In this work, a chemical optical fiber sensor based on Surface Plasmon Resonance (SPR) was designed and implemented using plastic optical fiber. The sensor is used for estimating refractive indices and concentrations of various chemical materials (methanol, distilled water, ethanol, kerosene) as well as for evaluating the performance parameters such as sensitivity, signal to noise ratio, resolution and the figure of merit of the fabricated sensor. It was found that the value of the sensitivity of the optical fiber-based SPR sensor, with 40 nm thick and 10 mm long Au metal film of exposed sensing region, was 3μm/RIU, while the SNR was 0.24, the figure of merit was 20, and the resolution was 0.00066. The sort of optical fiber utilized in this work is plastic optical fiber with a core diameter of 980 μm, a fluorinated polymer cladding of 20μm and a numerical aperture of 0.51.
Thin films of CuPc of various thicknesses (150,300 and 450) nm have been deposited using pulsed laser deposition technique at room temperature. The study showed that the spectra of the optical absorption of the thin films of the CuPc are two bands of absorption one in the visible region at about 635 nm, referred to as Q-band, and the second in ultra-violet region where B-band is located at 330 nm. CuPc thin films were found to have direct band gap with values around (1.81 and 3.14 (eV respectively. The vibrational studies were carried out using Fourier transform infrared spectroscopy (FT-IR). Finally, From open and closed aperture Z-scan data non-linear absorption coefficient and non-linear refractive index have been calculated res
... Show MoreVideo copyright protection is the most generally acknowledged method of preventing data piracy. This paper proposes a blind video copyright protection technique based on the Fast Walsh Hadamard Transform (FWHT), Discrete Wavelet Transform (DWT), and Arnold Map. The proposed method chooses only frames with maximum and minimum energy features to host the watermark. It also exploits the advantages of both the fast Walsh Hadamard transform (FWHT) and discrete wavelet transforms (DWT) for watermark embedding. The Arnold map encrypts watermarks before the embedding process and decrypts watermarks after extraction. The results show that the proposed method can achieve a fast embedding time, good transparency, and robustness against various
... Show MoreIn this paper, the theoretical cross section in pre-equilibrium nuclear reaction has been studied for the reaction at energy 22.4 MeV. Ericson’s formula of partial level density PLD and their corrections (William’s correction and spin correction) have been substituted in the theoretical cross section and compared with the experimental data for nucleus. It has been found that the theoretical cross section with one-component PLD from Ericson’s formula when doesn’t agree with the experimental value and when . There is little agreement only at the high value of energy range with the experimental cross section. The theoretical cross section that depends on the one-component William's formula and on-component corrected to spi
... Show MoreThis contribution investigates the impact of adding transition metal of Ti to CeOy samples at various concentrations referring to 0, 15.84, 24.46, 34.46, 36.23, 38.46, 45.38% and pure TiOy, correspondingly. The samples were fabricated by the magnetron sputtering technique. X-ray diffraction (XRD) configurations demonstrate the presence of α-Ce2O3 and Ce2O3 phases with increased Ti contents in the systems. X-ray photoelectron spectroscopy (XPS) experimentation confirms the purity of the S1-sample (CeO2) and the purity of the S8-sample (TiO2). Further XPS analysis reveals that Ti incorporation in the doped systems functions as a reducing agent because of the existence of α-Ce2O3 and Ce2O3 phases. Moreover, based on UV–vis spectroscopy res
... Show MoreAn optical video communication system is designed and constructed using pulse frequency modulation (PFM) technique. In this work PFM pulses are generated at the transmitter using voltage control oscillator (VCO) of width 50 ns for each pulse. Double frequency, equal width and narrow pulses are produced in the receiver be for demodulation. The use of the frequency doubling technique in such a system results in a narrow transmission bandwidth (25 ns) and high receiver sensitivity.
In the present work, a z-scan technique was used to study the nonlinear optical properties, represented by the nonlinear refractive index and nonlinear absorption coefficients of nanoparticles cadmium sulfide thin film. The sample was prepared by the chemical bath deposition method. Several testing were done including, x-ray, transmission and thickness of thin film. z-Scan experiment was performed at two wavelengths (1064 nm and 532 nm) and different energies. The results showed the effect of self-focusing in the material at higher intensities, which evaluated n2 to be (0.11-0.16) cm2/GW. The effect of two-photon absorption was studied, which evaluated β to be (24-106) cm/GW. In addition, the optical limiting behavior has been studied.
... Show MoreTitanium dioxide (TiO2) Nano powder has been synthesized by hydrothermal method. The reaction took place between titanium tetrachloride (TiCI4) and mixture solution consisted of deionized water and ethanol, in the ratio (3:7) respectively. Structure and surface morphology of TiO2 Nano powder at different annealing temperatures in the range 200-800°C for 120 min were characterized by X-ray diffraction (XRD), Atomic Force Microscope (AFM), Scanning Electron Microscopy (SEM), FT-IR and UV/visible spectroscopy measurements. The results show that with an increase in annealing temperature, the value of the intensity of (110) peak for rutile phase increases while the value of the full-width at half maximum (FWHM) decreases, and the band gap de
... Show MoreThe major function of the kidney is the filtration and secretion of the final products of metabolism and the excess of electrolytes. The term kidney failure denotes inability of the kidneys to perform excretory function leading to retention of nitrogenous waste products from the blood. Biosensor are most accurate, with a rapid diagnosis ,more costly method than the traditional method to avoid any biological changes in blood sample that lead to changes optical characteristic (refractive index and absorption) of blood sample. The current study was designed to single mode more Sensitivity than multi mode for Biomarkers were recorded for Albumin 5447.06, 5193.93 and Urea sample 2623.14, 1998.44 in sm and mm respectively .
... Show MoreThis contribution investigates the impact of adding transition metal of Ti to CeOy samples at various concentrations referring to 0, 15.84, 24.46, 34.46, 36.23, 38.46, 45.38% and pure TiOy, correspondingly. The samples were fabricated by the magnetron sputtering technique. X-ray diffraction (XRD) configurations demonstrate the presence of α-Ce2O3 and Ce2O3 phases with increased Ti contents in the systems. X-ray photoelectron spectroscopy (XPS) experimentation confirms the purity of the S1-sample (CeO2) and the purity of the S8-sample (TiO2). Further XPS analysis reveals that Ti incorporation in the doped systems functions as a reducing agent because of the existence of α-Ce2O3 and Ce2O3 phases. Moreover, based on UV–vis spectroscopy res
... Show More