Non-thermal plasma(Dielectric barrier discharge) has many uses including living tissue sterilization, inactivation of the bacteria, excimer formation, angiogenesis, and surface treatment. This research aim is to use cold plasma as a tool to search the effect of the dielectric barrier discharge system at room temperature on human sperm motility and DNA integrity. This work was performed on 60 human semen samples suffering from low motility; each sample was prepared by centrifugation method, then each semen sample was divided into two sections, the first section is before significant exposure to the plasma system (DBD) and the second section is after treatment with the DBD system at ambient temperature. Before and after exposure to non-thermal Plasma (DBD), DNA integrity and sperm motility were assessed, patients suffered from asthenospermia has a high level of DNA fragmentation than fertile male, ( 24.16±4.14) p<0.001 for untreated and after treatment the semen slide with dielectric barrier discharge the percentage decreases to (9.16±1.76) p>0.006, and the comet slide was (35.44±4.15) then the percentage decline to (19.86 ±2.44) these results have shown that cold plasma improves sperm motility and decreases from DNA damage in patients with medium and high level of DNA damage.
In this research, the effect of electrode material on the parameters of the produced DBD plasma was investigated. First, a non-thermal plasma was created by applying a 15 kV AC voltage between two electrodes and using a glass plate as a dielectric barrier in the design Dielectric Barrier Discharge (DBD) plasma system. The obtained plasma spectrum was analyzed using optical emission spectroscopy to calculate plasma parameters by the Boltzmann plot method. Electrodes made of copper, aluminium, and stainless steel were employed in this research. Electron temperature ( ) for copper, aluminium, and stainless steel was found to be (1.398 eV), (1.093 eV) and (1.009 eV), respectively.
The development in the field of medical physics has led to the use of devices that
are manufactured under normal conditions to make tremendous progress in the
world of development in medical treatment by using these devices with modern
techniques by reducing the use of antibiotics and relying on these tools and devices
that link between physics and modern therapeutic medicine. In this research, a nonthermal
plasma system for argon gas operated at normal atmospheric pressure was
designed, this system was applied on Pseudomonas Aeruginosa bacteria isolated
from burn patients from Yarmouk Teaching Hospital. These bacteria were exposed
to this system, the results showed that these bacteria were killed at time (5 min)
Non-thermal (low-temperature) plasma may act as an alternative approach to control superficial wound and skin infections when the effectiveness of chemical agents is weak due to natural pathogen or biofilm resistance. In this paper an atmospheric pressure plasma needle jet device which generates a cold plasma jet is used to measure the effectiveness of plasma treatment against different pathogenic bacteria and to test the individual susceptibility of pathogenic bacteria to non-thermal argon plasma. It is found that, Gram-negative bacteria were more susceptible to plasma treatment than Gram-positive bacteria. For the Gram-negative bacteria Pseudomonas aeruginosa, there were no survivors among the initial 1x108C.F.U (Co
... Show MoreBackground: The effect of Helium Neon laser (He-Ne 632.8 nm) was reported to protect cells from damage. We studied lymphocyte cells pre irradiated with (UVC 260 nm) to induce DNA damage. Investigations were carried using gel electrophoresis and test for cell viability. It has also been reported that effect depends on incubation period after damage. The extent of damage to the cells depends on the period of irradiation with UVC also on its intensity.
Objective: In this work we studied the effect of UVC on DNA damage and cell survival
Also study of the effect of He-Ne laser on cell survival after all being pre irradiated with UVC light and its protective effect on DNA post UV damage.
Method: This study was conducted in pathology d
In this research, a non-thermal plasma system was designed and a non-thermal plasma needle was manufactured for argon gas operating at normal atmospheric pressure. The electrical description of this system studied by using two different values of voltages (4.9,8) kV. Where the results showed the small amount of electrical current consumed by the system of plasma needle up to several microns of amps, and the value of the electrical current increase with the increasing gas flow, as well as the results, showed that happen a breakdown voltage at (8) kV when gas flow (4 l/min) causing a slight decrease in the electrical current value.
The objective of this study was to investigate and find the relationships between human semen osmolality and oxidative stress with semen quality. Semen analysis was determined to evaluate semen quality and fertility. The concentration of semen malondialdehyde (MDA) was measured to assess oxidative stress. For this purpose, one hundred seventy healthy adult males were used in this study. The study was conducted from September 2018 to November 2019 in the Infertility care and in vitro fertilization center (IVF) and the Biology department of the College of Science at Salahaddin University in Erbil city. A significant positive correlation was observed between the total sperm motility, grade activity, and sperm motility index with semen osmol
... Show MoreBiofilm formation represents one of the biggest problems facing scientists because of this phenomenon linkage with virulence of bacteria and other clinical environmental problems. In the present study, two clinical isolates,
Escherichia coli, and Staphylococcus aureus were exposed to the non thermal plasma for different intervals of time (1, 2, 4, 8, and 16 min). The biofilm was measured post exposing. It was found that 2 min. exposing to non-thermal plasma reduced the biofilm formation by both clinical isolates significantly. It can be concluded that the ability of S. aureus to form biofilm higher than E. coli and exposing for 2 min to non-thermal plasma sufficient to reduce the biofilm formati
Recently, research has focused on non-thermal plasma (NTP) technologies as a way to remove volatile organic compounds from the air stream, due to its distinctive qualities, which include a quick reaction at room temperature. In this work, the properties of the plasma generated by the dielectric barrier discharge (DBD) system and by a glass insulator were studied. Plasma was generated at different voltages (3, 4, 6, 7, 8 kV ) with a fixed distance between the electrodes of 5 mm, and a constant argon gas flow rate of (2.5) I/min. DBD plasma emission spectra were recorded for each voltage. The Boltzmann plot method was used to calculate the electron temperature in the plasma ( ), and the Stark expansion method was used to calculate the elec
... Show MoreThe work demonstrates the effect of cold atmospheric plasma (CAP) on adult female rats suffering from osteoporosis, the used plasma was generated by a floating electrode-dielectric barrier discharge system with an electrode diameter of 3 cm. The output power was from (12-20) watts. The effect of non-thermal plasma was observed on rats with various exposure times of 20, 30, and 40 sec. It was noted that the blood calcium percentage of animals exposed to cold plasma increased, as well as an increase in the level of vitamin D3 at the same time, it is noted that there is no effect on parathyroid hormone level. For the thyroid gland, it is noticed an increase in the level of T3, and T4 hormones in the blood during the period of induction for
... Show MoreBackground: To determine the DNA content in subfertile patients and to correlate it with seminal sperm concentration.
Design: Prospective observational study.
Setting: College of Medicine, Dept. of Physiological chemistry and Institute for embryo Research and infertility treatment-University of Baghdad.The study was conducted
through years 2004-2005.
Methods: A random sample of 61 subfertile male patients undergoing semen evaluation and aged from 20-45 years were studied. Semen samples were assessed for seminal sperm
concentration microscopically and were classified into 3 different groups according to count (million/ml).Then sperm D N A content (μg/ml) was estimated using a microchemical
spectropho