This research mainly focuses on the preparation of chitosan-alginate Nanoparticle by ionotropic gelation method using calcium chloride and sodium alginate to form nanocomposites of CH-ALg, examine their antibacterial activity against multidrug resistance (MDR) bacteria, and evaluate the stability of chitosan-alginate formula in different biological fluids, including simulated gastric fluid (SGF) and intestinal fluid (SIF). The average diameter of particles size prepared was measured by an Atomic force microscope (AFM) and it was 61.91 nm. Otherwise, the nature of functional groups present in CH-ALg nanoparticle was investigated by Fourier transforms infrared (FTIR) analysis. The stability of synthesized CH-ALg nanoparticle was measured by Zeta potential measurement and show high stability with a 79 mV ratio. The SEM picture shows that particles are shown to be in the form of bundles and the size of nanoparticles was in the range of (14-84nm). The antibacterial activity of CH-ALg was tested against (MDR) Gram-positive bacteria (staphylococcus aureus) and Gram-negative bacteria (Salmonella typhi, Pseudomonas aeruginosa, and Enterobacter cloacae). The results exhibited a significant impact of antibacterial action against isolates of MDR. CH-ALg nanoparticles were loaded with antibiotic doxycycline in order to strengthen the antibacterial action and drug delivery effectiveness. The synergistic effects of prepared CH-ALg loaded with DOX antibiotic at several concentrations toward MDR bacteria were also examined. The results indicate that DOX-loaded nanoparticles have a significant improvement for antibacterial activity against Gram-negative and Gram-positive compared to doxycycline alone. The formula of chitosan- alginate was stabile in various biological fluids including simulated gastric fluid (SGF) and simulated intestinal fluid (SiF)
A metal mandrel was designed for manufacturing the cathodes of high power electron tube ( Tetrode ) used in broadcasting transmitting tubes type TH558 and CQS200.The cathodes were manufactured in the present work from thoriated tungsten wires ( 2? ThO2- W) with different diameters .These cathodes were carbonized in sequences of processes to determine the carbonization parameters (temperature, pressure, time, current and voltage).Then the carbonized cathodes dimension were accurately measured to determine the deviation due to the high temperature distortion effect at about 1800°C .the distorted cathodes due to the carbonization process was treated when it was subjected inside the vacuum chamber and heat treated again .The carbonized cat
... Show MoreAbstract
Backgrounds: Jaundice occurs in most newborn due to increased bilirubin concentration. Jaundice is observed during the first week after birth in approximately 60% of term neonates. A high level of bilirubin is neurotoxic and may cause neonatal kernicterus, auditory neuropathy or death.
Objectives: to compare the Rh group compatibility, serum bilirubin (total and direct), serum albumin and several liver enzymes between physiological and pathological neonatal jaundice
Materials and Methods: A cross sectional study for one hundred neonates with jaundice divided into group 1: 50 newborns with physiological jaundice, Group 2: 50 newborns with
... Show MoreThe corrosion of carbon steel in single phase (water with 0.1N NaCl ) and two immiscible phases (kerosene-water) using turbulently agitated system is investigated. The experiments are carried out for Reynolds number (Re) range of 38000 to 95000 corresponding to rotational velocities from 600 to 1400 rpm using circular disk turbine agitator at 40 0C. In two-phase system test runs are carried out in aqueous phase (water) concentrations of 1 % vol., 5 % vol., 8% vol., and 16% vol. mixed with kerosene at various Re. The effect of Reynolds number (Re), percent of dispersed phase, dispersed drops diameter, and number of drops per unit volume on the corrosion rate is investigated and discussed. Test runs are carried out using two types of
... Show MoreTwo series of Schiff Bases and 2,3-disubstituted-1,3-thiazolidin-4-one derivatives were synthesized . Reaction of 2-mercaptobenzothiazole with α-chloro acetic acid gave compound[I]. Esterification of carboxylic moity of compound [I] , using absolute methanol in the presence of conc . H2SO4 yielded acorresebonding ester [II] , wich was condensation with hydrazine hydrate to give acid hydrazide [III] . The new Schiff bases [V]n were synthesized by reaction of acid hydrizide with dialdehyde [IV]n in the presence of glacial acetic acid . The thiazolidinone derivatives [VI]n have been obtained from the azomethines through the addition of thioglycolic acid . Their chemical structures have been confirmed by mel
... Show MoreFor extraction chloro anion complexes of Cd2+ and Hg2+ used many organic agents as extractant according to liquid ion exchange method such as α-Naphthyl amine (α-NA), 4-Amino benzoic acid (4-ABA), 2-[(4-Carboxy methyl phenyl) azo]-4,5-diphenyl imidazole (4CMePADPI) and Cryptand (C222). This study includes definition hydrochloric acid concentration in aqueous phase and shaking with organic phase necessary for extraction as well as shaking time, organic solvent effect, interferences and alkaline salt effect. Thermodynamic showed the ion exchange reaction was exothermic for α-NA, C222 and endothermic for 4-ABA, 4-CMePADPI for extraction CdCl4=, but for extraction HgCl4= was exothermic with 4-ABA, 4CMePADPI and C222 but
... Show MoreCharge transfer complex formation method has been applied for the spectrophotometric determination of cimetidine, in bulk sample and dosage form. The method was accurate, simple, rapid, inexpensive and sensitive depending on the formed charge- transfer complex between cited drug and, 2,3-Dichloro-5,6-dicyano-p- benzoquinone (DDQ) as a chromogenic reagent. The formed complex shows absorbance maxima at 587 nm against reagent blank. The calibration graph is linear in the ranges of (5.0 - 50.0) µg.mL-1 with detection limit of 0.268µg.mL-1. The results show the absence of interferences from the excipients on the determination of the drug. Therefore the proposed method has been successfully applied for the determination of cimetid
... Show MorePower-electronic converters are essential elements for the effective interconnection of renewable energy sources to the power grid, as well as to include energy storage units, vehicle charging stations, microgrids, etc. Converter models that provide an accurate representation of their wideband operation and interconnection with other active and passive grid components and systems are necessary for reliable steady state and transient analyses during normal or abnormal grid operating conditions. This paper introduces two Laplace domain-based approaches to model buck and boost DC-DC converters for electromagnetic transient studies. The first approach is an analytical one, where the converter is represented by a two-port admittance model via mo
... Show MoreAims: This study aimed to assess complications of caesarean section among pregnant women attending AL Diwaniyah Maternity and Pediatric Hospital; and find out relationship between complications of caesarean section and socio-demographic data of women. Methods: A descriptive cross-sectional study design is conducted for the period of December 26th 2020 to June 1st 2021. The validity of the questionnaire is determine through a panel of experts and reliability was achieved through a pilot study. By a purposive sample is selected among pregnant women who undergo caesarean section, data was collected through the use of questionnaire and interview techniques; and analyzed through the descriptive and inferential statistic. Results: Findings indica
... Show MoreThe current research reports the preparation and fabrication of the silver paste conductor which is employed as a soldering material for electro – optical components ohmic interconnections. The prepared paste possesses electrical characteristics identical to the ohmic connectors as its observable from resistance – temperature variation. Moreover, the I – V characteristics obeys Ohm’s law and this dependency was further confirmed by the nearly constant capacitance measurements with voltage and frequency. A noticeable improvement in electrical conductivity, compared to the pure silver paste sample, was noted for samples prepared by mixing predetermined weight ratios of brass and copper. Furthermore, stability of electrical resistan
... Show More