A new, simple, accurate, fast and sensitive spectrophotometric method has been developed for the analysis of amiloride in pure and pharmaceutical formulations by continuous flow injection analysis. The method was based on the oxidation of the drug with Ce(IV)sulfate in acidic medium to formed a pinkish-red color species which determined using homemade Ayah 3SBGR x3-3D solar cell flow injection photometer. Optimum conditions were obtained using a high intensity green light emitted diode as a source. The linear dynamic range for the instrument response versus amiloride concentration was 0.0005- 10 mmol.L-1 while the L.O.D was of 9.471 ng / sample. The correlation coefficient (r) was 0.9824 while percentage linearity (r2%) was 96.50%. RSD% for the repeatability (n=8) was lower than 1.5% for the determination of amiloride, at concentration of 0.5 mmol.L-1. The method was applied successfully for the determination of amiloride in pharmaceutical preparation. A comparison was made between the newly developed method and the classical method (UV-Vis spectrophotometry at wave length 540nm) of analysis using the standard additions method via the use of paired t-test. It showed that there was no significant difference between the quoted value of each individual company with calculated t-value at 95% confidence interval from developed method, in addition to comparison between two methods and calculate t-value, it was noticed that there no significant difference between two methods at 99% but a significant difference at 95% confidence level.
A new simple sensitive and selective spectrophotometric method has been developed for the analysis of vanadium(V) in three randomly chosen samples from river water at different locations by continuous flow injection analysis. The method based on the oxidation of pyrogallol by vanadium(V) in acidic solution to form color species and the same species was determined using homemade Ayah 6SX1-T-2D solar cell analyser . Chemical and physical parameters were investigated using the high intensity of snow white light emitted diode as a source. The linear dynamic range for the instrument response versus vanadium(V) concentration was 1-200 mg.L-1 with correlation coefficient r = 0.9920. The limit of detection (S/N=3) was 70 ng/ sample from the step
... Show MoreA newly developed analytical method characterized by its speed and sensitivity for the determination of mefenamic acid (MFA) in pure and pharmaceutical preparation is established via turbidimetric measurement (0-180o) by Ayah 6SX1-ST-2D Solar cell CFI Analyser . The method was based on the reaction of
phosphomolybdic acid with mefenamic acid in aqueous medium to form blue color precipitate as an ion-pair complex . Turbidity was measured via the reflection of incident light that collides on the surface precipitated particles at 0-180o . The chemical and physical parameters were studied and optimized. The calibration graph was linear in the range of 0.3-7 or 0.3-10 mMol.L-1, with correlation coefficient r = 0.9907 or 0.9556 respectively
A new Turbidimetric method characterized by simplicity, accuracy and speed for determination of Hydronium ion by continuous flow injection analysis. The method was based on the formation of complex Zn3[Fe(CN)6] for Zinc(II) that was eluted by Hydronium ion from cation exchanger column with Potassium hexacyanoferrate(III) for the formation of a pale yellow precipitate and this precipitate was determined using homemade Linear Array Ayah-5SX1-T-1D continuous flow injection analyser. The optimum parameters were 2.7 mL.min-1 flow rate using H2O as a carrier stream, 1.7 mL.min-1 reagent stream, 110 L sample volume and open valve for the purge of the sample segment. Data treatment shows that linear range 0.01-0.1 mol.L-1 for each acids (HClO
... Show MoreA new Turbidimetric method characterized by simplicity, accuracy and speed for determination of Hydronium ion by continuous flow injection analysis. The method was based on the formation of complex Zn3[Fe(CN)6] for Zinc(II) that was eluted by Hydronium ion from cation exchanger column with Potassium hexacyanoferrate(III) for the formation of a pale yellow precipitate and this precipitate was determined using homemade Linear Array Ayah-5SX1-T-1D continuous flow injection analyser. The optimum parameters were 2.7 mL.min-1 flow rate using H2O as a carrier stream, 1.7 mL.min-1 reagent stream, 110 L sample volume and open valve for the purge of the sample segment. Data treatment shows that linear range 0.01-0.1 mol.L-1 for each acids (HClO
... Show MoreStrong acids were determined via the precipitation reaction of loaded copper (II) ion on strong cation exchange resin which in turn reacts with potassium hyxacyano ferrate (II). The attenuation effect of formed precipitate Cu2 [Fe (CN) 6] on (0 -180o) incident LED light was measurement via homemade AYAH 5SX4-ST-5D solar CFI analyser. Optimum parameters were 0.005M.L-1 [Fe(CN)6]-4 , flow rate of 2.4 mL.min-1 , sample volume 204 μL , sample purge time of 64 seconds was chosen, and 1.6 V for light intensity. A liner calibration graph of 0.005 -0.2 M.L-1 were obtains for HCl, HNO3, HCLO4 and H2SO4, with a linearity (r2 %) 96 -97 % and L.O.D based on gradual dilution of lowest concentration in calibration graph was 37.19 μg for HCl, 64.273
... Show MoreA new mode of methodology was adopted in the assay of PM- HCL based on the use of water crystal gel bead made of poly acrylic acid in which the gel beads were left to absorbe persulphate solution that is necessary for the oxidation of PM- HCL in aqua media . The water crystal act as a reserviour for S2O82- . Optimum parameters were studied giving to specify the chemical and physical parameters. Two line manifold was used .The flow rates of 1.5 and 1.2 ml.min-1 was used , 3 gel beads , 120 μL sample volume , a linear dynamic range extend from 0.01- 18 mmol.L-1. A correlation coefficient (r) of 0.9991while the percentage linearity (r2%) of 99.82% with R.S.D% at 8 mmol.L-1 promethazine-HCl is less than 0.5% (ten replicates) and a detection
... Show MoreA new turbidimetric-flow injection method is described for the determination of chlorpromazine HCl in pure and pharmaceutical preparation. The method is characterized by simplicity, sensitivity and fast, it is based on formation of ion pair compound between chlorpromazine HCl and Potassium hexacyanoferrate(III) in an acid medium for the formation of greenish yellow precipitate. This precipitate was determined using homemade Linear Array Ayah 5SX1-T-1D continuous flow injection analyser. Optimum concentrations of chemical reactants, physical instrumental conditions have been investigated. The linear dynamic range of chlorpromazine HCl was 3-30 mmol.L-1 while correlation coefficient (r) was 0.9929 and percentage linearity (%r2) C.O.D was 9
... Show MoreA sensitivity-turbidimetric method at (0-180o) was used for detn. of mebeverine in drugs by two solar cell and six source with C.F.I.A.. The method was based on the formation of ion pair for the pinkish banana color precipitate by the reaction of Mebeverine hydrochloride with Phosphotungstic acid. Turbidity was measured via the reflection of incident light that collides on the surface particles of precipitated at 0-180o. All variables were optimized. The linearity ranged of Mebeverine hydrochloride was 0.05-12.5mmol.L-1, the L.D. (S/N= 3)(3SB) was 521.92 ng/sample depending on dilution for the minimum concentration , with correlation coefficient r = 0.9966while was R.S.D%
... Show More