An R-module M is called ET-H-supplemented module if for each submodule X of M, there exists a direct summand D of M, such that T⊆X+K if and only if T⊆D+K, for every essential submodule K of M and T M. Also, let T, X and Y be submodules of a module M , then we say that Y is ET-weak supplemented of X in M if T⊆X+Y and (X⋂Y M. Also, we say that M is ET-weak supplemented module if each submodule of M has an ET-weak supplement in M. We give many characterizations of the ET-H-supplemented module and the ET-weak supplement. Also, we give the relation between the ET-H-supplemented and ET-lifting modules, along with the relationship between the ET weak -supplemented and ET-lifting modules.
A newly developed analytical method characterized by its speed and sensitivity for the determination of metoclopramide hydrochloride (MCP-HCl) in pure and pharmaceutical preparation via turbidimetric measurement (0-180o) by Ayah 6SX1-T-2D Solar cell-CFI Analyser. The method was based on the reaction of phosphomolybdic acid with metoclopramide hydrochloride in acidic medium to form yellowish white precipitate for the ion-pair complex. Turbidity was measured via the reflection of incident light that collides on the surface precipitated particles at 0-180o. Chemical and physical parameters were studied and optimized. The calibration graph was linear in the range of 0.0005-3 or 0.0005- 4 mMol.L-1, with correlation coefficient r = 0.9947&
... Show MoreA new Turbidimetric method characterized by simplicity, accuracy and speed for determination of iron(III) in drug samples by continuous flow injection analysis. The method was based on the formation of complex for iron(III) with 8-hydroxyquinoline in presence of ammonium acetate as a medium for the formation of deep green precipitate and this precipitate was determined using homemade Linear Array Ayah-5SX1-T-1D continuous flow injection analyser. The optimum parameters were 2.6 mL.min-1 flow rate using H2O as a carrier, 1.9 mL.min-1 (14 mmol.L-1) ammonium acetate, 2.4 mL.min-1 (14 mmol.L-1) 8-hydroxyquinoline, 60 L sample volume and open valve for the purge of the sample segment. Data treatment shows that linear range 0.1-8.0 mmol.L-1
... Show MoreA new turbidimetric-flow injection method is described for the determination of chlorpromazine HCl in pure and pharmaceutical preparation. The method is characterized by simplicity, sensitivity and fast, it is based on formation of ion pair compound between chlorpromazine HCl and Potassium hexacyanoferrate(III) in an acid medium for the formation of greenish yellow precipitate. This precipitate was determined using homemade Linear Array Ayah 5SX1-T-1D continuous flow injection analyser. Optimum concentrations of chemical reactants, physical instrumental conditions have been investigated. The linear dynamic range of chlorpromazine HCl was 3-30 mmol.L-1 while correlation coefficient (r) was 0.9929 and percentage linearity (%r2) C.O.D was 9
... Show MoreExperimental measurements were done for characterizing current-voltage and power-voltage of two types of photovoltaic (PV) solar modules; monocrystalline silicon (mc-Si) and copper indium gallium di-selenide (CIGS). The conversion efficiency depends on many factors, such as irradiation and temperature. The assembling measures as a rule cause contrast in electrical boundaries, even in cells of a similar kind. Additionally, if the misfortunes because of cell associations in a module are considered, it is hard to track down two indistinguishable photovoltaic modules. This way, just the I-V, and P-V bends' trial estimation permit knowing the electrical boundaries of a photovoltaic gadget with accuracy. This measure
... Show MoreTrue random number generators are essential components for communications to be conconfidentially secured. In this paper a new method is proposed to generate random sequences of numbers based on the difference of the arrival times of photons detected in a coincidence window between two single-photon counting modules
A newly developed analytical method characterized by its speed and sensitivity for the determination of metoclopramide hydrochloride (MCP-HCl) in pure and pharmaceutical preparations via absorbance measurement by Ayah 6SX1-T-2D Solar cell-CFI Analyser. The method is based on the oxidation of the drug with Ce(IV)sulfate in acidic medium to form a red color species which determined using homemade Ayah 6SX1-T-2D Solar cell . Chemical and physical parameters were studied and optimized. The calibration graph was linear in the range of 0.05- 16 mMol.LP-1Pwith correlation coefficient r = 0.9855. The limit of detection(S/N = 3) 0.332 μg/sample from the step wise dilution for the minimum concentration in the linear dynamic ranged of the calibrat
... Show MoreA new simple sensitive and selective spectrophotometric method has been
developed for the analysis of vanadium(V) in three randomly chosen samples from
river water at different locations by continuous flow injection analysis. The method
based on the oxidation of pyrogallol by vanadium(V) in acidic solution to form color
species and the same species was determined using homemade Ayah 6SX1-T-2D
solar cell analyser . Chemical and physical parameters were investigated using the
high intensity of snow white light emitted diode as a source. The linear dynamic
range for the instrument response versus vanadium(V) concentration was 1-200
mg.L-1 with correlation coefficient r = 0.9920. The limit of detection (S/N=3) was 70<
A newly developed analytical method characterized by its speed and sensitivity for
the determination of cadmium (II) in aqueous solution in three randomly chosen
samples from river water at different locations via turbidimetric measurement by
Ayah 6SX1-T-2D Solar - CFI analyser. The method is based on the formation of
yellowish white precipitate for the complex Cd3[Fe(CN)6]2 by direct reaction of the
cadmium (II) with potassium hexacyano ferrate (III) in aqueous medium. Turbidity
was measured via the reflection of incident light that collides on the surfaces
precipitated particles at 0-180o. Chemical and physical parameters were investigated.
Linear dynamic of cadmium (II) is ranged from 0.05-12 mmol.L-1, with cor