al-Wathba, Al-Qadisiya Al-Karama, Al-Dora, Al-Rasheed, Al-Wehda. PCA extracted six factors as the most significant water quality parameters that can be used to evaluate the variation in drinkin
Groundwater suitability for consumption in the Yaychi area is determined by analyzing groundwater samples of 21 wells distributed in the area, for dry period which begin from May to October 2016 and wet period begin from October 2016 to May 2017. Results indicated that the temperature (T °C) have normal values and the
water of low alkaline and excessively mineralized, while most of these samples, for both periods, are slightly – brackish water. The mean ion concentrations for two periods indicates that all major and secondary ions are higher than water quality standards for drinking purposes according to World Health Organization (WQI) and
Iraqi Standard (IQS) except for K and Cl ions. The water in