This research aims to investigate parameters for magnesium (Mg) carbon (C), and carbon/magnesium plasma produced by the exploding electrical wire (EEW) technique. In this work, C and Mg nanoparticles were synthesized. The plasma spectra with three different current values (50, 75 and 100A) were recorded using optical emission spectroscopy (OES). The plasma electron temperature (Te), electron density (ne), plasma frequency (fp), Debye length (ℷD), and Debye number (ND) provided by arc discharge plasma were calculated. Boltzmann plots were used to calculate the electron temperature (Te); electron density (ne) was calculated by Stark broadening . The results showed that the electron temperature and electron density increased with the increase of current. For carbon plasma, Te increased from (1.243 to 1.533) eV, and ne increased from (8.762 to 9.857) cm-3. Te for magnesium plasma increased from (0.508 to 0.724)eV and ne increased from(6.700 to 10.420) cm-3. When the magnesium strip was exploded in carbon suspension, Te increased from (0.744 to 0.851) eV, and electron density was raised from (5.738 to 9.304)cm-3.
Non thermal argon plasma needle at atmospheric pressure was constructed. The experimental set up was based on simple and low cost electric components that generate electrical field sufficiently high at the electrodes to ionize various gases which flow at atmospheric pressure. A high AC power supply was used with 9.6kV peak to peak and 33kHz frequency. The plasma was generated using two electrodes. The voltage and current discharge waveform were measured. The temperature of Ar gas plasma jet at different gas flow rate and distances from the plasma electrode was also recorded. It was found that the temperature increased with increasing frequency to reach the maximum value at 15 kHz, and that the current leading the voltage, which demonstra
... Show MoreIn this work, plasma parameters such as (electron temperature (Te), electron density (ne), plasma frequency (fp) and Debye length (λD)) were studied using spectral analysis techniques. The spectrum of the plasma was recorded with different energy values, SnO2 and ZnO anesthetized at a different ratio (X = 0.2, 0.4 and 0.6) were recorded. Spectral study of this mixing in the air. The results showed electron density and electron temperature increase in zinc oxide: tin oxide alloy targets. It was located that The intensity of the lines increases in different laser peak powers when the laser peak power increases and then decreases when the force continues to increase.
In this work, electron number density calculated using Matlab program code with the writing algorithm of the program. Electron density was calculated using Anisimov model in a vacuum environment. The effect of spatial coordinates on the electron density was investigated in this study. It was found that the Z axis distance direction affects the electron number density (ne). There are many processes such as excitation; ionization and recombination within the plasma that possible affect the density of electrons. The results show that as Z axis distance increases electron number density decreases because of the recombination of electrons and ions at large distances from the target and the loss of thermal energy of the electrons in high distance
... Show MoreIn this work, diamond-like carbon (DLC) thin films were prepared from Cyclohexane. Thin films were deposited on quartz substrate by atmospheric pressure Argon plasma jet system. The plasma jet system was applying high voltage sinusoidal waves of frequency 28 kHz and potential difference of 7.5kV peak to peak across the electrodes. The effect of annealing at 400, 500 and 600 °C under vacuum for two hours on optical properties and structural properties of the DLC thin films were investigated. This effect was clarified by X-ray diffraction (XRD), FTIR, UV-Visible absorption, Scanning Electron Microscopy (SEM) and Raman Spectroscopy. The X-ray diffraction patterns for the annealing DLC thin films show two broad peaks at 2θ, 26.62° and 51.58
... Show MoreIn this work, the Al-Mg alloys plasma plume that produced under vacuum (10-1 torr) by Nd:Yag Laser was studied. the plasma spectra were analyzed by comparing the atomic lines of Al and Mg lines with standard lines. The effect of laser energies on spectral lines produced by laser ablation were investigated using optical
spectroscopy .several plasma characteristics like electron temperature, electron density, Debye’s length, plasma frequency and number of particles in the ‘‘Debye’s Sphere’’ were calculated in vacuum .The results show the electron temperature and electron density increase in magnesium, aluminum and magnesium :aluminum alloy
targets . It was found that the lines intensities at
In this research, the effect of electrode material on the parameters of the produced DBD plasma was investigated. First, a non-thermal plasma was created by applying a 15 kV AC voltage between two electrodes and using a glass plate as a dielectric barrier in the design Dielectric Barrier Discharge (DBD) plasma system. The obtained plasma spectrum was analyzed using optical emission spectroscopy to calculate plasma parameters by the Boltzmann plot method. Electrodes made of copper, aluminium, and stainless steel were employed in this research. Electron temperature ( ) for copper, aluminium, and stainless steel was found to be (1.398 eV), (1.093 eV) and (1.009 eV), respectively.
The use of multifunction additives in the lubricant sector has attracted great interest due to their ability to simultaneously improve and add multiple functions. This work describes the preparation and evaluation of over-based magnesium stearate detergent as a multifunction additive by the reaction of stearic acid with carbon dioxide gas in the presence of magnesium oxide nanoparticles and ammonia. The prepared over-based magnesium stearate was evaluated as a multifunction additive through blending it in various concentrations of 1-5 wt/wt% with sixty stock lubricating oils. The American Society for Testing and Materials (ASTM) and the Institute of Petroleum (IP) were used to determine the total base number (TBN), viscosity ind
... Show MoreNon thermal argon plasma needle at atmospheric pressure was generated. The experimental set up is based on very simple and low cost electric components that generate electrical field sufficiently high at the electrodes to ionize various gases, which flow at atmospheric pressure. The high d.c power supply is 7.5kV peak to peak, the frequency of the electrical field is 28kHz, and the plasma power less than 15W. The plasma is generated using only one electrode. In the present work the voltage and current discharge waveform are measured. Also the temperature of the working Ar gas at different gas flow and distances from the plasma electrode tip was recorded
This research studies the effect regarding two plasma types, plasma jet and plasma-activated water (PAW), on tooth root canal bacteria Enterococcus faecalis. The plasma jet works with argon gas, and it is generated by a power supply that operates at alternating high voltages in the form of a sinusoidal wave with peak-to-peak value of about 12 kV at a frequency of 30 KHz and its power is about 200 watts. This plasma was utilized directly to treat the tooth canal and indirectly by activating the water that was used later for treating the Enterococcus faecalis bacteria that are present in the tooth root. Pure distilled water was treated by plasma jet for one hour at flow rate 1 . Plasma water activated by plasma contains
... Show MoreBackground: Leukemias and lymphomas are malignant disorders that occur in the blood forming organs and lymphoid tissue respectively. They are classified to types and several subtypes such as acute or chronic, lymphocytic or myelocytic and T-cell or B-cell lymphocytic for leukemias and histologically into Hodgkin’s and Non-Hodgkin’s for lymphomas. Literatures do not contain many research work on magnesium in patients with these disorders, although this mineral is essential for many metabolic, enzymic, regulatory and immune reactions in the human body. Therefore, the present study was aimed to evaluate the level of magnesium in the sera of patients with different types of leukemia and lymphoma.
Patients