Preferred Language
Articles
/
ijs-7727
Effect of Plasma-Activated Water and Direct Plasma on Enterococcus faecalis Bacteria for Disinfection of Tooth Root Canal

     This research studies the effect regarding two plasma types, plasma jet and plasma-activated water (PAW), on tooth root canal bacteria Enterococcus faecalis. The plasma jet works with argon gas, and it is generated by a power supply that operates at alternating high voltages in the form of a sinusoidal wave with peak-to-peak value of about 12 kV at a frequency of 30 KHz and its power is about 200 watts. This plasma was utilized directly to treat the tooth canal and indirectly by activating the water that was used later for treating the Enterococcus faecalis bacteria that are present in the tooth root. Pure distilled water was treated by plasma jet for one hour at flow rate 1 . Plasma water activated by plasma contains NO2, NO3, and H2O2 with a concentration (10,100,200) ppm, respectively. It was noted, as a result of direct exposure with the two values of gas flow rate and for different exposure times, an ideal killing rate (from 298 x 108 to zero)CFU/ml was obtained when the exposure time changed from (5-30) minutes with a constant gas flow rate of 2.5 ; while in the case of changing the gas flow rate from (0.5-2.5)  and fixing time to 5 min, the killing rate decreased from (298 ×108 to 30×108) CFU/ml. In the case of (PAW) when the time changed (5-25) min, an ideal killing rate was obtained (298 x 108 to zero) CFU/ml; adopted one factor, where the results indicated that plasma-activated water is good in disinfecting the root canal of the tooth and inactivating bacteria.

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Dec 30 2023
Journal Name
Iraqi Journal Of Science
Comparison Study of Plasma-Activated Water and Plasma Jet Effects on Escherichia coli Bacteria for the Disinfection of Tooth Root Canal

This study compares the effects of plasma jet and plasma-activated water on teeth root canals contaminated with Escherichia coli bacteria. A plasma jet system was developed for biological purposes that operate at atmospheric pressure. The plasma jet works with argon gas and is generated by a power supply, which supplies a sinusoidal alternating voltage of 12 kV of 20 kHz frequency. The system was optically diagnosed, as it was found that the peaks of the nitrogen spectrum were obtained at the wavelength (300- 450) nm with the appearance of hydroxide peaks at 380 nm. Extracted teeth with one root canal were used, which were contaminated with bacteria and divided into two groups to be treated with a plasma jet and plasma-activated

... Show More
Scopus Crossref
View Publication Preview PDF
Publication Date
Sun Apr 09 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Identification of Enterococcus faecalis Isolated from Infected Human Tooth Root Canals Human by Using Polymerase Chain Reaction

     One hundred samples of root canal bacteria were isolated  from patients teeth with primary and secondary infected root canal from all the ages . Biochemical and microscopial tests were done for identification of these isolates. Twenty four isolates were confirmed as       E. faecalis species by using these tests. Genetic diagnosis for the all isolates was also done by using polymerase chain reaction ( PCR ). Thirty two isolates were confirmed to  belong to E. faecalis species by using this test.

View Publication Preview PDF
Publication Date
Sun Dec 05 2021
Journal Name
Iraqi Journal Of Science
The Effect of the Non-Thermal Plasma Needle on Pseudomonas Aeruginosa Bacteria

The development in the field of medical physics has led to the use of devices that
are manufactured under normal conditions to make tremendous progress in the
world of development in medical treatment by using these devices with modern
techniques by reducing the use of antibiotics and relying on these tools and devices
that link between physics and modern therapeutic medicine. In this research, a nonthermal
plasma system for argon gas operated at normal atmospheric pressure was
designed, this system was applied on Pseudomonas Aeruginosa bacteria isolated
from burn patients from Yarmouk Teaching Hospital. These bacteria were exposed
to this system, the results showed that these bacteria were killed at time (5 min)

... Show More
View Publication Preview PDF
Publication Date
Sun Jul 02 2023
Journal Name
Iraqi Journal Of Science
Isolation and Identification of Vancomycin-Resistant Enterococcus Faecalis

One hundred thirty - five clinical specimens of urine, blood, teeth root canal and burns were obtained from patients in hospitals of Baghdad. The specimens were cultured on Pfizer Selective Enterococcus agar to purify Enterococci isolates. 20 E. faecalis isolates were identified biochemically by growing in 10Cº, 45Cº, 6.5% NaCl, at pH 9.6 and confirmed by VITEK. Determination of Vancomycin-Resistant E. faecalis isolates were done by the minimum inhibitory concentrations [MICs] using agar dilution method. Seventeen E. faecalis isolates were determined as Vancomycin-Resistant and Intermediate Resistant.

