This paper aims to deal with the understanding of the properties of the molecular gas hydrogen in the extragalactic spirals sample. It is critical to make observations of CO (J = 1-0) line emission for spiral galaxies, particularly those with an energetic nucleus. In the sample of spiral galaxies compiled, a carbon monoxide CO (1-0) emission line can be observed. This sample of galaxies' gas kinematics and star-forming should be analyzed statistically utilizing appropriate atomic gas HI, molecular gas H2, infrared (1μm-1000μm), visual (at λblue-optical=4400A0), and radio spectrum (at νradio=1.4 GHz and 5GHz) databases. STATISTICA is software that allows us to perform this statistical analysis. The presence of a high scale of star formation activity in these galaxies is dependent linearly on the correlations between galactic luminosities. Our findings show that thermal radio luminosity and LFIR are closely related to CO line luminosity. Further, LCO and MH2 have a steep linear relationship, where the slope of the regression log LCO - LogMH2 equals 1. The LCO-SFR and LFIR-SFR relationship slopes are nearly linear (slope ~1), with a strong partial correlation RCO-SFR of 0.73 between LCO-SFR and a significant correlation RFIR-SFR of 0.5 between LFIR-SFR, according to the statistical analysis. The correlation between the rate of star formation (SFR) and hydrogen gas in spirals is significant in several fields of astrophysics. Hence, it is asserted that the important point of the current study is that there is a significant link between SFR and the actual amount of cold hydrogen gas (Mgas) for the simple reason that in our spiral analysis, the mean atomic cold gas amount quantity is almost 6 times greater than the molecular gaseous amount.
The current research reports the preparation and fabrication of the silver paste conductor which is employed as a soldering material for electro – optical components ohmic interconnections. The prepared paste possesses electrical characteristics identical to the ohmic connectors as its observable from resistance – temperature variation. Moreover, the I – V characteristics obeys Ohm’s law and this dependency was further confirmed by the nearly constant capacitance measurements with voltage and frequency. A noticeable improvement in electrical conductivity, compared to the pure silver paste sample, was noted for samples prepared by mixing predetermined weight ratios of brass and copper. Furthermore, stability of electrical resistan
... Show MoreThe present study aims to assess the water quality and the hydrochemical characteristics and seasonal variation of surface water on the aspect of trace elements in Al-Tarmiyah District, Baghdad, Iraq. Ten water samples were collected, four from surface water and six from groundwater on October 2017, and on April 2018. All samples were analyzed for physiochemical parameters such as water temperature, pH, EC, TDS,TH,TSS, major ions (Ca2+, Mg2+, Na+, K+, SO42-, Cl-, and HCO3-), and nutrients (NO3-, and PO43-). In addition, samples were analyzed for trace elements that include Fe, Al, Pb, Zn, Mn, Cr,
... Show MoreDysregulation of matrix metalloproteinases-9 (MMP-9) and tissue inhibitors of
matrix metalloproteinases-1 (TIMP-1) may contribute to the development of
cardiovascular diseases in type 2 diabetes mellitus (T2DM) patients. The aim of this
study was to determine the effects of chronic hyperglycemia on serum
concentrations of MMP-9 and TIMP-1of T2DM patients without dyslipidemia (one
of atherosclerosis risk factors) and with duration less than 5 years in comparison
with T2DM patients with dyslipidemia and with duration more than 10 years and
controls. Also to investigate if serum levels of MMP-9 and TIMP-1 could be
potential markers for early detection of the development of cardiovascular
complications in T2DM pati
In this work, the effects of solvent properties on the characteristics of absorption and fluorescence for two laser dyes was studied. Dyes used in this work include Coumarin 5400 and DCM, while the solvents include ethanol, methanol, acetone, propanol and chloroform. Coumarin 5400 dye shows sharp fluorescence peaks in the green band of visible region while the DCM dye shows relatively wide band within 590-630 nm. Therefore, the selection of any dye for random gain medium applications should be performed after determining the most appropriate solvent as the optimum fluorescence characteristics are obtained.