In this research velocity of moving airplane from its recorded digital sound is introduced. The data of sound file is sliced into several frames using overlapping partitions. Then the array of each frame is transformed from time domain to frequency domain using Fourier Transform (FT). To determine the characteristic frequency of the sound, a moving window mechanics is used, the size of that window is made linearly proportional with the value of the tracked frequency. This proportionality is due to the existing linear relationship between the frequency and its Doppler shift. An algorithm was introduced to select the characteristic frequencies, this algorithm allocates the frequencies which satisfy the Doppler relation, beside that the tracked frequencies was chosen to be the most occurred frequencies in the power spectrum. Several sizes of the overlap windows have been tested to study the effect of window size on the accuracy of the determined radial velocity of the moving airplane.
A new, Simple, sensitive and accurate spectrophotometric methods have been developed for the determination of sulfanilamide (SNA) drug in pure and in synthetic sample. This method based on the reaction of sulfanilamide (SNA) with 1,2-napthoquinone-4-sulphonic acid (NQS) to form N-alkylamono naphthoquinone by replacement of the sulphonate group of the naphthoquinone sulphonic acid by an amino group. The colored chromogen shows absorption maximum at 455 nm. The optimum conditions of condensation reaction forms were investigated by: (1) univariable method, by optimizing the effect of experimental variables; (different bases, reagent concentration, borax concentration and reaction time), (2) central composite design (CCD) including
... Show MoreSimple, rapid and sensitive spectrophotometric method was proposed for the analysis of metoclopramide hydrochloride (MPH) in pure form as well as in pharmaceutical tablets. The method is based on the diazotization reaction of MPH with sodium nitrite in hydrochloric acid medium to form diazonium salt, which is coupled with 1-naphthol in sodium hydroxide medium to form azo dye, showing absorption maxima at 550 nm. Beer’s law is obeyed in the concentration range of 0.4 – 18 µg mL-1 of MPH with detection limit 0.5448 µg mL-1. The molar absorptivity and Sandell’s sensitivity are 3.4969 × 104 L mol-1 cm-1 and 0.0101 µg cm-2, respectively. The method was successfully applied to the determination of MPH in pharmaceutical tablets with
... Show MoreBackground: The incidence of maternal mortality in
placenta previa accrete is 7%,and its preoperative
diagnosis is of a great value.
Objective: to evaluate the efficacy of transabdominal
color Doppler ultrasound in diagnosing placenta
previa accreta and inccreta. Color Doppler imaging
criteria used in: includes diffuse parenchymal
placental lacunar flow, focal intra parenchymal
placental lacunar flow and bladder uterine serosa
interphase hyper-vascularity.
Design: Prospective study on patients from
January2007 to January 2008.
Patients and method: 48patients with one caesarean
section or more and with persistent anterior placenta
previa diagnosed by transabdominal ultrasound were
examined by c
The gravity method is a measurement of relatively noticeable variations in the Earth’s gravitational field caused by lateral variations in rock's density. In the current research, a new technique is applied on the previous Bouguer map of gravity surveys (conducted from 1940–1950) of the last century, by selecting certain areas in the South-Western desert of Iraqi-territory within the provinces' administrative boundary of Najaf and Anbar. Depending on the theory of gravity inversion where gravity values could be reflected to density-contrast variations with the depths; so, gravity data inversion can be utilized to calculate the models of density and velocity from four selected depth-slices 9.63 Km, 1.1 Km, 0.682 Km and 0.407 Km.
... Show MoreSteganography is defined as hiding confidential information in some other chosen media without leaving any clear evidence of changing the media's features. Most traditional hiding methods hide the message directly in the covered media like (text, image, audio, and video). Some hiding techniques leave a negative effect on the cover image, so sometimes the change in the carrier medium can be detected by human and machine. The purpose of suggesting hiding information is to make this change undetectable. The current research focuses on using complex method to prevent the detection of hiding information by human and machine based on spiral search method, the Structural Similarity Index Metrics measures are used to get the accuracy and quality
... Show MoreThe permeability determination in the reservoirs that are anisotropic and heterogeneous is a complicated problem due to the limited number of wells that contain core samples and well test data. This paper presents hydraulic flow units and flow zone indicator for predicting permeability of rock mass from core for Nahr-Umr reservoir/ Subba field. The Permeability measurement is better found in the laboratory work on the cored rock that taken from the formation. Nahr-Umr Formation is the main lower cretaceous sandstone reservoir in southern of Iraq. This formation is made up mainly of sandstone. Nahr-Umr formation was deposited on a gradually rising basin floor. The digenesis of Nahr-Umr sediments is very important du
... Show More|
Ground Penetrating Radar (GPR) is a nondestructive geophysical technique that uses electromagnetic waves to evaluate subsurface information. A GPR unit emits a short pulse of electromagnetic energy and is able to determine the presence or absence of a target by examining the reflected energy from that pulse. GPR is geophysical approach that use band of the radio spectrum. In this research the function of GPR has been summarized as survey different buried objects such as (Iron, Plastic(PVC), Aluminum) in specified depth about (0.5m) using antenna of 250 MHZ, the response of the each object can be recognized as its shapes, this recognition have been performed using image processi |
Twosimple, sensitive,accurate, and precise spectrophotometric methods have been developed for the determination of chlorpromazine – HCl in pure form and pharmaceutical formulation. The first method involved treatment of cited drug with a measured excess of permanganate in acid medium and the unreacted oxidant was measured at 525 nm. The second method involves the reaction of the drug with potassium permanganate in the presence of sodium hydroxide to produce a bluish – green colored manganite which is measurable at 610nm. All the experimental variables affecting the development of the manganite ions were investigatedand conditions were optimized. Working linearity ranges were 5-45 µg.mL-1and 1-20 µg.mL-1 by two methods respectively. Th
... Show MoreCopula modeling is widely used in modern statistics. The boundary bias problem is one of the problems faced when estimating by nonparametric methods, as kernel estimators are the most common in nonparametric estimation. In this paper, the copula density function was estimated using the probit transformation nonparametric method in order to get rid of the boundary bias problem that the kernel estimators suffer from. Using simulation for three nonparametric methods to estimate the copula density function and we proposed a new method that is better than the rest of the methods by five types of copulas with different sample sizes and different levels of correlation between the copula variables and the different parameters for the function. The
... Show MoreIn the present study twenty samples of human urine were taken
from healthy male and female with different of: ages, occupation and
place of residence. These samples were collected from the hospital to
measure the concentration of radon gas in human urine by using one
of solid state nuclear track detectors LR-115.
The results obtained of the concentrations of radon in healthy human
urine are varying from 2.12×10-3 Bq.l-1 to 4.42×10-3 Bq.l-1 and
these values are less than the allowed limits 12.3×10-3 Bq.l-1.