Preferred Language
Articles
/
ijs-4154
Evaluation of Chitosan-Alginate Nanoparticle as A Stable Antibacterial Formula in Biological Fluids
...Show More Authors

      This research mainly focuses on the preparation of chitosan-alginate Nanoparticle by ionotropic gelation method using calcium chloride and sodium alginate to form nanocomposites of CH-ALg, examine their antibacterial activity against multidrug resistance (MDR) bacteria, and evaluate the stability of chitosan-alginate formula in different biological fluids, including simulated gastric fluid (SGF) and intestinal fluid (SIF). The average diameter of particles size prepared was measured by an Atomic force microscope (AFM) and it was 61.91 nm. Otherwise, the nature of functional groups present in CH-ALg nanoparticle was investigated by Fourier transforms infrared (FTIR) analysis. The stability of synthesized CH-ALg nanoparticle was measured by Zeta potential measurement and show high stability with a 79 mV ratio. The SEM picture shows that particles are shown to be in the form of bundles and the size of nanoparticles was in the range of (14-84nm). The antibacterial activity of CH-ALg was tested against (MDR) Gram-positive bacteria (staphylococcus aureus) and Gram-negative bacteria (Salmonella typhi, Pseudomonas aeruginosa, and Enterobacter cloacae). The results exhibited a significant impact of antibacterial action against isolates of MDR. CH-ALg nanoparticles were loaded with antibiotic doxycycline in order to strengthen the antibacterial action and drug delivery effectiveness. The synergistic effects of prepared CH-ALg loaded with DOX antibiotic at several concentrations toward MDR bacteria were also examined. The results indicate that DOX-loaded nanoparticles have a significant improvement for antibacterial activity against Gram-negative and Gram-positive compared to doxycycline alone. The formula of chitosan- alginate was stabile in various biological fluids including simulated gastric fluid (SGF) and simulated intestinal fluid (SiF)

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Feb 01 2024
Journal Name
Heliyon
Removal of amoxicillin from contaminated water using modified bentonite as a reactive material
...Show More Authors

This study concerns the removal of a trihydrate antibiotic (Amoxicillin) from synthetically contaminated water by adsorption on modified bentonite. The bentonite was modified using hexadecyl trimethyl ammonium bromide (HTAB), which turned it from a hydrophilic to a hydrophobic material. The effects of different parameters were studied in batch experiments. These parameters were contact time, solution pH, agitation speed, initial concentration (C0) of the contaminant, and adsorbent dosage. Maximum removal of amoxicillin (93 %) was achieved at contact time = 240 min, pH = 10, agitation speed = 200 rpm, initial concentration = 30 ppm, and adsorbent dosage = 3 g bentonite per 1L of pollutant solution. The characterization of the adsorbent, modi

... Show More
View Publication
Scopus (8)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Mon Jan 01 2024
Journal Name
Journal Of Engineering
Evaluating the Moisture Susceptibility of Asphalt Mixtures Containing Aluminum Dross as a Filler
...Show More Authors

One of the most essential components of asphalt pavements is the filler. It serves two purposes. First, this fine-grained material (diameter less than 0.075 mm) improves the cohesiveness of aggregate with bitumen. Second, produce a dense mixture by filling the voids between the particles. Aluminum dross (AD), which is a by-product of aluminum re-melting, is formed all over the world. This material causes damage to humans and the environment; stockpiling AD in landfills is not the best solution. This research studies the possibility of replacing part of the conventional filler with aluminum dross. Three percent of dross was used, 10, 20, and 30% by filler weight. The MarshallMix design method was adopted to obtain the op

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Jun 19 2023
Journal Name
Journal Of Polymer Research
Design, and synthesis of a plasticizer- Schiff’s bases complexes as additive for polystyrene
...Show More Authors

This work involved the successful synthesis of three new Schiff base complexes, including Ni(II), Mn(II), and Cu(II) complexes. The Schiff base ligand was created by reacting the malonyldihydrazide molecule with naphthaldehyde, and the final step involved reacting the ligand with the corresponding metallic chloride yielding pure target complexes. FTIR, 1 H NMR, 13 C NMR, mass, and UV/Vis spectroscopies were used to comprehensively characterize the produced complexes. These substances have been employed in this study to photo-stabilize polystyrene (PS) and lessen the photo-degradation of its polymeric chains. Several methods, including FTIR, weight loss, viscosity average molecular weight, light and atomic force microscopy, and energy disper

... Show More
Scopus (3)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Mon Sep 04 2017
Journal Name
International Journal Of Environmental Science And Technology
A review of permeable reactive barrier as passive sustainable technology for groundwater remediation
...Show More Authors

Scopus (132)
Crossref (118)
Scopus Clarivate Crossref
Publication Date
Sun Dec 13 2020
Journal Name
Clinical And Experimental Dental Research
The efficacy of polyether‐ether‐ketone wire as a retainer following orthodontic treatment
...Show More Authors
Abstract<sec><title>Objectives

To investigate the efficacy of polyether‐ether‐ketone (PEEK) wire as a fixed orthodontic retainer, by comparing its performance to other retainer wires and optimizing its adhesion to composite bonding materials.

