Preferred Language
Articles
/
ijp-861
The axial profile of plasma characteristics of cylindrical magnetron sputtering device
...Show More Authors

In the present work, a d.c. magnetron sputtering system was designed and fabricated. The chamber of this system was includes from two copper coaxial cylinders where the inner one used as a cathode (target) while the outer one used as the anode with Solenoid magnetic coil located on the outer cylinder (anode). The axial profile of magnetic field for various coil current (from 2A to 14 A) are shown. The plasma characteristics in the normal glow discharge region are diagnostics by the 2.2mm diameter Langmuir probe with different length along the cathode and located at different radial positions 1cm and 2cm from the cathode surface. The result of this work shows that, the electron energy distributions at different radial positions along the cathode surface are non-uniform. Therefore, the plasma characteristics at these radial positions along the cathode surface are non-uniform. So that, the ion bombardment along the cathode are non-uniform in this glow discharge region

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Jan 03 2015
Journal Name
Journal Of Engineering And Development
3D Presentation for Baghdad University Buildings Using Total Station Device
...Show More Authors

capable of the measuring with a high degree of precision in a single instrument. Total stations device are used for station setting up, setting-outmany points from one station. Their major purpose of this work is to take advantage of total station for setting up building and to establish 3D representation using AutoCAD program. The area of the study was Civil Engineering Department at Baghdad University campus AL Jadiriyah. The completion of the work is done in two stages; 1. The field work: In this stage, the Total Station Nikon Nivo-5C was selected for the current study. This device was measured horizontal and vertical distance, elevations, and coordinates from a single set up. This data directly stored on memory. 2. The office work: In t

... Show More
Publication Date
Wed Oct 05 2016
Journal Name
Al-academy
The Characteristics of Art forms in the Byzantine icons painting
...Show More Authors

The problem with research in the question of whether art forms in the religious icon Byzantine, heiress docility and tradition craftsman arts civilizations of the above? ... And if you are well, you helped a quotation on the entry of strange ideas rampant within religious traditions, and are prompted to do Movement rejected prohibition, and the outbreak of the icons war? ... Or is it, in fact - and as researcher finds - the result of a need communication between the religious and the recipient organization in the establishment of a deliberative speech, be visible, along with reading it and audible? .. And lies the importance of this study is being added technical knowledge of the library that will enrich researchers and scholars in this

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Jan 01 2019
Journal Name
Journal Of Human Sport And Exercise - 2019 - Spring Conferences Of Sports Science
The use of the electrical stimulation device for the muscles in the limit determines the elbow joint during the lifting of the disabled weightlifting players
...Show More Authors

View Publication
Scopus (1)
Scopus Clarivate Crossref
Publication Date
Sun Dec 01 2002
Journal Name
Iraqi Journal Of Physics
The Role of Plasm Lipid Profile on RBC Aggregation and Sedimentation Changes in Diabetic Patients
...Show More Authors

The aggregation capacity of human reb blood cells lies between that of the non- aggregated arythrocyte and the remarkably full sedimentation. As the ability to aggregate is atributed to many factors such as the availability of macromolecules and plasma lipids, the role of plasm lipid profile on RBC aggregation and sedimentation changes in normal and diabetic patients is studied.Also serum lipid profile measurement (Total cholesterol, Triglyceride, HDL, LDL, VLDL) in normal and diabetic subjects were made. The principle of measurement includes detecting the transmitted laser light through a suspension of 10% diluted red blood cells in plasma. In all diabetics, the raulux formation and sedimentation rate is enhanced.

View Publication Preview PDF
Publication Date
Sun Mar 03 2013
Journal Name
Baghdad Science Journal
Effect of Methotrexate on the Liver Enzymes and Lipid Profile in Adult Female Albino Mice
...Show More Authors

Methotrexate (MTX) was used for treatment of malignancies and now is widely used in treatment of rheumatoid arthritis. In this research the evaluation of the effects of MTX on some liver enzymes and lipid profile was studied. Twenty four adult female mice divided into three groups (8 mice each). The first two groups were treated with MTX while the third group was used as a control. MTX was intraperitoneally given at 50 µg/ml and 75 µg/ml to the first and second groups respectively for 35 days ,whereas the control group was intraperitoneally injected with normal saline. The results showed a significant (p<0.05) increase in serum levels of glutamic oxaloacetate transaminase (GOT) , glutamic pyruric transaminase (GPT), Alkaline pho

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Nov 30 2021
Journal Name
Indian Journal Of Forensic Medicine & Toxicology
The role of vitamin D3 in improving lipid profile in type 2 diabetes patients with
...Show More Authors

Publication Date
Mon Aug 04 2014
Journal Name
Photonic Sensors
Crystalline structure and surface morphology of tin oxide films grown by DC reactive sputtering
...Show More Authors

View Publication
Scopus (9)
Crossref (6)
Scopus Crossref
Publication Date
Mon Dec 01 2014
Journal Name
Photonic Sensors
Crystalline Structure and Surface Morphology of Tin Oxide Films Grown by DC Reactive Sputtering
...Show More Authors

Abstract: Tin oxide thin films were deposited by direct current (DC) reactive sputtering at gas pressures of 0.015 mbar – 0.15 mbar. The crystalline structure and surface morphology of the prepared SnO2 films were introduced by X-ray diffraction (XRD) and atomic force microscopy (AFM). These films showed preferred orientation in the (110) plane. Due to AFM micrographs, the grain size increased non-uniformly as the working gas pressure increased.

Preview PDF
Publication Date
Sun Jul 28 2019
Journal Name
Open Access Macedonian Journal Of Medical Sciences
Value of Combination of Standard Axial and Thin-Section Coronal Diffusion-weighted Imaging in Diagnosis of Acute Brainstem Infarction
...Show More Authors

AIM: To determine the value of the combination of thin-section 3 mm ‎coronal and standard ‎axial DWI and their impact in facilitating the diagnosis of ‎‎acute brainstem infarction. METHODS: A cross-sectional study conducted from the 1st of April 2017 to the end of February 2018 on 100 consecutive patients (66% were male, and 34% were female) with isolated acute ischemic infarction in the ‎brainstem. The abnormal MRI findings concerning the ischemic lesions were interpreted on standard axial 5 mm and thin-section coronal 3mm DWI. RESULTS: The mean age of the studied group was 69.2 ± 4.3 for male and 72.3 ± 2.5 years. The standard axial DWI can diagnose 20%, 6.7% and 6.7% of the infarctions in midbrain, pons an

... Show More
View Publication
Scopus (3)
Crossref (3)
Scopus Crossref
Publication Date
Tue May 01 2012
Journal Name
Iraqi Journal Of Physics
Argon plasma needle source
...Show More Authors

Non thermal argon plasma needle at atmospheric pressure was generated. The experimental set up is based on very simple and low cost electric components that generate electrical field sufficiently high at the electrodes to ionize various gases, which flow at atmospheric pressure. The high d.c power supply is 7.5kV peak to peak, the frequency of the electrical field is 28kHz, and the plasma power less than 15W. The plasma is generated using only one electrode. In the present work the voltage and current discharge waveform are measured. Also the temperature of the working Ar gas at different gas flow and distances from the plasma electrode tip was recorded

View Publication Preview PDF