Preferred Language
Articles
/
ijp-869
Correlation of Paschen parameters in magnetized argon plasma
...Show More Authors

A number of glow discharge experiments has been carried out in a relatively large-volume metallic vacuum chamber containing argon at low pressure and immersed in an inhomogeneous magnetic field generated by a solenoidal coil capable of delivering 2100G. Two Paschen curves demonstrating the dependence of the discharge voltage on sparking parameter Pd and magnetic field strength B were deduced. A graphical correlation showing the behaviour of the voltage difference from the two curves on the ratio B/Pd was constructed. Investigations showed a reduction in the nominal impedance of the discharge device of nearly 20% when B reaches a value of 525G. Plasma confinement regions were found around the internal surface of the chamber at the entrance of the electrodes which may be attributed to pressure gradient by JxB effects as well as ExB drifts.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Jun 01 2021
Journal Name
International Journal Of Statistical
Evaluating the performance of introduced varieties of maize (Zea Mays L.) and estimating some genetic parameters
...Show More Authors

Scopus (13)
Scopus
Publication Date
Wed Aug 05 2020
Journal Name
Neuroquantology
The Influence of Some Important Parameters on the Performance Efficiency of the Compound Parabolic Solar Concentrator
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Mon Aug 01 2022
Journal Name
Biochemical And Cellular Archives
EVALUATION OF THE TOXICITY OF DELTAMETHRIN INSECTICIDE ON SOME HEMATOLOGICAL PARAMETERS AND OXIDATIVE STRESS ON MICE
...Show More Authors

Publication Date
Thu Mar 01 2012
Journal Name
Journal Of Economics And Administrative Sciences
Using Truncated Test for Finding the Parameters of Single Sampling Plan under Distribution of Log-Logistic
...Show More Authors

A group of acceptance sampling to testing the products was designed when the life time of an item follows a log-logistics distribution. The minimum number of groups (k) required for a given group size and acceptance number is determined when various values of Consumer’s Risk and test termination time are specified. All the results about these sampling plan and probability of acceptance were explained with tables.

View Publication Preview PDF
Crossref
Publication Date
Thu Jun 29 2023
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
The Effect of Variable Parameters on Carbon Residue of Iraqi Vacuum Gas Oil using Ultrasound Techniques
...Show More Authors

An ultrasonic treatment was applied to the vacuum gas oil at intervals of 5 to 30 minutes, at 70°C.  In this work, the improvement of the important properties of Iraqi vacuum gas oil, such as carbon residue, was studied with several parameter conditions that affect vacuum efficiency, such as sonication time (5, 10, 15, 20, 25, and 30) min, power amplitude (10–50%). After ultrasonic treatment, the carbon residue of vacuum gas oil was evaluated using a Conradson carbon residue meter (ASTM D189). The experiment revealed that the oil's carbon residue had decreased by 16%. As a consequence of the experiment It was discovered that ultrasonic treatment might reduce the carbon residual and density of oil samples being studied. It also notice

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Mon Jun 05 2023
Journal Name
Al-khwarizmi Engineering Journal
A Review of the Stereo lithography 3D Printing Process and the Effect of Parameters on Quality
...Show More Authors

Stereo lithography (SLA) three-dimensional (3D) printing process is a type of additive manufacturing techniques that uses digital models from computer-aided design to automatically produce customized 3D objects. Around 30 years, it has been widely utilized in the manufacturing, design, engineering, industrial sectors and its applications in dentistry for manufacturing prosthodontics are very important. The stereo lithography technology is highly regarded because it can produce items with excellent precision especially when selecting the best process parameters. This review article offers a useful and scientific summary of SLA three-dimensional printing technology and its brief history. The specific type of 3D printers which is SLA t

... Show More
Scopus (20)
Crossref (21)
Scopus Crossref
Publication Date
Mon Jun 05 2023
Journal Name
Al-khwarizmi Engineering Journal
A Review of the Stereo lithography 3D Printing Process and the Effect of Parameters on Quality
...Show More Authors

Stereo lithography (SLA) three-dimensional (3D) printing process is a type of additive manufacturing techniques that uses digital models from computer-aided design to automatically produce customized 3D objects. Around 30 years, it has been widely utilized in the manufacturing, design, engineering, industrial sectors and its applications in dentistry for manufacturing prosthodontics are very important. The stereo lithography technology is highly regarded because it can produce items with excellent precision especially when selecting the best process parameters. This review article offers a useful and scientific summary of SLA three-dimensional printing technology and its brief history. The specific type of 3D printers which is SLA type b

... Show More
View Publication Preview PDF
Scopus (20)
Crossref (21)
Scopus Crossref
Publication Date
Sun Jun 30 2024
Journal Name
Wasit Journal For Pure Sciences
Design Polynomial IIR Digital Filters of the Integer Parameters Space Use to Compress Image Data
...Show More Authors

Polynomial IIR digital filters play a crucial role in the process of image data compression. The main purpose of designing polynomial IIR digital filters of the integer parameters space and introduce efficient filters to compress image data using a singular value decomposition algorithm. The proposed work is designed to break down the complex topic into bite-sized pieces of image data compression through the lens of compression image data using Infinite Impulse Response Filters. The frequency response of the filters is measured using a real signal with an automated panoramic measuring system developed in the virtual instrument environment. The analysis of the output signal showed that there are no limit cycles with a maximum radius

... Show More
View Publication
Crossref
Publication Date
Thu Oct 29 2020
Journal Name
Indian Journal Of Forensic Medicine & Toxicology
Testing the New Parameters affecting The Outcome of Extracorporeal Shockwave Lithotripsy for Upper Ureteric Stones
...Show More Authors

Background: Extracorporeal Shock wave lithotripsy (ESWL) is widely used in treating patients with ureteralstones because it is effective, safe, and noninvasive. Based on factors such as size and the location of stones,there is a significant variation in the overall stone-free rate (SFR).Aim of the study: To evaluate the effect of ureteral wall thickness (UWT), stone attenuation, the time fromfirst attack of pain till first session of ESWL and stone/ rib density on the outcome of SWL in the treatmentof upper ureteral stones (UUS).Patient and methods: A prospective study when 127 patients with radio-opaque UUS ranging from 7 to 20mm and treated by ESWL were included in this study. The effect of (stone/ 12th rib) density by KUB, ureter

... Show More
View Publication
Scopus (2)
Crossref (1)
Scopus Crossref
Publication Date
Mon Dec 11 2017
Journal Name
Al-khwarizmi Engineering Journal
ptimization the Parameters of Magnetic Abrasive Process Using Taguchi Method to Improve the Surface Roughness
...Show More Authors

Abstract  

Magnetic abrasive finishing (MAF) process is one of non-traditional or advanced finishing methods which is suitable for different materials and produces high quality level of surface finish where it uses magnetic force as a machining pressure. A set of experimental tests was planned according to Taguchi orthogonal array (OA) L27 (36) with three levels and six input parameters. Experimental estimation and optimization of input parameters for MAF process for stainless steel type 316 plate work piece, six input parameters including amplitude of tooth pole, and number of cycle between teeth, current, cutting speed, working gap, and finishing time, were performed by design of experiment

... Show More
View Publication Preview PDF
Crossref (1)
Crossref