Preferred Language
Articles
/
ijp-861
The axial profile of plasma characteristics of cylindrical magnetron sputtering device
...Show More Authors

In the present work, a d.c. magnetron sputtering system was designed and fabricated. The chamber of this system was includes from two copper coaxial cylinders where the inner one used as a cathode (target) while the outer one used as the anode with Solenoid magnetic coil located on the outer cylinder (anode). The axial profile of magnetic field for various coil current (from 2A to 14 A) are shown. The plasma characteristics in the normal glow discharge region are diagnostics by the 2.2mm diameter Langmuir probe with different length along the cathode and located at different radial positions 1cm and 2cm from the cathode surface. The result of this work shows that, the electron energy distributions at different radial positions along the cathode surface are non-uniform. Therefore, the plasma characteristics at these radial positions along the cathode surface are non-uniform. So that, the ion bombardment along the cathode are non-uniform in this glow discharge region

View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue May 01 2018
Journal Name
Journal Of Physics: Conference Series
Synthesis of ZnS Quantum Dots for QDs-LED hybrid device with different cathode materials
...Show More Authors

View Publication
Scopus (12)
Crossref (7)
Scopus Clarivate Crossref
Publication Date
Tue Apr 22 2025
Journal Name
Journal Of Physical Education
The effect of special exercises using a designer device and added relative weights to develop some of the physical abilities of volleyball players
...Show More Authors

View Publication
Publication Date
Sun Mar 03 2013
Journal Name
Baghdad Science Journal
Effect of Methotrexate on the Liver Enzymes and Lipid Profile in Adult Female Albino Mice
...Show More Authors

Methotrexate (MTX) was used for treatment of malignancies and now is widely used in treatment of rheumatoid arthritis. In this research the evaluation of the effects of MTX on some liver enzymes and lipid profile was studied. Twenty four adult female mice divided into three groups (8 mice each). The first two groups were treated with MTX while the third group was used as a control. MTX was intraperitoneally given at 50 µg/ml and 75 µg/ml to the first and second groups respectively for 35 days ,whereas the control group was intraperitoneally injected with normal saline. The results showed a significant (p<0.05) increase in serum levels of glutamic oxaloacetate transaminase (GOT) , glutamic pyruric transaminase (GPT), Alkaline pho

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Nov 30 2021
Journal Name
Indian Journal Of Forensic Medicine & Toxicology
The role of vitamin D3 in improving lipid profile in type 2 diabetes patients with
...Show More Authors

Publication Date
Sun Dec 01 2002
Journal Name
Iraqi Journal Of Physics
The Role of Plasm Lipid Profile on RBC Aggregation and Sedimentation Changes in Diabetic Patients
...Show More Authors

The aggregation capacity of human reb blood cells lies between that of the non- aggregated arythrocyte and the remarkably full sedimentation. As the ability to aggregate is atributed to many factors such as the availability of macromolecules and plasma lipids, the role of plasm lipid profile on RBC aggregation and sedimentation changes in normal and diabetic patients is studied.Also serum lipid profile measurement (Total cholesterol, Triglyceride, HDL, LDL, VLDL) in normal and diabetic subjects were made. The principle of measurement includes detecting the transmitted laser light through a suspension of 10% diluted red blood cells in plasma. In all diabetics, the raulux formation and sedimentation rate is enhanced.

View Publication Preview PDF
Publication Date
Tue May 01 2012
Journal Name
Iraqi Journal Of Physics
Argon plasma needle source
...Show More Authors

Non thermal argon plasma needle at atmospheric pressure was generated. The experimental set up is based on very simple and low cost electric components that generate electrical field sufficiently high at the electrodes to ionize various gases, which flow at atmospheric pressure. The high d.c power supply is 7.5kV peak to peak, the frequency of the electrical field is 28kHz, and the plasma power less than 15W. The plasma is generated using only one electrode. In the present work the voltage and current discharge waveform are measured. Also the temperature of the working Ar gas at different gas flow and distances from the plasma electrode tip was recorded

View Publication Preview PDF
Publication Date
Thu Nov 01 2018
Journal Name
Journal Of Economics And Administrative Sciences
Effect of the professional skepticism characteristics of the auditor on audit qualit
...Show More Authors

The professional skepticism is one of the fundamental concepts necessary for practicing the audit profession, without which the auditor can not reach a reasonable assurance as to the correctness of the evidence and the information obtained by the auditing department. The auditor's possession of the characteristics of professional skepticism and his practice of professional skepticism during the audit process lead to an increase The quality of audit and thus raise the confidence of the financial community in the audit profession again after the exposure of several crises led to the loss of financial society confidence in the audit profession.

The aim of the study is to measure the impact of professional sk

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Thu Apr 07 2016
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
DETECTION OF MICROBIAL CONTAMINATION IN SOME TYPES OF FLOUR THAT AVAILABLE IN LOCAL MARKETS USING BACTRAC DEVICE 3400: DETECTION OF MICROBIAL CONTAMINATION IN SOME TYPES OF FLOUR THAT AVAILABLE IN LOCAL MARKETS USING BACTRAC DEVICE 3400
...Show More Authors

A microbial study conducted for a number of flour samples (30 samples) Uses in the bakery ovens in various areas of the city of Baghdad, by used the conventional methods used in laboratories in microbial tests and compared with the modern techniqueby usedof BacTrac Device 3400 equipped from SY-LAB Impedance analysersAustrian company.The results of two ways showed (The conventional way and BacTrac Device test)that the total counts of aerobic bacteria, coliform bacteria, StaphylococcusSpp. bacteria, Bacillus cereus bacteria and yeasts and molds,Most of them were within the permissible borders in the Iraqi standard for grain and its products With free samples from SalmonellaSpp. bacteria, and that the screening by BacTrac device are shorten

... Show More
View Publication Preview PDF
Publication Date
Sat Jan 01 2022
Journal Name
3rd International Scientific Conference Of Alkafeel University (iscku 2021)
Simulation and investigation of the ICP plasma torch’s electrical and thermal properties
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Fri Jan 01 2021
Journal Name
E3s Web Of Conferences
Experimental Investigation of Bearing Capacity of Screw Piles and Excess Porewater Pressure in Soft Clay under Static Axial Loading
...Show More Authors

In this study, the behavior of screw piles models with continuous helix was studied by conducting laboratory experimental tests on a single screw pile that has several aspect ratios (L/D) under the influence of static axial compression loads. The screw piles were inserted in a soft soil that has a unit weight of 18.72 kN/m3 and moisture content of 30.19%. Also, the soil has a liquid limit of 55% and a plasticity index of 32%. A physical laboratory model was designed to investigate the ultimate compression capacity of the screw pile and measure the generated porewater pressure during the loading process. The bedding soil was prepared according to the field unit weight and moisture content and the failure load was assumed correspondin

... Show More
View Publication Preview PDF
Scopus (7)
Crossref (6)
Scopus Crossref