In this research, a new technique is suggested to reduce the long time required by the encoding process by using modified moment features on domain blocks. The modified moment features were used in accelerating the matching step of the Iterated Function System (IFS). The main disadvantage facing the fractal image compression (FIC) method is the over-long encoding time needed for checking all domain blocks and choosing the least error to get the best matched domain for each block of ranges. In this paper, we develop a method that can reduce the encoding time of FIC by reducing the size of the domain pool based on the moment features of domain blocks, followed by a comparison with threshold (the selected threshold based on experience is 0.0001). The experiment was conducted on three images with size of 512x512 pixel, resolution of 8 bits/pixel, and different block size (4x4, 8x8 and, 16x16 pixels). The resulted encoding time (ET) values achieved by the proposed method were 41.53, 39.06, and 38.16 sec, respectively, for boat , butterfly, and house images of block size 4x4 pixel. These values were compared with those obtained by the traditional algorithm for the same images with the same block size, which were 1073.85, 1102.66, and 1084.92 sec, respectively. The results imply that the proposed algorithm could remarkably reduce the ET of the images in comparison with the traditional algorithm.
Water quality sensors have recently received a lot of attention due to their impact on human health. Due to their distinct features, environmental sensors are based on carbon quantum dots (CQDs). In this study, CQDs were prepared using the electro-chemical method, where the structural and optical properties were studied. These quantum dots were used in the environmental sensor application after mixing them with three different materials: CQDs, Alq3 polymer and CQDs and Alq3 solutions using two different methods: drop casting and spin coating, and depositing them on silicon. The sensitivity of the water pollutants was studied for each case of the prepared samples after measuring the change in resistance of the samples at a temperature of
... Show MoreThe aim of research is to show the effect of Ferric Oxide (Fe2O3) on the electricity production and wastewater treatment, since 2.5% of Ferric Oxide (Fe2O3) (heated and non heated) nanoparticles has been used. Characterization of nanoparticles was done using X-ray Diffraction (XRD) and Scan Electron Microscopy (SEM). The influence of acidity was also studied on both wastewater treatmenton the Chemical Oxygen demand (COD) and Biological Oxygen Demand (BOD) and voltage output was studied. From the results, it was infused that the dosage of 0.025 g/l and an initial pH 7 were founded to be optimum for the effective degradation of effluents. The results concluded that the treatment of anaerobic sludge wastewater using Ferric Oxide (Fe2O3) in
... Show MoreGrapes and grape seeds are important samples employed for environmental medical studies . The air of this work was to identify and concentration calculation of the elements in grapes fruit and thier seeds by using X-Ray fluoresces technique (XRF) . Samples were collected from Abo Ghraib of Baghdad city ,the grape seeds were obtained from those samples . Both samples were taken under experimental procedure to obtain the sample which were ready for analysis . The samples were then submitted to experimental conditions using a radiation source and then samples were applied for counting analysis shows the elements Na , Mg , Al , Si , P , S , Cl , K , Ca , and Sr as major components of the samples. Fe , Sr , I , Ba and V were
... Show MoreThis paper concerned with estimation reliability ( for K components parallel system of the stress-strength model with non-identical components which is subjected to a common stress, when the stress and strength follow the Generalized Exponential Distribution (GED) with unknown shape parameter α and the known scale parameter θ (θ=1) to be common. Different shrinkage estimation methods will be considered to estimate  depending on maximum likelihood estimator and prior estimates based on simulation using mean squared error (MSE) criteria. The study approved that the shrinkage estimation using shrinkage weight function was the best.
Undoped and Al-doped CdO thin films have been prepared by vacuum thermal evaporation on glass substrate at room temperature for various Al doping ratios (0.5, 1 and 2)wt.% . The films are characterized by XRD and AFM surface morphology properties. XRD analysis showed that CdO:Al films are highly polycrystalline and exhibit cubic crystal structure of lattice constant averaged to 0.4696 nm with (111) preferred orientation. However, intensity of all peaks rapidly decreases which indicates that the crystallinity decreases with the increase of Al dopant. The grain size decreases with Al content (from 60.81 to 48.03 nm). SEM and AFM were applied to study the morphology an
... Show More
In this work, a novel technique to obtain an accurate solutions to nonlinear form by multi-step combination with Laplace-variational approach (MSLVIM) is introduced. Compared with the traditional approach for variational it overcome all difficulties and enable to provide us more an accurate solutions with extended of the convergence region as well as covering to larger intervals which providing us a continuous representation of approximate analytic solution and it give more better information of the solution over the whole time interval. This technique is more easier for obtaining the general Lagrange multiplier with reduces the time and calculations. It converges rapidly to exact formula with simply computable terms wit
... Show MoreThe objective of this research is to select the most suitable drilling location of new groundwater exploration wells, with a decision-making tool from Geographic Information System (GIS). The optimum location will be evaluated base on the hydro-geoelectrical parameter derived from Vertical Electrical Sound (VES) including Longitudinal Conductance, the thickness of the aquifer, the apparent resistivity and Transmissivity. From the Geo-electrical method (VES) the finds shows that the aquifers in the study area have Apparent Resistivity ranging from 0.32 to 40.24 Ωm, Thickness between 0.21 m to 15.06 m, Longitudinal Conductance ranging from 0.006 to 10.246Ω-1 and Transmissivity ranging from 0.14 to
... Show More