Non-thermal (low-temperature) plasma may act as an alternative approach to control superficial wound and skin infections when the effectiveness of chemical agents is weak due to natural pathogen or biofilm resistance. In this paper an atmospheric pressure plasma needle jet device which generates a cold plasma jet is used to measure the effectiveness of plasma treatment against different pathogenic bacteria and to test the individual susceptibility of pathogenic bacteria to non-thermal argon plasma. It is found that, Gram-negative bacteria were more susceptible to plasma treatment than Gram-positive bacteria. For the Gram-negative bacteria Pseudomonas aeruginosa, there were no survivors among the initial 1x108C.F.U (Colony Forming Unit) after a 40 seconds plasma treatment. The susceptibility of Gram-positive bacteria and the Gram-negative bacteria were species and strain specific. Staphylococcus aureus was the most resistant with 4.5 % survival of the initial 2x106C.F.U. after a 40 seconds plasma treatment. According to species, Staphylococcus aureus had a strain-dependent resistance with 39% and 99% reduction from 2x106C.F.U.of the five studied isolates, respectively, whereas, Escherichia coli had a lower resistance with 76% and 99% reduction after 40 seconds.
Cold plasma is a relatively low temperature gas, so this feature enables us to use cold plasma to treat thermally sensitive materials including polymers and biologic tissues. In this research, the non-thermal plasma system is designed with diameter (3 mm, 10 mm) Argon at atmospheric pressure as well as to be suitable for use in medical and biotechnological applications.
The thermal description of this system was studied and we observed the effect of the diameter of the plasma needle on the plasma, when the plasma needle slot is increased the plasma temperature decrease, as well as the effect of the voltages applied to the temperature of the plasma, where the temperature increasing with increasing the applied voltage . Results showed t
In this research, a non-thermal plasma system was designed and a non-thermal plasma needle was manufactured for argon gas operating at normal atmospheric pressure. The electrical description of this system studied by using two different values of voltages (4.9,8) kV. Where the results showed the small amount of electrical current consumed by the system of plasma needle up to several microns of amps, and the value of the electrical current increase with the increasing gas flow, as well as the results, showed that happen a breakdown voltage at (8) kV when gas flow (4 l/min) causing a slight decrease in the electrical current value.
The development in the field of medical physics has led to the use of devices that
are manufactured under normal conditions to make tremendous progress in the
world of development in medical treatment by using these devices with modern
techniques by reducing the use of antibiotics and relying on these tools and devices
that link between physics and modern therapeutic medicine. In this research, a nonthermal
plasma system for argon gas operated at normal atmospheric pressure was
designed, this system was applied on Pseudomonas Aeruginosa bacteria isolated
from burn patients from Yarmouk Teaching Hospital. These bacteria were exposed
to this system, the results showed that these bacteria were killed at time (5 min)
Non-thermal argon plasma needle at atmospheric pressure was
constructed. The experimental setup was based on a simple and low
cost electric component that generates a sufficiently high electric
field at the electrodes to ionize the argon gas which flow at
atmospheric pressure. A high AC power supply was used with 1.1
kV and 19.57 kHz. Non-thermal Argon plasma used on blood
samples to show the ability of non-thermal plasma to promote blood
coagulation. Three tests have been done to show the ability of plasma
to coagulate both normal and anti-coagulant blood. Each blood
sample has been treated for varying time from 20sec. to 180sec. at
different distances. The results of the current study showed that the
co
Background: In the present study used device jet plasma needle with atmospheric pressure which generates non thermal plasma jet to measure treatment potent with plasma against pathogenic bacteria founded in UTI was inactivated with plasma at 10 sec,
Objective:. This work included the application of the plasma produced from the system in the field of bacterial sterilization , where sample of Gram- negative bacteria (Escherichia coli) were exposed to intervals (1-10)second . Midstream Urine samples swabs were obtained from patients with urinary tract infections.
Type of the study: Cross -sectional study.
Methods: The work were used i
... Show MoreNon-thermal atmospheric pressure plasma has emerged as a
new promising tool in medicine and biology. In this work, A DBD
system was built as a source of atmospheric pressure non-thermal
Plasma suitable for clinical and biological applications. E. coli and
staphylococcus spp bacteria were exposed to the DBD plasma for a
period of time as inactivation (sterilization) process. A series of
experiments were achieved under different operating conditions. The
results showed that the inactivation, of the two kinds of bacteria, was
affected (increasing or decreasing) according to operation conditions
because they affects, as expected, the produced plasma properties
according to those conditions.
Biofilm formation represents one of the biggest problems facing scientists because of this phenomenon linkage with virulence of bacteria and other clinical environmental problems. In the present study, two clinical isolates,
Escherichia coli, and Staphylococcus aureus were exposed to the non thermal plasma for different intervals of time (1, 2, 4, 8, and 16 min). The biofilm was measured post exposing. It was found that 2 min. exposing to non-thermal plasma reduced the biofilm formation by both clinical isolates significantly. It can be concluded that the ability of S. aureus to form biofilm higher than E. coli and exposing for 2 min to non-thermal plasma sufficient to reduce the biofilm formati
Non-thermal plasma(Dielectric barrier discharge) has many uses including living tissue sterilization, inactivation of the bacteria, excimer formation, angiogenesis, and surface treatment. This research aim is to use cold plasma as a tool to search the effect of the dielectric barrier discharge system at room temperature on human sperm motility and DNA integrity. This work was performed on 60 human semen samples suffering from low motility; each sample was prepared by centrifugation method, then each semen sample was divided into two sections, the first section is before significant exposure to the plasma system (DBD) and the second section is after treatment with the DBD system at ambient temperature. Before and after exposure to non-the
... Show MoreNon thermal argon plasma needle at atmospheric pressure was constructed. The experimental set up was based on simple and low cost electric components that generate electrical field sufficiently high at the electrodes to ionize various gases which flow at atmospheric pressure. A high AC power supply was used with 9.6kV peak to peak and 33kHz frequency. The plasma was generated using two electrodes. The voltage and current discharge waveform were measured. The temperature of Ar gas plasma jet at different gas flow rate and distances from the plasma electrode was also recorded. It was found that the temperature increased with increasing frequency to reach the maximum value at 15 kHz, and that the current leading the voltage, which demonstra
... Show MoreTwo hundred fifty mid-stream urine specimens were collected from Baqubah Teaching Hospital and Al-Batool Teaching Hospital from patients with urinary tract infections (UTI). Of these investigated urine specimens, 66 (26.4%) specimens showed positive growth culture of Gram-negative bacteria. From these, Escherichia coli was the most prevalent bacteria of the examined culture (41, 62.12%). Additionally, the cup assay was used to determine colicin producers while the most efficient colicin producers were estimated by the formation of larger inhibition zone. Approximately half of the investigated E. coli isolates (20, 49 %) was colicin producers. Colicins was extracted after induction by mitomycin-C showed a concentration o
... Show More