Preferred Language
Articles
/
ijs-11282
New Mode for the On-Line Determination of Amiloride in Pure and Pharmaceutical Preparation Using CFIA Via the Use of Linear Array from Six LED (Snow White) with One Solar Cell in a Homemade Ayah 6Sx1-T-1D Solar CFI Analyser
...Show More Authors

A newly flow injection-turbidimetric method characterized by it is speed and sensitivity has been developed for the determination of Amiloride in pure and pharmaceutical preparations. It is based on the formation of yellowish white precipitate for the Amiloride-phosphomolybidic acid ion pair in aqueous medium. Turbidity was measured by Ayah 6Sx1-T-1D solar cell CFI analyser via the attenuation of incident light from the surfaces precipitated particles at 0-180. The Chemical and physical parameters were investigated. Linear dynamic range for the attenuation of incident light versus Amiloride concentration was of 0.005-10 mmol.L-1, with the correlation coefficient (r) of 0.9986 , while the percentage linearity (r2%) was 99.71%. The L.O.Q was of 23.14 μg/sample, while L.O.D (S/N=3) =5.74 ng/sample from the stepwise dilution for the minimum concentration in the calibration graph. The R.S.D% at 3, 9 mmol.L-1 Amiloride is less than 0.5% (eight replicates) using 50 μL sample volume. Through put was of 40 sample.hr-1. The method was applied successfully for the determination of Amiloride in pharmaceutical preparations. A comparison was made using the standard additions method via the use paired t-test. It showed that there was no significant difference between the quoted value of each individual paired t-test with calculated t-value at 95% confidence interval from developed method. In addition to comparison between two methods and calculate t-value, it was noticed that there was no significant difference between the two methods at =0.05 (95% confidence level).

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Oct 22 2023
Journal Name
Iraqi Journal Of Science
New Approach for an On-Line Turbidimetric Determination of Cadmium (II) in Different River Water Via the Use of A homemade Ayah 6SX1-T-2D Solar-Continuous Flow Injection Analyser
...Show More Authors

A newly developed analytical method characterized by its speed and sensitivity for
the determination of cadmium (II) in aqueous solution in three randomly chosen
samples from river water at different locations via turbidimetric measurement by
Ayah 6SX1-T-2D Solar - CFI analyser. The method is based on the formation of
yellowish white precipitate for the complex Cd3[Fe(CN)6]2 by direct reaction of the
cadmium (II) with potassium hexacyano ferrate (III) in aqueous medium. Turbidity
was measured via the reflection of incident light that collides on the surfaces
precipitated particles at 0-180o. Chemical and physical parameters were investigated.
Linear dynamic of cadmium (II) is ranged from 0.05-12 mmol.L-1, with cor

... Show More
View Publication Preview PDF
Publication Date
Sun Oct 22 2023
Journal Name
Iraqi Journal Of Science
New Approach for The Turbidimetric Determination of Iron(III) in Drug Samples of Different Origins Using Homemade Linear Array Ayah 5SX1-T-1D-CFI Analyser
...Show More Authors

A new Turbidimetric method characterized by simplicity, accuracy and speed for determination of iron(III) in drug samples by continuous flow injection analysis. The method was based on the formation of complex for iron(III) with 8-hydroxyquinoline in presence of ammonium acetate as a medium for the formation of deep green precipitate and this precipitate was determined using homemade Linear Array Ayah-5SX1-T-1D continuous flow injection analyser. The optimum parameters were 2.6 mL.min-1 flow rate using H2O as a carrier, 1.9 mL.min-1 (14 mmol.L-1) ammonium acetate, 2.4 mL.min-1 (14 mmol.L-1) 8-hydroxyquinoline, 60 L sample volume and open valve for the purge of the sample segment. Data treatment shows that linear range 0.1-8.0 mmol.L-1

... Show More
View Publication Preview PDF
Publication Date
Sun Apr 30 2023
Journal Name
Iraqi Journal Of Science
A new mode for an on-line determination of Pyrocatechol, Resorcinol, and Pyrogallol in pure commercial samples using CFIA with homemade Ayah 3SBGRx3- 3D solar cell microphtometer analyzer.
...Show More Authors

A new, simple, accurate, fast and sensitive spectrophotometric method has been
developed for the analysis of Pyrocatechol, Resorcinol, and pyrogallolin pure
commercial samples by continuous flow injection analysis. The method was based on
the oxidation of the organic compounds with Ce(IV)sulfate in acidic medium to
formed a brown colored species which determined using homemade Ayah 3SBGR x3-
3D solar cell flow injection microphotometer. Optimum conditions were obtained
using a high intensity green light emitted diode as an irradiation source
forPyrocatechol, Resorcinol, whileblue light emitted diode as an irradiation source for
pyrogallol. The linear dynamic range for the instrument response versus Pyrocatechol,

... Show More
View Publication Preview PDF
Publication Date
Tue Jan 01 2019
Journal Name
Research Journal Of Pharmacy And Technology
New Mode Semi-Automated Turbidimetric Determination of Mefenamic Acid by Ayah 6SX1-ST-2D Solar cell-CFI Analyser
...Show More Authors

View Publication
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Fri Nov 24 2023
Journal Name
Iraqi Journal Of Science
New Approach for the On-Line Spectrophotometric Determination of Folic Acid in Pure and Pharmaceutical Preparation via Oxidation by Cerium(IV) Sulphate Using Ayah 3Sx3-3D-Solar Cell CFI Spectrophotometer Analyzer
...Show More Authors

