Preferred Language
Articles
/
ijp-869
Correlation of Paschen parameters in magnetized argon plasma

A number of glow discharge experiments has been carried out in a relatively large-volume metallic vacuum chamber containing argon at low pressure and immersed in an inhomogeneous magnetic field generated by a solenoidal coil capable of delivering 2100G. Two Paschen curves demonstrating the dependence of the discharge voltage on sparking parameter Pd and magnetic field strength B were deduced. A graphical correlation showing the behaviour of the voltage difference from the two curves on the ratio B/Pd was constructed. Investigations showed a reduction in the nominal impedance of the discharge device of nearly 20% when B reaches a value of 525G. Plasma confinement regions were found around the internal surface of the chamber at the entrance of the electrodes which may be attributed to pressure gradient by JxB effects as well as ExB drifts.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Sep 03 2018
Journal Name
Al-academy
Metaphorical correlation in the contemporary sculpture

The present research is concerned with the way in which different dialects interact with each other in contemporary sculpture through the use of the metaphor for various shapes, meanings and materials and placing them in contexts that conflict with the familiar. These attempts come in harmony with the spirit of the times in seeking exoticism, surprise and splendor as a means of renewal. modern Art . Therefore, the research was divided into four axes, the first of which included the research problem, its importance and its aim, which is to attempt to uncover the metaphorical metaphorical relational mechanism in modern sculpture. The second axis included the theoretical framework. The third axis included the research procedures of determin

... Show More
Crossref
View Publication Preview PDF
Publication Date
Fri Sep 05 2014
Journal Name
International Journal Of Pharmacy And Pharmaceutical Sciences0975-1491
THE CORRELATION BETWEEN FRAMINGHAM RISK SCORE AND THE CLINICAL AND BIOCHEMICAL PARAMETERS THAT MEASURE FUNCTIONAL DISABILITY AND DISEASE ACTIVITY IN IRAQI PATIENTS WITH RHEUMATOID ARTHRITIS

Objective: Rheumatoid arthritis (RA) patients have increased morbidity and mortality from premature cardiovascular (CV) disease (CVD). Framingham risk score (FRS) is a simplified coronary prediction tool developed to enable clinicians to assess the risk of a cardiovascular event and to identify candidate patients for risk factors modifications worldwide. The predictive ability of the FRS varies between populations, ethnic groups, and socio-economic status. The aim of this study is to find if there is any correlation between the Framingham risk score and the inflammatory and biochemical parameters used to measure disease activity and functional ability in Iraqi patients with active RA.

View Publication
Publication Date
Tue Sep 11 2018
Journal Name
Iraqi Journal Of Physics
Electrical glow discharges and plasma parameter of planar sputtering system for silver target

DC planar sputtering system is characterized by varying discharge potential of (250-2000 volt) and Argon gas pressures of (3.5×10-2 – 1.5) mbar. The breakdown voltage for silver electrode was studied with a uniform electric field at different discharge distances, as well as plasma parameters. The breakdown voltage is a product of the Argon gas pressure inside the chamber and gab distance between the electrodes, represent as Paschen curve. The Current-voltage characteristics curves indicate that the electrical discharge plasma is working in the abnormal glow region. Plasma parameters were found from the current-voltage characteristics of a single probe positioned at the inter-cathode space. Typical values of the electron temperature an

... Show More
Crossref
View Publication Preview PDF
Publication Date
Sun Jul 30 2023
Journal Name
Iraqi Journal Of Science
Development of Low-Temperature Atmospheric Plasma Jet Sources for Biological Applications

     The research aims to develop and build a plasma jet system operating under atmospheric pressure.for biological purposes. The advanced plasma system consists of a power supply and a plasma torch. The source of the development of the system is a previous laboratory system that was developed by changing the voltage and frequency of the power supply, as the power provider equips the system with a voltage in the form of a sine wave whose value is fixed at about (7.5kV) peak to peak and its frequency is about (28 kHz). The plasma torch consists of a teflon tube with of width of (10 m ) located at (10mm)  from the end of the tube. The current waveform and voltage wave were measured using a current and voltage sensor and an oscilloscop

... Show More
Scopus (2)
Crossref (2)
Scopus Crossref
View Publication Preview PDF
Publication Date
Tue Feb 01 2022
Journal Name
Iraqi Journal Of Science
Some physical properties of SiO2 laser induced plasma

