Preferred Language
Articles
/
ijp-869
Correlation of Paschen parameters in magnetized argon plasma
...Show More Authors

A number of glow discharge experiments has been carried out in a relatively large-volume metallic vacuum chamber containing argon at low pressure and immersed in an inhomogeneous magnetic field generated by a solenoidal coil capable of delivering 2100G. Two Paschen curves demonstrating the dependence of the discharge voltage on sparking parameter Pd and magnetic field strength B were deduced. A graphical correlation showing the behaviour of the voltage difference from the two curves on the ratio B/Pd was constructed. Investigations showed a reduction in the nominal impedance of the discharge device of nearly 20% when B reaches a value of 525G. Plasma confinement regions were found around the internal surface of the chamber at the entrance of the electrodes which may be attributed to pressure gradient by JxB effects as well as ExB drifts.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Jul 01 2015
Journal Name
Journal Of Engineering
Effect of Plasma Shot Peening on Mechanical Properties and Fatigue life of AL-Alloys 2024-T3
...Show More Authors

An Investigation of estimated Mechanical Properties of AL-Alloys 2024-T3, which is the most commonly used in industrial applications, been established experimentally. A new novel Plasma Peening techniques had applied for the whole surfaces of the material by CNC-Plasma machine for 48 specimen, and then a new investigation were toke over to figure the amount of change in mechanical properties and estimated fatigue life. It found that improvement was showing a nonlinear behavior according to peening duration time, speed, peening distance, peening number, and amount of effected power on the depth of the material thickness. The major improvement was at medium speed long duration time normal peening distance. Which shows up t

... Show More
View Publication Preview PDF
Publication Date
Sat Jul 28 2018
Journal Name
Journal Of Engineering
Experimental Investigation for the Removal of Toxic Gases from Vehicle Exhaust using Non-Thermal Plasma
...Show More Authors

In this study, the use of non-thermal plasma theory to remove toxic gases emitted from a vehicle was experimentally investigated. A non-thermal plasma reactor was constructed in the form of a cylindrical tube made of Pyrex glass. Two stainless steel rods were placed inside the tube to generate electric discharge and plasma condition, by connecting with a high voltage power supply (up to 40 kV). The reactor was used to remove the contaminants of a 1.25-liter 4-cylinder engine at ambient conditions. Several tests have been carried out for a ranging speed from 750 to 4,500 rpm of the engine and varying voltages from 0 to 32 kV. The gases entering the reactor were examined by a gas analyzer and the gases concentration ratio

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Thu Sep 01 2011
Journal Name
Journal Of Economics And Administrative Sciences
BASES PROOF FOR PERIOD (1.1) FOR CORRELATION CONEFFICIENT
...Show More Authors

مفهوم معامل الارتباط كمقياس يربط بين متغيرين هذا يجلب انتباهنا إلى موضوع الإحصاء في كل المستويات. أكثر من ذلك هناك ثلاث نقاط خاصة هي اعتيادياً نشدد عليها كما يأتي:-

(1 معامل الارتباط هو الدليل المعياري والذي قيمته لا تعتمد على قياسات  

    المتغيرات الأصلية.

 (2قيمته تقع في المدى] 1,1-[ .

&nb

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Dec 30 2023
Journal Name
Iraqi Journal Of Science
The Correlation between SMBH and SFR for Quasars
...Show More Authors

     A Spectroscopic study has been focused in this article to study one of the main types of active galaxies which are quasars, and to be more precise this research focuses on studying the correlation between the main engine of Quasi-Stellar Objects (QSO), the central black hole mass (SMBH) and other physical properties (e.g. the star formation rate (SFR)). Twelve objects have been randomly selected for “The Half Million Quasars (HMQ) Catalogue” published in 2015 and the data collected from Salon Digital Sky survey (SDSS) Dr. 16. The redshift range of these galaxies were between (0.05 – 0.17). The results show a clear linear proportionality between the SMBH and the SFR, as well as direct proportional between the luminosit

... Show More
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Tue Sep 30 2014
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
New Viscosity Correlation for Different Iraqi Oil Fields
...Show More Authors

