This study was conducted to evaluate the effect of discharge of water purification plants ,on the purity of Tigris River water in Baghdad city. The two studied plants were involved in the study : Sharq –Dijla and Al-Karama water purification plants. The study was attempted to focus on probable pollutants. Chemical, physical tests were accomplished on water samples collected from four sites with fact of three replicates for each sample of each site of the river and the plant : before, after, inside the plants and at the pipe. This study started from October 2012 to September 2013. In case of heavy metals Results showed that the highest level of aluminum was 1.08 ppm during (December-January) at Sharq-Dijla plants, while the lowest level was 0.059 ppm during (August- September) at AL- Karama plants ,while results of iron which recorded the highest level 3.30 ppm during (December-January) at Sharq –Dijla plants, while the lowest level was 1.63 ppm during (August- September) at Sharq –Dijla plants. It was found that the highest level of turbidity was 119 N.T.U during (December-January) at Sharq- Dijla plants, while the lowest level was 33.0 N.T.U during ( June-July) at Sharq-Dijla plants. While the highest level of EC was 1068 μS/cm during (December-January) at Sharq-Dijla plants, while the lowest level was 693 μS/cm during ( June-July) at Sharq-Dijla plants .T.D.S recorded highest level during (December-January) at AL- Karama plants which was 687 ppm , while the lowest recorded level was 506 ppm during ( August- September) at Sharq-Dijla plants, also the highest level of T.S.S was 793 ppm during (December-January) at AL- Karama plants, while the lowest level was 410 ppm during ( August- September) at Sharq-Dijla plants .
Sixteen water samples were collected from the operation units of the Al-Quds
power plant, north Baghdad city and the surrounding trocars, surface and
groundwater, and analyzed to assess the resulting pollution. The samples were
analyzed for heavy metals (As, Cd, Cr, Cu, Mn, Mo, Ni, Pb, Sb, Se, U and Zn) by
using inductively coupled plasma- mass spectrometry (ICP-MS). The results were
compared with local and international and standard limits. Heavy metals analysis of
the water samples shows that water of operation units and trocars have mean
concentrations of As, Cd, Cr, Cu, Mo, Pb, Sb, Se, U and Zn were within or lower
than the national and world limits, while Mn and Ni were higher than these limits.
Concentrat
Phosphorus is usually the limiting nutrient for eutrophication in inland receiving waters; therefore, phosphorus concentrations must be controlled. In the present study, a series of jar test was conducted to evaluate the optimum pH, dosage and performance parameters for coagulants alum and calcium chloride. Phosphorus removal by alum was found to be highly pH dependent with an optimum pH of 5.7-6. At this pH an alum dosage of 80 mg/l removed 83 % of the total phosphorus. Better removal was achieved when the solution was buffered at pH = 6. Phosphorus removal was not affected by varying the slow mixing period; this is due to the fact that the reaction is relatively fast.
