A simple, rapid and sensitive method for the analysis of Atenolol in pure and pharmaceutical preparation as an alternative analytical procedure were developed by continuous flow injection analysis via turbidimetric (T180o) and scattered light effect at two opposite position (2N90o). The method is based upon the formation of white precipitate for the ion pair compound by phosphomolybidic acid with Atenolol in aqueous medium. The precipitate is measured via the attenuation of incident light and scattering of the incident light in two opposite direction namely +90o and -90o angle were measured. Chemical and physical parameters were investigated. The linearity of Atenolol is ranged from (0.1-11) mmol.L-1, with correlation coefficient r=0.9938, lower limit of detection (LOD) 0.05 mmol.L-1(3SB)(S/N=3) for n=13 and the relative standard deviation for 7 mmol.L-1 Atenolol solution is lower than 3% (n=7). The method was applied successfully for the determination of atenolol in three pharmaceutical drugs. A comparisons were made between the newly developed method of analysis with the classical method ( uv-spectrophotometry at wave length 274nm) of analysis using the standard addition method via the use of t- test. It shows that there was no significant difference at α=0.05(95% confidence) between the two methods. Therefore the newly developed method can be accepted as an alternative method for the analysis of Atenolol, in addition to comparison between the official value and the calculated value for both methods
Background:
Angiogenesis plays a crucial role in tumorigensis; several reports have described a significant increase in microvessel density (MVD) in colorectal carcinogenesis There are
several methods to measure the angiogenesis in neoplasms, but immunohitochemistry seems to be the mainstay of all. This method enable us to measure the tumor microvessel densities highlighted by using antibodies directed against endothelial cell markers like CD31,CD34 or others; then assessment of MVD by manual count of the number of microvessels in what appears to be the most vascular area of the tumor(called the hot spot) using a protocol described by Weidner et al.Automated cellular imaging system is used to analyze
The present study develops an artificial neural network (ANN) to model an analysis and a simulation of the correlation between the average corrosion rate carbon steel and the effective parameter Reynolds number (Re), water concentration (Wc) % temperature (T o) with constant of PH 7 . The water, produced fom oil in Kirkuk oil field in Iraq from well no. k184-Depth2200ft., has been used as a corrosive media and specimen area (400 mm2) for the materials that were used as low carbon steel pipe. The pipes are supplied by Doura Refinery . The used flow system is all made of Q.V.F glass, and the circulation of the two –phase (liquid – liquid ) is affected using a Q.V.F pump .The input parameters of the model consists of Reynolds number , w
... Show MoreA UV-Vis spectrophotometry method was developed for the determination of metoclopramide hydrochloride in pure and several pharmaceutical preparations, such as Permosan tablets, Meclodin syrups, and Plasil ampoules. The method is based on the diazotization reaction of metoclopramide hydrochloride with sodium nitrate and hydrochloric acid to yield the diazonium salt, which is then reacted with 3,5-dimethyl phenol in the presence of sodium hydroxide to form a yellow azo dye. Calibration curves were linear in the range from 0.3 to 6.5 µg/mL, with a correlation coefficient of 0.9993. The limits of detection and quantification were determined and found to be 0.18 and 0.61 µg/mL, respectively. Accuracy and precision were also determined b
... Show MoreAn easy, eclectic, precise high-Performance Liquid Chromatographic (HPLC) procedure was evolved and validated to estimate of Piroxicam and Codeine phosphate. Chromatographic demarcation was accomplished on a C18 column [Use BDS Hypersil C18, 5μ, 150 x 4.6 mm] using a mobile phase of methanol: phosphate buffer (60:40, v/v, pH=2.3), the flow rate was 1.1 mL/min, UV detection was at 214 nm. System Suitability tests (SSTs) are typically performed to assess the suitability and effectiveness of the entire chromatography system. The retention time for Piroxicam was found to be 3.95 minutes and 1.46 minutes for Codeine phosphate. The evolved method has been validated through precision, limit of quantitation, specificity,
... Show MoreThis study aimed at comparing the performance of vertical, horizontal and hybrid subsurface flow systems in secondary treatment for the effluent wastewater from the primary basins at Al-Rustumia wastewater treatment plant, Baghdad, Iraq. The treatments were monitored for six weeks while the testsduration were from 4 to 12 September 2018 under continuous wastewater feeding for chemical oxygen demand (COD), total suspended solid (TSS),ammonia-nitrogen(NH4-N) and phosphate (PO4-P) in comparison with FAO and USEPA standards for effluent discharge to evaluate the suitability of treated water for irrigation purposes. Among the systems planted with Phragmites Australia, the hybrid subsurface flow system which cons
... Show MoreTwo simple, sensitive, accurate and economic methods A and B have been developed for the quantitative estimation of vancomycin hydrochlorid (VHC) and its formulations using another two drug compounds as a coupling reagents.The proposed methods are based on a coupling reaction between VHC and diazotized procain (method A) or diazotized sulphacetamide sodium (method B) in alkaline medium to form intense yellow, water-soluble dyes that are very stable and have a maximum absorption at 447 and 439 nm for methods A and B respectively. Regression analysis of Beer’s law plots showed good correlation in the concentration ranges 1-28 and 1-45 μg ml-1 for methods A and B, respectively with a molar absorbtivity of 4.605×104 L mol-1cm-1 and 4.516
... Show MoreA simple, accurate, precise, rapid, economical and a high sensitive spectrophotometric method has been developed for the determination of tadalafil in pharmaceutical preparations and industrial wastewater samples, which shows a maximum absorbance at 204 nm in 1:1 ethanol-water. Beer's law was obeyed in the range of 1-7?g/ mL ,with molar absorptivity and Sandell ? s sensitivity of 0.783x105l/mol.cm and 4.97 ng/cm2respectively, relative standard deviation of the method was less than 1.7%, and accuracy (average recovery %) was 100 ± 0. 13. The limits of detection and quantitation are 0.18 and 0.54 µg .ml-1, respectively. The method was successfully applied to the determination of tadalafil in some pharmaceutical formulations
... Show MoreTwo simple, sensitive, accurate and economic methods A and B have been developed for the quantitative estimation of vancomycin hydrochlorid (VHC) and its formulations using another two drug compounds as a coupling reagents.The proposed methods are based on a coupling reaction between VHC and diazotized procain (method A) or diazotized sulphacetamide sodium (method B) in alkaline medium to form intense yellow, water-soluble dyes that are very stable and have a maximum absorption at 447 and 439 nm for methods A and B respectively. Regression analysis of Beer’s law plots showed good correlation in the concentration ranges 1-28 and 1-45 μg ml-1 for methods A and B, respectively with a molar absorbtivity of 4.605×104 L mol-1cm-1 and 4.516
... Show MoreIn this article, the existence of thermal radiation with Copper- water nanofluid, the effect of heat transfer in unsteady magnetohydrodynamics (MHD) squeezing and suction-injection on the flow between parallel plates( porous medium) are studied. Rosseland approximation and the radiation of heat flux are used to depict the energy equation. The set of ordinary differential equations with boundary conditions are analytically resolved by applying a new approach method (NAM). The influences of thermal field and physical parameters on dimensionless flow field have been displayed in tabular and graphs form. The presented results show that the heat transfer coefficient is reduced by the thermal radiation coefficient in
... Show More