Preferred Language
Articles
/
ijs-10426
Computer Generation of Low Light-Level Images
...Show More Authors

As result of exposure in low light-level are images with only a small number of
photons. Only the pixels in which arrive the photopulse have an intensity value
different from zero. This paper presents an easy and fast procedure for simulating
low light-level images by taking a standard well illuminated image as a reference.
The images so obtained are composed by a few illuminated pixels on a dark
background. When the number of illuminated pixels is less than 0.01% of the total
pixels number it is difficult to identify the original object.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Mar 30 2022
Journal Name
Iraqi Journal Of Science
Photodynamic Inactivation (Effect of Laser with and Without Photosensitizer) on Viability of Streptococcus Pyogenes
...Show More Authors

     This study focused on the bactericidal potency of toluidine blue” TBO”photosensitizer and red laser radiation of 635nmwith different doses against multi-drug resistant streptococcus pyogenes (S. pyogenes) isolated from infected burns wounds to see if it is susceptible to photodynamic inactivation .

Atotal of 45 isolates were collected from 38” patients” with infected burnwounds samples were collected from September to December 2019.Burns wounds swabs were employed using standard procedures of swab collection. Among these, eleven isolates were multidrug resistant”S.pyogenes”. More resistant isolates that has been proved to all antibiotics used. This multidrug resistant isolate used in

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Fri Jun 24 2022
Journal Name
Iraqi Journal Of Science
Compression of Astronomical Image Using Five Modulus Method
...Show More Authors

The computer vision branch of the artificial intelligence field is concerned with
developing algorithms for analyzing image content. Data may be compressed by
reducing the redundancy in the original data, but this makes the data have more
errors. In this paper image compression based on a new method that has been
created for image compression which is called Five Modulus Method (FMM). The
new method consists of converting each pixel value in an (4x4, 8×8,16x16) block
into a multiple of 5 for each of the R, G and B arrays. After that, the new values
could be divided by 5 to get new values which are 6-bit length for each pixel and it
is less in storage space than the original value which is 8-bits.

View Publication Preview PDF
Publication Date
Thu May 04 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Linear Prediction of Sum of Two Poisson Process
...Show More Authors

Our goal from this work is to find the linear prediction of the sum of two Poisson process
) ( ) ( ) ( t Y t X t Z + = at the future time 0 ), ( ≥ + τ τ t Z and that is when we know the values of
) (t Z in the past time and the correlation function ) (τ βz

View Publication Preview PDF
Publication Date
Wed May 17 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
The Study Effect of Lighting of Non – Regular on Statistical Properties for the Written Text on Whiteboard
...Show More Authors

 Lighting is a very important element of treatment if the color contains many imaging system (digital cameras) and the unit of light and the light within these units are not strong , but usefel when the light is low , in different lighting intensities conditions image quality will not persist good enough and image may become dark or slightly exposed to light which leads to lower the details in image where we can not modify contrast or light ness to compensate thr decrease without losing the light and dark deatials . So we went in this research to study the variation colored texts written on the painting and lighting cases of non –regular ( a few) and different distances . As the diversity of these texts written on the board a

... Show More
View Publication Preview PDF
Publication Date
Wed Dec 18 2019
Journal Name
Baghdad Science Journal
Effect of Refractive Index on Photon Natural Mass and Wavelength
...Show More Authors

In this article it is proved experimentally that the photon is a particle that has mass and constant wavelength by explaining the effect of refractive index on the wavelength and the natural mass of photon. It is very difficult to measure the mass of photon, a simple and easy process was proposed in this paper to calculate the mass length of photon in vacuum (Y) and in medium (Y*), by measuring the length of laser beam in air (Lair) and in medium (Lmed). A new method was postulated to calculate refractive index by using these relations (n = Y*/Y), and (n = Lmed / Lair) which supposed a new theory of light.

View Publication Preview PDF
Scopus Clarivate Crossref
Publication Date
Thu Jan 20 2022
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Posterior Estimates for the Parameter of the Poisson Distribution by Using Two Different Loss Functions
...Show More Authors

In this paper, Bayes estimators of Poisson distribution have been derived by using two loss functions: the squared error loss function and the proposed exponential loss function in this study, based on different priors classified as the two different informative prior distributions represented by erlang and inverse levy prior distributions and non-informative prior for the shape parameter of Poisson distribution. The maximum likelihood estimator (MLE) of the Poisson distribution has also been derived. A simulation study has been fulfilled to compare the accuracy of the Bayes estimates with the corresponding maximum likelihood estimate (MLE) of the Poisson distribution based on the root mean squared error (RMSE) for different cases of the

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Oct 01 2021
Journal Name
International Journal Of Electrical And Computer Engineering (ijece)
Design and implementation of silicon single-photon avalanche photodiode modeling tool for QKD systems
...Show More Authors

Single-photon detection concept is the most crucial factor that determines the performance of quantum key distribution (QKD) systems. In this paper, a simulator with time domain visualizers and configurable parameters using continuous time simulation approach is presented for modeling and investigating the performance of single-photon detectors operating in Gieger mode at the wavelength of 830 nm. The widely used C30921S silicon avalanche photodiode was modeled in terms of avalanche pulse, the effect of experiment conditions such as excess voltage, temperature and average photon number on the photon detection efficiency, dark count rate and afterpulse probability. This work shows a general repeatable modeling process for significant perform

... Show More
View Publication
Scopus Crossref
Publication Date
Fri Dec 15 2023
Journal Name
Iraqi Journal Of Laser
The Effect of Dual Diode Laser: (810,980) nm in Acceleration of Orthodontic Tooth Movement A Case Report
...Show More Authors

Patients are very concerned about the lengthy nature of orthodontic treatment. It is necessary to find a non-invasive way to quicken physiologic tooth movement. This study's objective was to assess the effectiveness of low-intensity laser therapy in shortening the time and discomfort of orthodontic treatment. Experimental work: Using a split-mouth study to compare tooth movement with conventional treatment and laser-accelerated orthodontic tooth movement. A patient presenting with a class II division I malocclusion characterized by the misalignment of the upper and lower teeth as classified by Angle’s molar classification system was indicated to undergo fixed orthodontic appliance orthodontic treatment. The treatment plan involved bila

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Feb 02 2025
Journal Name
Baghdad Science Journal
Study the effect of position on the time of astronomical twilight
...Show More Authors

Twilight is that light appear on the horizon before sunrise and after sunset, Astronomically it is known that sunrise and sunset are effected by high above sea level, but the effect of high above sea level on the time of astronomical twilight still not decided and controversy among astronomers, in This research we studies the effect of high above sea level on the time of astronomical twilight, through adding the equation correct high above sea level to equation computation of twilight and then calculate of changing in the time of twilight for different highest (0-10000) meters above sea level , and the ratio of increase for time with high between (15.45-20.5) minutes. It was found that there was an increase in the time of the twilight along

... Show More
View Publication
Publication Date
Fri Jun 20 2014
Journal Name
Jurnal Teknologi
A Review of Snake Models in Medical MR Image Segmentation
...Show More Authors

Developing an efficient algorithm for automated Magnetic Resonance Imaging (MRI) segmentation to characterize tumor abnormalities in an accurate and reproducible manner is ever demanding. This paper presents an overview of the recent development and challenges of the energy minimizing active contour segmentation model called snake for the MRI. This model is successfully used in contour detection for object recognition, computer vision and graphics as well as biomedical image processing including X-ray, MRI and Ultrasound images. Snakes being deformable well-defined curves in the image domain can move under the influence of internal forces and external forces are subsequently derived from the image data. We underscore a critical appraisal

... Show More
Scopus (10)
Scopus