The dosage of calcium chloride and pH of solution play an importa
The study aims to assess some physical, chemical, and bacterial characteristics of two drinking water treatment plants of Al- Dora and Al-Qadisiya in the area of ​​Karkh, Baghdad, Iraq. The areas covered by each plants and these sites of areas selected as the nearest and the farthest point from plants, for winter and summer season. Some physicochemical parameters of water quality were taken in this study and these parameters were temperature water, pH, electrical conductivity, total dissolved solids, free residual chlorine, calcium, magnesium, nitrate, nitrite, sulphate and heavy metals (lead). In addition to four bacterial indicators of drinking water pollution (APC, Total Coliform, Fecal Coliform
... Show Morewater quality assessment is still being done at specific locations of major concern. The use of Geographical Information System (GIS) based water quality information system and spatial analysis with Inverse Distance Weighted interpolation enabled the mapping of water quality indicators along Tigris river in Salah Al-Din government, Iraq. Water quality indicators were monitored by taking 13 river samples from different locations along the river during Winter season year 2020. Maps of 10 water quality indicators. This meant that the specific water quality indicator and diffuse pollution characteristics in the basin were better illustrated with the variations displayed along the course of the river than conventional line graphs. Creation of
... Show MoreThe quality of industrial water from (Babil / 2 batteries factory in Baghdad) was investigated, and evaluated the physical and chemical characteristics of the water discharged from sections ALShahen , final collection sank. The values were represented by pH, electrical conductivity, biological oxygen demand, chemical oxygen demand ,total suspended solid, total dissolved solid, sulfate, chloride and heavy metal. The sample of water collocated by two samples per month for 6 months was taking during the period from Novembers 2013 to May 2014. The results show that industrial waste water factory contains contaminations and has varying value rates the average of PH,EC, TDS, SO4, COD, Pb, Zn, for the final c
... Show MoreWater treatment plants play an important role in the purification and distribution of safe drinking water to the public. The present study focused on the performance assessment of the Al-Rasheed water treatment plant [ARWTP]. The main objectives of the assessment were to determine the efficiency of various plant units as well as the quality of inlet water from the Tigris River. Results obtained from the collected data indicated the presence of high concentrations of soluble nitrate and phosphate ions in the filtered water. The removal efficiency of alkalinity, EC, total hardness, SO4, Cl, NO3 and PO4 were found to be (+11.05%), (-0.67%), (-29.33%), (-2.64%), (-6.25%), (-32.13%), and (0%) respecti
... Show MoreThis research consists of two parts, the first part concern with analyzing the collected data of BOD and COD values in discharge waste water from Al-Dora refinery during 2010 to find the relationship between these two variables The results indicates that there is a high correlation between BOD and COD when using a natural logarithm model (0.86 ln(COD)) with correlation coefficient of 0.98. This relationship is useful in predicting the BOD value using the COD value. The second part includes analyzing collected data from the same site in order to find a relationsip between BOD and other parameters COD, Phenol(phe), Temperature(T), Oil, Sulphat(SO4),pH and Total dissolved solids( TDS) discharged from the refinery. The results indicated that th
... Show MoreThis research consists of two parts, the first part concern with analyzing the collected data of BOD and COD values in discharge waste water from Al-Dora refinery during 2010 to find the relationship between these two variables The results indicates that there
is a high correlation between BOD and COD when using a natural logarithm model (0.86 ln(COD)) with correlation coefficient of 0.98. This relationship is useful in predicting the BOD value using the COD value. The second part includes analyzing collected data from the same site in order to find a relationsip between BOD and other parameters COD, Phenol(phe), Temperature(T), Oil, Sulphat(SO4),pH and Total dissolved solids( TDS) discharged from the refinery. The results indicated
This paper aims to evaluate large-scale water treatment plants’ performance and demonstrate that it can produce high-level effluent water. Raw water and treated water parameters of a large monitoring databank from 2016 to 2019, from eight water treatment plants located at different parts in Baghdad city, were analyzed using nonparametric and multivariate statistical tools such as principal component analysis (PCA) and hierarchical cluster analysis (HCA). The plants are Al-Karkh, Sharq-Dijlah, Al-Wathba, Al-Qadisiya Al-Karama, Al-Dora, Al-Rasheed, Al-Wehda. PCA extracted six factors as the most significant water quality parameters that can be used to evaluate the variation in drinkin
Abstract
This Research aims for harnessing critical and innovative thinking approaches besides innovative problem solving tools in pursuing continual quality improvement initiatives for the benefit of achieving operations results effectively in water treatment plants in Baghdad Water Authority. Case study has been used in fulfilling this research in the sadr city water treatment plant, which was chosen as a study sample as it facilitates describing and analyzing its current operational situation, collecting and analyzing its own data, in order to get its own desired improvement opportunity be done. Many statistical means and visual thinking promoting methods has been used to fulfill research task.
... Show More