 

Viscosity is one of the most important governing parameters of the fluid flow, either in the porous media or in pipelines. So it is important to use an accurate method to calculate the oil viscosity at various operating conditions. In the literature, several empirical correlations have been proposed for predicting crude oil viscosity. However, these correlations are limited to predict the oil viscosity at specified conditions. In the present work, an extensive experimental data of oil viscosities collected from different samples of Iraqi oil reservoirs was applied to develop a new correlation to calculate the oil viscosity at various operating conditions either for dead, satura

... Show More
View Publication Preview PDF
Publication Date
Sat Dec 01 2018
Journal Name
Annals Of Medicine And Surgery
Plasma d-dimer level correlated with advanced breast carcinoma in female patients
...Show More Authors

View Publication
Scopus (10)
Crossref (10)
Scopus Crossref
Publication Date
Sat Aug 31 2019
Journal Name
Iraqi Journal Of Physics
Spectroscopic Diagnostic of Cadmium Sulfide Plasma Produced By LIBS
...Show More Authors

Abstract

       The current study was carried out to reveal the plasma parameters such as ,the electron temperature ( ), electron density (ne) , plasma frequency (fp), Debye length ( ) , Debye number (   for  CdS to employ the LIBS for the purpose of analyzing and determining spectral emission lines using . The results of electron temperature for CdS range (0.746-0.856) eV , the electron density(3.909-4.691)×1018 cm-3. Finally ,we discuss plasma parameters of CdS  through  nano second  laser generated plasma .

View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Jul 01 2014
Journal Name
Journal Of The Faculty Of Medicine Baghdad
Serum Leptin levels in ovarian polycystic disease and its correlation to body weight
...Show More Authors

Background: Poly cystic ovary syndrome is a common disorder in women of reproductive age, it is associated with disturbance of reproductive, endocrine and metabolic functions. The pathophysiology of PCOS appears to be multifactorial and polygenic. Leptin seems to play an important role in pathophysiology of PCOS especially in women with BMI ≥25kg/m2. Objectives: To assess leptin level in both PCOS and healthy women and explore the relation to their body weight and body mass index. Patient and Methods: A total of 120 women were enrolled in this study, 60 women (50%) had PCOS (study group) and the reminder 60 women (50%) were healthy women and considered as control group. BMI was calculated first. Both groups were further sub

... Show More
Preview PDF
Crossref (2)
Crossref
Publication Date
Mon Mar 01 2021
Journal Name
Iraqi Journal Of Agricultural Sciences
CORRELATION STUDY BETWEEN THREE DIFFERENT GENES EXPRESSION AND CHRONIC MYELOID LEUKEMIA IN IRAQ
...Show More Authors

The following study was conducted to investigate the correlation between the expression of three different genes (NOB1, DDX47, CD101( with the occurrence and development of chronic myeloid leukemia (CML) in Iraq. The difference in the expression of these genes between patients and healthy controls was studied. Moreover the correlation of age and gender with CML occurrence and comparing with control was also examined. Results showed significant increases in mean of gene expression level (ΔCt) of patient groups for all genes compared to the corresponding ΔCt means in control group, also the gene expression folding (2-ΔΔCt) reflect significant differences in the expression of these genes and CD101, mRNA showed the highest level in CML pati

... Show More
Publication Date
Wed Jun 30 2021
Journal Name
Journal Of Economics And Administrative Sciences
A Comparison between robust methods in canonical correlation by using empirical influence function
...Show More Authors

       Canonical correlation analysis is one of the common methods for analyzing data and know the relationship between two sets of variables under study, as it depends on the process of analyzing the variance matrix or the correlation matrix. Researchers resort to the use of many methods to estimate canonical correlation (CC); some are biased for outliers, and others are resistant to those values; in addition, there are standards that check the efficiency of estimation methods.

In our research, we dealt with robust estimation methods that depend on the correlation matrix in the analysis process to obtain a robust canonical correlation coefficient, which is the method of Biwe

... Show More
View Publication Preview PDF
Crossref