Forty-four bottles of drinking water were collected from the local markets of Basra City and stored in the laboratory refrigerator at 4ºC until the physical, chemical and biological measurements were carried out. The results showed a discrepancy in the compatibility of the specifications written on the drinking water bottle label with the sample measurements as well as the variation in the results with the Iraqi standards for bottled water. The percentage of bottled water that is not safe for drinking was 88.5% of the total samples of the study. This value is high and an indication of lack of control over marketing from the imported or produced in the local labs, so it is a danger to the health of the consumer. Results showed that the PH ranged 6.5–8 and did not exceed the values on the information sheet of the potable drinking water as well as the TDS, chloride, magnesium; nitrate and potassium which were within the permissible limits. In addition, the results showed that calcium, total hardness, fluoride and bacterial growth values exceeded the permissible limits, and there are different significations between factors in samples.
RKRAS L. K. Abdul Karem, F. H. Ganim, Biochemical and Cellular Archives, 2018 - Cited by 2
Objectives: To evaluate the effect of vitamin D3 local injections on apical root resorption, alveolar bone integrity, and chair-side time following three and six months of canine retraction. Subjects and Methods: Seventeen adult patients (18-35 years old) of class I and II malocclusions were recruited, who required bilateral maxillary 1st premolars extraction before starting maxillary canines retraction. The experimental side received 25 pg dose of vitamin D3 injected locally into the distal periodontal sulcus of the canine (before force application) every three weeks, while the control side received retraction force only. Periapical radiographic evaluation was conducted after 3 and 6 months of the start of canines' retraction. Results: At
... Show MoreMJ Abbas, AK Hussein, Journal of Physical Education, 2019
A simple, rapid and environmentally friendly dispersive liquid–liquid microextraction method-based spectrophotometric method for the trace determination of folic acid has been developed. The proposed method is based on the formation of a deep yellow product via reaction of folic acid and 1,2-naphthoquine-4-sulfonate at pH = 9. The formed complex was extracted using a mixture of chloroform and ethanol. Then, the tiny organic droplets were measured at λ = 520 nm. At the optimum conditions, linearity was ranged from 0.05 to 1.5 μg/mL for the standard and samples, with a linear correlation coefficient of 0.9996. The detection limits were 0.02, 0.027, 0.03, 0.02 and 0.04 μg/mL for standard, tablet (5 mg), tablet (1 mg), syrup and fl
... Show MoreThe special core analysis tests were accomplished on a set of core plugs for Mishrif Formation (mA, mB1, and mB2cde/mC units) in West Qurna/1 oilfield, southern Iraq. Oil relative permeability (Kro) data and the Corey-type fit of the data as functions of the brine saturation at the core outlet face for individual samples in the water-oil imbibition process to estimate relative permeability measurements by the centrifuge method were utilized. Identical correlations for oil and water relative permeabilities were extracted by steady-state and unsteady-state methods. For the mA samples, the gas-water capillary pressure curves were within a narrow range (almost identical) indicating that mA is a homogeneous unit. Kro curves for three mB2
... Show MoreA simple, sensitive and rapid method was used for the estimate of: Propranolol with Bi (III) to prove the efficiency, reliability and repeatability of the long distance chasing photometer (NAG-ADF-300-2) using continuous flow injection analysis. The method is based on a reaction between propranolol and Bi (III) in an aqueous medium to obtain a yellow precipitate. Optimum parameters were studied to increase the sensitivity for the developed method. A linear range for calibration graph was 0.1-25 mmol/L for cell A and 1-40 mmol/L for cell B, and LOD 51.8698 ng/200 µL and 363.0886 ng /200 µL , respectively to cell A and cell B with correlation coefficient (r) 0.9975 for cell A, 0.9966 for cell B, RSD% was lower than 1%, (n = 8) for the
... Show MoreThe study sought to identify the attitudes of PhD students towards establishing the field of educational administration. The study followed the descriptive survey method. The questionnaire was used to collect information from the study community consisting of (95) male and female students in the department of educational administration and Planning. Among the most important results about students ’attitudes towards establishing the educational administration field are the following: 1) identifying the necessity of establishing the educational administration field. 2) Encouraging students to attend seminars and scientific conferences in Islamic rooting. 3) there are no statistically significant differences in the attitudes of doctoral s
... Show More