A newly photometric analytical method characterized by its speed and sensitivity was developed for the determination of folic acid in pure and pharmaceutical samples via its oxidation to reddish-orange coloured complex through oxidation by cerium (IV) sulphate in aqua medium using homemade Ayah 3Sx3-3D-solar cell CFI photometer. The colored species were determined using supper bright green light emitting diode (LED) as a source. A 100μl was taken as a best sample volume for the determination of folic acid. The linearity of calibration curve for the instrument response versus folic acid concentration was 0.005-20 mmol.L-1 while the L.O.D. was 0.5  mol.L-1 from the stepwise dilution for the minimum concentration of lowest concentration

... Show More
View Publication Preview PDF
Publication Date
Sun Oct 22 2023
Journal Name
Iraqi Journal Of Science
New Developed Data Treatments for the Characteristic Linear Array Ayah 5SX1-T-1D-CFI Analyser Segment Response Profile & Generalization
...Show More Authors

Derivative spectrophotometry is one of the analytical chemistry techniques used
in the analysis and determination of chemicals and pharmaceuticals. This method is
characterized by simplicity, sensitivity and speed. Derivative of Spectra conducted
in several ways, including optical, electronic and mathematical. This operation
usually be done within spectrophotometer. The paper is based on form of a new
program. The program construction is written in Visual Basic language within
Microsoft Excel. The program is able to transform the first, second, third and fourth
derivatives of data and the return of these derivatives to zero order (normal plot).
The program was applied on experimental (trial) and reals values of su

... Show More
View Publication Preview PDF
Publication Date
Sun Oct 22 2023
Journal Name
Iraqi Journal Of Science
A Novel Semi Automated On-Line Determination of Oxonium Ion Via Precipitation Reaction Using a New Mode of Attenuated Measurement of Incident Light (0 – 180o) by AYAH 5SX4-ST-5D Solar CFI Analyser.
...Show More Authors

Strong acids were determined via the precipitation reaction of loaded copper (II) ion on strong cation exchange resin which in turn reacts with potassium hyxacyano ferrate (II). The attenuation effect of formed precipitate Cu2 [Fe (CN) 6] on (0 -180o) incident LED light was measurement via homemade AYAH 5SX4-ST-5D solar CFI analyser. Optimum parameters were 0.005M.L-1 [Fe(CN)6]-4 , flow rate of 2.4 mL.min-1 , sample volume 204 μL , sample purge time of 64 seconds was chosen, and 1.6 V for light intensity. A liner calibration graph of 0.005 -0.2 M.L-1 were obtains for HCl, HNO3, HCLO4 and H2SO4, with a linearity (r2 %) 96 -97 % and L.O.D based on gradual dilution of lowest concentration in calibration graph was 37.19 μg for HCl, 64.273

... Show More
View Publication Preview PDF
Publication Date
Fri Jun 24 2022
Journal Name
Iraqi Journal Of Science
Determination of Mefenamic Acid Using a New Mode of Irradiation (Array of Six Identical LEDs) and Detection( Twin Solar Cells) Through Turbidity Measurement by CFIA
...Show More Authors

A newly developed analytical method characterized by its speed and sensitivity for the determination of mefenamic acid (MFA) in pure and pharmaceutical preparation is established via turbidimetric measurement (0-180o) by Ayah 6SX1-ST-2D Solar cell CFI Analyser . The method was based on the reaction of
phosphomolybdic acid with mefenamic acid in aqueous medium to form blue color precipitate as an ion-pair complex . Turbidity was measured via the reflection of incident light that collides on the surface precipitated particles at 0-180o . The chemical and physical parameters were studied and optimized. The calibration graph was linear in the range of 0.3-7 or 0.3-10 mMol.L-1, with correlation coefficient r = 0.9907 or 0.9556 respectively

... Show More
View Publication Preview PDF
Publication Date
Wed Sep 01 2021
Journal Name
Baghdad Science Journal
New Method for Estimation Mebeverine Hydrochloride Drugs Preparation by a New Analyser: Ayah 6S.X1(WSLEDs)-T.- Two Solar Cells Complied with C.F.I.A
...Show More Authors

A sensitivity-turbidimetric method at (0-180o) was used for detn. of mebeverine in drugs by two solar cell and six source  with C.F.I.A.. The method was based on the formation  of  ion pair for the pinkish banana color  precipitate by the reaction of Mebeverine hydrochloride with Phosphotungstic acid. Turbidity was measured via the reflection of incident light that collides on the surface particles of   precipitated at 0-180o. All variables were optimized. The linearity ranged of Mebeverine hydrochloride was 0.05-12.5mmol.L-1, the L.D. (S/N= 3)(3SB) was 521.92 ng/sample depending on dilution for the minimum concentration , with correlation coefficient r = 0.9966while was R.S.D%

... Show More
View Publication Preview PDF
Scopus (5)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Sun Dec 01 2013
Journal Name
Baghdad Science Journal
Flow injection analysis for the photometric determination of promethazine-HCl in pure and pharmaceutical preparation via oxidation by persulphate using Ayah 3SX3-3D solar micro photometer
...Show More Authors

The first flow injection spectrophotometric method is characterized by its speed and sensitivity which have been developed for the determination of promethazine-HCl in pure and pharmaceutical preparation. It is based on the in situ detection of colored cationic radicals formed via oxidation of the drug with sodium persulphate to pinkish-red species and the same species was determined by using homemade Ayah 3SX3-3D solar flow injection photometer. Optimum conditions were obtained by using the high intensive green light emitted diode as a source. Linear dynamic range for the absorbance versus promethazine-HCl concentration was 0-7 mmol.L-1, with the correlation coefficient (r) was 0.9904 while the percentage linearity (r2%) was 98.09%. the L.

... Show More
View Publication Preview PDF
Crossref