In this work; Silicon dioxide (SiO2) plasma plume was prepared by laser induced plasma (LIP). The electron number density, plasma frequency and Debye length were calculated by reading the data of I-V curve of Langmuir probe which was used as a diagnostic method of measuring plasma properties. Pulsed Nd:YAG laser was used for measuring the electron number density of SiO2 plasma plume under vacuum environment with varying both vacuum pressure and axial distance from the target surface. Some physical properties of the plasma generated such as electron density, plasma frequency and Debye length have been measured experimentally and the effects of vacuum pressure and Langmuir probe distance from the target were studied on those variables. An

... Show More
View Publication Preview PDF
Publication Date
Thu Nov 04 2021
Journal Name
Optik - International Journal For Light And Electron Optics
Plasma parameters of Au nano-particles ablated on porous silicon produced via Nd-YAG laser at 355 nm for sensing NH3 gas

The current study aimed the syntheses and characterizations of Gold nanoparticles (Au NPs) using a laser ablation Q-switched Nd: YAG laser with a wave-length of 355 nm at a variety of laser pulse energies (E) and deposited on porous silicon (PS). Optical emission spectrometer was used to diagnosed medium air to study gold plasma characteristics and prepared Au nanoparticles. The laser pulse energy influence has been studied on the plasma characteristics in air. The data showed the emergence of the ionic (Au II) spectral emission lines in the gold plasma emission spectrum. XRD has been utilized to examine structural characteristics. Moreover, AFM results 37.2 nm as the mean value of the diameter that is coordinated in a shape similar to the

... Show More
Publication Date
Sat Jan 01 2022
Journal Name
Optik
Plasma parameters of Au nano-particles ablated on porous silicon produced via Nd-YAG laser at 355 nm for sensing NH3 gas

a laser ablation Q-switched Nd: YAG laser with a wave-length of 355 nm at a variety of laser pulse energies (E) and deposited on porous silicon (PS). Optical emission spectrometer was used to diagnosed medium air to study gold plasma characteristics and prepared Au nanoparticles. The laser pulse energy influence has been studied on the plasma characteristics in air. The data showed the emergence of the ionic (Au II) spectral emission lines in the gold plasma emission spectrum. XRD has been utilized to examine structural characteristics. Moreover, AFM results 37.2 nm as the mean value of the diameter that is coordinated in a shape similar to the rod that appears for Au NPs, in addition to that, TEM has been an indication of the fact that syn

... Show More
Scopus (32)
Crossref (29)
Scopus Clarivate Crossref
View Publication
Publication Date
Wed Nov 27 2019
Journal Name
Iraqi Journal Of Science
Utilizing Cold Plasma in Preparing Silver Nanoparticle from Origanum Vulgare

     In this research, we obtained nanoparticles (NPs) using a type of microwave (cold plasma) and water extract from Origanum vulgare with the addition of silver nitrate (AgNO3) solution. Silver nanoparticles are characterized by high production techniques. Experimental factors such as morphology, structure, optical properties and active compounds of the nanoparticle extract were studied through specific tests such as morphology, UV spectroscopy, FE-SEM, FT-IR, and Atomic Force Microscopy (AFM). Plants were used in manufacturing the nanoparticles, as plants are well known for their accessibility and applicability in different pathological areas. The current research provides information on the Green Union System of N

... Show More
Scopus (3)
Scopus Crossref
View Publication Preview PDF
Publication Date
Sun Feb 10 2019
Journal Name
Iraqi Journal Of Physics
The role of atmospheric non-thermal plasma in the bacteria inactivation

Non-thermal atmospheric pressure plasma has emerged as a
new promising tool in medicine and biology. In this work, A DBD
system was built as a source of atmospheric pressure non-thermal
Plasma suitable for clinical and biological applications. E. coli and
staphylococcus spp bacteria were exposed to the DBD plasma for a
period of time as inactivation (sterilization) process. A series of
experiments were achieved under different operating conditions. The
results showed that the inactivation, of the two kinds of bacteria, was
affected (increasing or decreasing) according to operation conditions
because they affects, as expected, the produced plasma properties
according to those conditions.

Crossref
View Publication Preview PDF
Publication Date
Sun Oct 01 2023
Journal Name
History Of Medicine
Correlation of Afamin with oxidative stress in GDM

It is becoming a public health issue to predict which expectant women will develop gestational diabetes mellitus (GDM). The goal of this case control research is to investigate the role of maternal oxidative stress levels in the first, second, and third trimesters, as well as other factors, in the development of gestational diabetes mellitus (GDM). Methods Between October and December 2021, 142 women participated in this research. The 101 GDM patients were split into three groups based on their gestation (T1, T2, and T3), and 41 healthy pregnant women were chosen as the comparison group. TAS and TOS levels of oxidative stress and XO were calculated using a Spectrophotometer for colorimetric techniques; fasting and random sugar levels, as

... Show More