This paper is carried out to detect the subsurface structures that have geological
and economical importance by interpreting the available reflection seismic data of
an area estimated to be about (740) km2. The Khashim Al-Ahmer structure is partial
of series structures of (Injana – Khashim Al-Ahmer – Mannsorya) from the (NW to
the SE), it is located within for deep faulted area. The component of the one
elongated dome of asymmetrical of structure which has(SW) limb more steeper than
the (NE) limb.Twenty three seismic sections had been interpreted for two seismic
surveys and the total length of all seismic lines is about (414.7) Km. Interpretation
of seismic data was focused on two reflectors (Fatha and Jeribi) Formations which
belong to Lower and Middle Miocene age. The reflectors were picked and identified
by tying them directly to well Khashim Al-Ahmer-2, the Lower Fars(Fatha
Formation) reflector was picked at TWT ranging from (0.3-1.7) sec while the Jeribi
reflector was picked at TWT ranging from (0.83- 2) sec. The depth map showed that
the depth of the Jeribi Formation ranges between (1100 - 2000) m, and the velocity
maps of studied reflector showed increase of velocity values to the south east and
there is a local closure in the north east of the study area and decrease to the north
west and the velocity values decrease and give closure situated below well KA-
2.The magnitude of velocity values ranges in Jeribi velocity map from (3100 to 3400
m/sec). Seismic attributes techniques (instantaneous phase) is important to detect the
hydrocarbon accumulation on seismic sections. Major faults (reverse and thrust)
were picked along study area on instantaneous phase sections. These faults extend in
NW-SE trend and the displacement of the fault ranges between (400-660) m. The
velocity, time and depth maps were drawn by the aid of GeoFrame and petrel
software.
In this study, the surface of the epoxy/Al composite is treated using a dielectric barrier discharge (DBD) plasma in the presence of air. The epoxy composite was prepared by mixing 0.1g and 0.3 g aluminum powder with epoxy resin and its hardener in a ratio of 3:1. The surface epoxy/Al composite as a dielectric barrier layer (DB) is studied at an applied frequency of 8 kHz and at three exposure times 0, 2, and 4 min. The UV degradation process has been studied using UV-Visible spectroscopy, for these polymers. The absorbance intensity in the UV region (200–320 nm) was high. The absorbance level decreased after 2 minutes and increased after 4 min exposure time. Before exposure to plasma, the epoxy/Al composite at 0.1 g Al ha
... Show MoreSpatial data analysis is performed in order to remove the skewness, a measure of the asymmetry of the probablitiy distribution. It also improve the normality, a key concept of statistics from the concept of normal distribution “bell shape”, of the properties like improving the normality porosity, permeability and saturation which can be are visualized by using histograms. Three steps of spatial analysis are involved here; exploratory data analysis, variogram analysis and finally distributing the properties by using geostatistical algorithms for the properties. Mishrif Formation (unit MB1) in Nasiriya Oil Field was chosen to analyze and model the data for the first eight wells. The field is an anticline structure with northwest- south
... Show MoreIn this study; a three-dimensional model was created to simulate groundwater in Al-Haydariyah area of the governorate of Al-Najaf. A solid model was created to utilize the cross sections of 25 boreholes in the research region, and it was made out of two layers: sand and clay. The steady-state calibration was employed in six observation wells to calibrate the model and establish the hydraulic conductivity, which was 17.49 m/d for sand and 1.042 m/d for clay, with a recharge rate of 0.00007 m/day. The wells in the research region were reallocated with a distance of 1500 m between each well, resulting in 140 wells evenly distributed throughout the study area and with a discharge of 5 l/s, and the scenarios were run for 1000
... Show MoreThe present study deals with processing of one seismic line (2WL2) with a length of (37km) for (2D) seismic data of west Luhais area that is located within the administrative borders of the province of Muthanna in south of Iraq. The quality of the recorded data of this line is in general weak due to the effect of noise mainly. The study was made up in oil Exploration Company by utilizing OMEGA software which consists of a great number of the processing programs. The elevation static correction and residual static correction were applied on the studied line and the final section were resulted after completing the treatment processes that proceed followed of the static correction process and the result of elevation static correcting was go
... Show MoreThis study focused on the soil of the Al-Khassa Sub Basin, thirty-four soil samples were collected from different areas of land use and differences in human activity.
Physicochemical properties of the soil were examined Hydrogen Potential (pH), Organic Matter (O.M), Loss Of Ignition (L.O.I), Total Organic Carbon (TOC), Cation Exchange Capacity (CEC) and Total Hydrocarbon (THC).
Hydrogen Potential (pH) showed that the soil is alkaline above seven with a mean 7.98.
Organic Matter (O.M) of the study area with a mean 1.28 % and high value found in Agricultural areas.Cation Exchange Capacity (CEC) with a mean 42.64 (cmol/kg) that is proportional to the granular size of the soil that silty c
... Show MoreA set of hydro treating experiments are carried out on vacuum gas oil in a trickle bed reactor to study the hydrodesulfurization and hydrodenitrogenation based on two model compounds, carbazole (non-basic nitrogen compound) and acridine (basic nitrogen compound), which are added at 0–200 ppm to the tested oil, and dibenzotiophene is used as a sulfur model compound at 3,000 ppm over commercial CoMo/ Al2O3 and prepared PtMo/Al2O3. The impregnation method is used to prepare (0.5% Pt) PtMo/Al2O3. The basic sites are found to be very small, and the two catalysts exhibit good metal support interaction. In the absence of nitrogen compounds over the tested catalysts in the trickle bed reactor at temperatures of 523 to 573 K, liquid hourly space v
... Show MoreThe present study aims to assess the water quality and the hydrochemical characteristics and seasonal variation of surface water on the aspect of trace elements in Al-Tarmiyah District, Baghdad, Iraq. Ten water samples were collected, four from surface water and six from groundwater on October 2017, and on April 2018. All samples were analyzed for physiochemical parameters such as water temperature, pH, EC, TDS,TH,TSS, major ions (Ca2+, Mg2+, Na+, K+, SO42-, Cl-, and HCO3-), and nutrients (NO3-, and PO43-). In addition, samples were analyzed for trace elements that include Fe, Al, Pb, Zn, Mn, Cr,
... Show MoreDatabase is characterized as an arrangement of data that is sorted out and disseminated in a way that allows the client to get to the data being put away in a simple and more helpful way. However, in the era of big-data the traditional methods of data analytics may not be able to manage and process the large amount of data. In order to develop an efficient way of handling big-data, this work studies the use of Map-Reduce technique to handle big-data distributed on the cloud. This approach was evaluated using Hadoop server and applied on EEG Big-data as a case study. The proposed approach showed clear enhancement for managing and processing the EEG Big-data with average of 50% reduction on response time. The obtained results provide EEG r
... Show MoreAmara oil field is located at south eastern Iraq in Missan governorate. The Mishrif Formation in Amara field is one of the most important reservoirs in southern Iraq. Identifying and characterizing petrophysical flow units are the key to understanding and improving reservoir description, exploitation, production and predicting the performance of carbonate reservoirs to represent them as combinations of different flow units, each with uniform pore throat size distribution and similar performance. Mishrif Formation in Amara oil field was divided into seven reservoir units (MA.MB11,MB12,MB13,MB21,MC1, and MC2) separated between them barrier beds. The present work is a reservoir flow unit identification for (MA) and (MB11) reservoir units of
... Show More