Materials and methods

Retainer wires of 15 mm segments were used, PEEK wires were prepared in cylindrical form with 0.8 mm diameter, and had two surface treatments namely air‐abrasion and conditioning with adhesive system. Three different metallic retainer wires were used for comparison and three tests were performed; two tests measured debonding force and associated wire deflec

... Show More
View Publication
Scopus (16)
Crossref (11)
Scopus Clarivate Crossref
Publication Date
Tue Apr 25 2023
Journal Name
Journal Of Periodontal Research
Salivary E‐cadherin as a biomarker for diagnosis and predicting grade of periodontitis
...Show More Authors
Abstract<sec><title>Objectives

To determine the abilities of salivary E‐cadherin to differentiate between periodontal health and periodontitis and to discriminate grades of periodontitis.

Background

E‐cadherin is the main protein responsible for maintaining the integrity of epithelial‐barrier function. Disintegration of this protein is one of the events associated with the destructive forms of periodontal disease leading to increase concentration of E‐cadherin in the oral biofluids.

Materials and Methods

A total of 63 patients with periodontitis (case) and 35

... Show More
View Publication
Scopus (8)
Crossref (8)
Scopus Clarivate Crossref
Publication Date
Fri Jul 01 2022
Journal Name
Iraqi Journal Of Science
Antibacterial and Antioxidant Activites of Secondary Metabolites of Endophytic Fungus Stemphylium radicinum (Meier, Drechs and Eddy)
...Show More Authors

Abstract
Endophytic fungi are gaining interest as sources of novel bioactive metabolites.
The study was carried out to screen and isolate endophytic fungus.An endophytic
fungus isolated from root of calyptous plant .The fungus was identified as
Stemphylium radicinum (Meier, Drechs and Eddy)based on morphological
characterization. Fungal secondary metabolites was carried out by ethyl acetate
solvent.The antibacterial activity was tested against five bacterial isolates.
Esherichia coli, Staphylococcus aureus, Proteus vulgaris, Klebsiella pneumonia and
Streptococcus pyogenes by using a disc diffusion technique. The inhibition zones
exhibited by Fungal secondary metabolites were ranged between 22.5-35.5 mm.
Mini

... Show More
View Publication Preview PDF
Publication Date
Tue May 30 2023
Journal Name
Iraqi Journal Of Science
Smartphones as Smart Tools for Science and Engineering Laboratory: A Review
...Show More Authors

     This article reviews a decade of research in transforming smartphones into smart measurement tools for science and engineering laboratories. High-precision sensors have been effectively utilized with specific mobile applications to measure physical parameters. Linear, rotational, and vibrational motions can be tracked and studied using built-in accelerometers, magnetometers, gyroscopes, proximity sensors, or ambient light sensors, depending on each experiment design. Water and sound waves were respectively captured for analysis by smartphone cameras and microphones. Various optics experiments were successfully demonstrated by replacing traditional lux meters with built-in ambient light sensors. These smartphone-based measurement

... Show More
View Publication Preview PDF
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Sun Mar 15 2020
Journal Name
Journal Of The College Of Education For Women
Data-Driven Approach for Teaching Arabic as a Foreign Language: Eygpt
...Show More Authors

Corpus linguistics is a methodology in studying language through corpus-based research. It differs from a traditional approach in studying a language (prescriptive approach) in its insistence on the systematic study of authentic examples of language in use (descriptive approach).A “corpus” is a large body of machine-readable structurally collected naturally occurring linguistic data, either written texts or a transcription of recorded speech, which can be used as a starting-point of linguistic description or as a means of verifying hypotheses about a language.  In the past decade, interest has grown tremendously in the use of language corpora for language education. The ways in which corpora have been employed in language pedago

... Show More
View Publication Preview PDF
Publication Date
Fri Dec 30 2011
Journal Name
Al-kindy College Medical Journal
Postprandial Hyperglycemia as a Significant Risk Factor for Coronary Heart Disease
...Show More Authors

Background: The highest concentrations of
blood glucose during the day are usually found
postprandialy. Postprandial hyperglycemia (PPH)
is likely to promote or aggravate fasting
hyperglycemia. Evidence in recent years suggests
that PPH may play an important role in functional
& structural disturbances in different body organs
particularly the cardiovascular system.
Objective: To evaluate the effect of (PPH) as a
risk factor for coronary Heart disease in Type 2
diabetic patients.
Methods: Sixty-three type2 diabetic patients
were included in this study. All have controlled
fasting blood glucose, with HbA1c correlation.
They were all followed for five months period
(from May to October 2008)

... Show More
View Publication Preview PDF