The present study was designed to show the potential role of Matricaria chamomilla flower extract against toxicity of Entamoeba histolytica . The study used 20 adult albino male rats that divide randomly to four groups (each group consist 5 rats); control group received ad libidium, group of rats administrated with 1X103 cyct/ml suspension for seven days, group of rats administrated with 1X103 cyct/ml suspension and treated with 50mg/kg extract for month, group of rats administrated with 1X103 cyct/ml suspension and treated with 100mg/kg extract for month. The results show high significant increased (P < 0.05) in levels of Alanine Aminotransferase (ALT), Aspartate Aminotransferase (AST), Alkaline Phosphatase (ALP), urea, creatinine and uric acid in rats administrated with 1X103 cyct/ml suspension. Oxidative stress factor in this group show significant increased (P < 0.05) in levels of MDA (malonedialdehyied) and significant decreased (P < 0.05) in levels of glutathione (GSH) and catalase compared with control group. While, after used M. chamomilla flower extract with Entamoeba histolytica , the results showed non significant changes (P < 0.05) in liver and kidneys function parameters. Also, MDA, GSH and catalase showed non significant changes (P < 0.05) compared with control group. It was concluded that flower extract has been potential role against toxicity of Entamoeba histolytica in adult male albino rats.
This study depicts the removal of Manganese ions (Mn2+) from simulated wastewater by combined electrocoagulation/ electroflotation technologies. The effects of initial Mn concentration, current density (C.D.), electrolysis time, and different mesh numbers of stainless steel screen electrodes were investigated in a batch cell by adopting Taguchi experimental design to explore the optimum conditions for maximum removal efficiency of Mn. The results of multiple regression and signal to noise ratio (S/N) showed that the optimum conditions were Mn initial concentration of 100 ppm, C.D. of 4 mA/cm2, time of 120 min, and mesh no. of 30 (wire/inch). Also, the relative significance of each factor was attained by the analysis
... Show MoreErratum for Organic acid concentration thresholds for ageing of carbonate minerals: Implications for CO2 trapping/storage.
This study depicts the removal of Manganese ions (Mn2+) from simulated wastewater by combined electrocoagulation/ electroflotation technologies. The effects of initial Mn concentration, current density (C.D.), electrolysis time, and different mesh numbers of stainless steel screen electrodes were investigated in a batch cell by adopting Taguchi experimental design to explore the optimum conditions for maximum removal efficiency of Mn. The results of multiple regression and signal to noise ratio (S/N) showed that the optimum conditions were Mn initial concentration of 100 ppm, C.D. of 4 mA/cm2, time of 120 min, and mesh no. of 30 (wire/inch). Also, the relative significance of each factor was attained by the analysis of variance (ANO
... Show More
هدٌفت الد ا رسة إل هعرفة تأثير الهستخمص الزيتي لىبات الدارسين
Cinnamomum zeylanicum عم بعض الجكاىب الفسمجية كالىس جية في الفئ ا رف الهخهجة بالأكياس العذرية أك الطكر اليرقي لمهشككة
الحبيبية Echinococcus granulosus .كتقيي كفاءة الهستخمص الزيتي لىبات الدارسيف ضد الإصابة
التجريبية بالأكياس الهائية العذرية. استخد 40 فأ ا ر قسهت إل أربع هجاهيع هتساكية .حقىت الفئ ا رف في
الهجكعة الأكل كالثاىية كالثالثة ب 2000 رؤيس أكلي / فأر ،
A new, simple, sensitive and fast developed method was used for the determination of methyldopa in pure and pharmaceutical formulations by using continuous flow injection analysis. This method is based on formation a burgundy color complex between methyldopa andammonium ceric (IV) nitrate in aqueous medium using long distance chasing photometer NAG-ADF-300-2. The linear range for calibration graph was 0.05-8.3 mmol/L for cell A and 0.1-8.5 mmol/L for cell B, and LOD 952.8000 ng /200 µL for cell A and 3.3348 µg /200 µL for cell B respectively with correlation coefficient (r) 0.9994 for cell A and 0.9991 for cell B, RSD % was lower than 1 % for n=8. The results were compared with classical method UV-Spectrophotometric at λ max=280 n
... Show MoreThe gas sensing properties of Co3O4and Co3O4:Y nano structures were investigated. The films were synthesized using the hydrothermal method on a seeded layer. The XRD, SEM analysis and gas sensing properties were investigated for Co3O4and Co3O4:Y thin films. XRD analysis shows that all films are polycrystalline in nature, having a cubic structure, and the crystallite size is (11.7)nm for cobalt oxide and (9.3)nm for the Co3O4:10%Y. The SEM analysis of thin films obviously indicates that Co3O4possesses a nanosphere-like structure and a flower-like structure for Co3O4:Y.The sensitivity, response time and recovery time to a H2S reducing gas were tested at different operating
... Show MoreThe comparison of double informative priors which are assumed for the reliability function of Pareto type I distribution. To estimate the reliability function of Pareto type I distribution by using Bayes estimation, will be used two different kind of information in the Bayes estimation; two different priors have been selected for the parameter of Pareto type I distribution . Assuming distribution of three double prior’s chi- gamma squared distribution, gamma - erlang distribution, and erlang- exponential distribution as double priors. The results of the derivaties of these estimators under the squared error loss function with two different double priors. Using the simulation technique, to compare the performance for
... Show MoreTwo well-known fluorescent molecules: fluorescein sodium salt (FSS) and 2,7-dichloro fluorescein (DCF) were tried to prove the efficiency, trustability and repeatability of ISNAG fluorimeter by using discrete and continuous flow injection analysis modes.A linear range of 0.002-1 mmol/L for FSS and 0.003-0.7 mmol/L was for DCF, with LOD 0.0018 mmol/L and 0.002 mmol/L for FSS and DCF respectively, were obtained for discrete mode of analysis. While the continuous mode gave a linear range of 0.002-0.7 mmol/L and 0.003-0.5 mmol/L for FSS and DCF respectively, the LOD were 0.0016mmol/L and 0.0018 mmol/L for FSS and DCF respectively. The results were compared with classical method at variable λex for both fluorescent molecules at 95
... Show More