View Publication Preview PDF
Publication Date
Sun Oct 22 2023
Journal Name
Iraqi Journal Of Science
Isolation and Identification of Vancomycin-Resistant Enterococcus Faecalis

One hundred thirty - five clinical specimens of urine, blood, teeth root canal and burns were obtained from patients in hospitals of Baghdad. The specimens were cultured on Pfizer Selective Enterococcus agar to purify Enterococci isolates. 20 E. faecalis isolates were identified biochemically by growing in 10Cº, 45Cº, 6.5% NaCl, at pH 9.6 and confirmed by VITEK. Determination of Vancomycin-Resistant E. faecalis isolates were done by the minimum inhibitory concentrations [MICs] using agar dilution method. Seventeen E. faecalis isolates were determined as Vancomycin-Resistant and Intermediate Resistant.

View Publication Preview PDF
Publication Date
Tue Jan 08 2019
Journal Name
Iraqi Journal Of Physics
Effect of plasma jet on the water and hydrogen peroxide that used for assisted teeth bleaching

In this work the interaction of plasma jet with water and hydrogen peroxide liquids used for assisted teeth bleaching by plasma jet had been study. A homemade plasma jet system was used. The plasma jet supply by 15 W electrical power generated by high voltage power supply of 9.6 kV peak to peak and frequency of 33 kHz .this power supply generate high electric field on electrodes that would be enough to ionize the argon gas. Some important agents were study such as the effect of the Ar gas flow rates on the length of the plasma jet, the influence of plasma jet on some properties of water and two hydrogen peroxide concentrations 25 % and 30 % like pH, conductivity and liquid temperature for different exposure time. The liquids temperature

... Show More
Crossref (1)
Crossref
View Publication Preview PDF
Publication Date
Sun Jan 01 2023
Journal Name
Open Veterinary Journal
Plasma-activated water application for detoxification of aflatoxin B1, ochratoxin A, and fumonisin B1 in poultry feeds

Background: Plasma-activated water (PAW) is considered one of the emerging strategies that has been highlighted recently in the food industry for microbial decontamination and mycotoxin detoxification, due to its unique provisional characteristics. Aim: The effectiveness of PAW for aflatoxin B1 (AFB1), ochratoxin A (OTA), and fumonisin B1 (FB1) detoxification in naturally contaminated poultry feeds with its impacts on the feed quality were inspected. Methods: PAW-30 and PAW-60 were utilized for feed treatment for six time durations (5, 10, 15, 20, 40 and 60 min) each. The alterations in the physicochemical properties of PAW after different time durations of plasma inducement and treatment with and without feed samples were monit

... Show More
Scopus (1)
Crossref (1)
Scopus Clarivate Crossref
View Publication
Publication Date
Sun Jul 01 2012
Journal Name
Journal Of The Faculty Of Medicine Baghdad
Antagonstic Effect of Lactobacillus Fermentum Supernatant AgainstEnterococcus Faeciumand Enterococcus Faecalis In Vitro

Background:Lactobacillus fermentum selected as an alternative treatment to prevent or treat urogenital infection based on their probiotics properties and production of bacteriocins.
Objective: The present work was done to study the inhibition activity of L. fermentum cell free supernatant against urogenital pathogens Enterococcus faecium and Enterococcus faecalisinvitro.
Materials and methods: L.fermentum isolates have been collected from vaginal swabs . A supernatant of these isolates has been prepared and its antibacterial activity against 3 isolates of E.faecium and 3 isolates of E.faecalis has been studied.
Results: Different concentrations have been prepared and the most effective one was 1000μg/ml and the most affected is

... Show More
Crossref (5)
Crossref
View Publication Preview PDF
Publication Date
Tue Oct 02 2018
Journal Name
Iraqi Journal Of Physics
Effect of gas flow rate on plasma temperature and electron density of atmospheric argon plasma jet

In this study, method for experimentally determining the electron density (ne) and the electron temperature (Te) in the atmospheric Argon plasma jet is used; it is based on optical emission spectroscopy (OES). Boltzmann plot method used to calculate these parameters measured for different values of gas flow rate. The results show that the electron temperature decreasing with the increase of gas flow rate also indicates an increasing in the electron density of plasma jet with increasing of gas flow rate.

Crossref (3)
Crossref
View Publication Preview PDF
Publication Date
Mon Jan 01 2024
Journal Name
Brazilian Dental Science
Scopus