Preferred Language
Articles
/
ijp-772
Argon plasma needle source
...Show More Authors

Non thermal argon plasma needle at atmospheric pressure was generated. The experimental set up is based on very simple and low cost electric components that generate electrical field sufficiently high at the electrodes to ionize various gases, which flow at atmospheric pressure. The high d.c power supply is 7.5kV peak to peak, the frequency of the electrical field is 28kHz, and the plasma power less than 15W. The plasma is generated using only one electrode. In the present work the voltage and current discharge waveform are measured. Also the temperature of the working Ar gas at different gas flow and distances from the plasma electrode tip was recorded

View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Jun 01 2020
Journal Name
Iop Conference Series: Materials Science And Engineering
Flow Production Rate of Hard Photons Probes of Quark–Anti Quark Annihilation Processes at Plasma Phase
...Show More Authors

The flow emission rate of hard photons from lowest order the QCD processes for quark-anti quark annihilation processes in plasma media at high temperatures (175, 200, 225, 250 and 275 MeV) have been study. In these framework photons, the flow photons emission is calculate according to quark-antiquark annihilation using the quantum chromodynamic theory and solves the ultrarelativistic equation with MATLAP program. Due to the results, we show increases flow photons rate with increases strength coupling and increases with increases temperature of media, it indicate that logarithmically divergent thermal effect on photons product. The critical temperature (Tc=155 to 195 MeV) effect on the quarks confined in hadronic matter phase, it is importan

... Show More
View Publication Preview PDF
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Sat Jan 01 2022
Journal Name
Technologies And Materials For Renewable Energy, Environment And Sustainability: Tmrees21gr
Effect of non-thermal plasma by FE-DBD scheme on lipids in blood in vivo study
...Show More Authors

This study illustrates the impact of non-thermal plasma (Cold Atmospheric Plasma CAP) on the lipids blood, the study in vivo. The lipids are (cholesterol, HDL-Cholesterol, LDL-Cholesterol and triglyceride) are tested. (FE-DBD) scheme of probe diameter 4cm is used for this purpose, and the output voltage ranged from (0-20) kV with variable frequency (0-30) kHz. The effect of non-thermal atmospheric plasma on lipids were studied with different exposure durations (20,30) sec. As a result, the longer plasma exposure duration decreases more lipids in blood.

View Publication
Scopus Crossref
Publication Date
Tue Oct 02 2018
Journal Name
Iraqi Journal Of Physics
Effect of electrode separation in magnetron DC plasma sputtering on grain size of gold coated samples
...Show More Authors

In this work, an experimental research on a low voltage DC magnetron plasma sputtering (0-650) volt is used for coating gold on a glass substrate at a constant pressure of argon gas 0.2 mbar and deposition time of 30 seconds. We focused on the effects of operating conditions for the system such as, electrode separation and sputtering current on coated samples under the influence of magnetic flux. Electron temperature and electrons and ions densities are determined by a cylindrical single Langmuir probe. The results show the sensitivity of electrode separation lead to change the plasma parameters. Furthermore, the surface morphology of gold coated samples at different electrode separation and sputtering current were studied by atomic forc

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Tue Oct 08 2002
Journal Name
Iraqi Journal Of Laser
Study of Laser Propagation Parameters in the Underdense Plasma Region Using a Two Dimensional Simulation Code
...Show More Authors

The propagation of laser beam in the underdense deuterium plasma has been studied via computer simulation using the fluid model. An appropriate computer code “HEATER” has been modified and is used for this purpose. The propagation is taken to be in a cylindrical symmetric medium. Different laser wavelengths (1 = 10.6 m, 2 = 1.06 m, and 3 = 0.53 m) with a Gaussian pulse type and 15 ns pulse widths have been considered. Absorption energy and laser flux have been calculated for different plasma and laser parameters. The absorbed laser energy showed maximum for  = 0.53 m. This high absorbitivity was inferred to the effect of the pondermotive force.

View Publication Preview PDF
Publication Date
Sun Jan 01 2023
Journal Name
Plasma Medicine
Thermal Effect of Laser on Silver Nanoparticles Synthesized by the Cold Plasma Method on Cancer Cells
...Show More Authors

In this study, silver nanoparticles (AgNPs) were synthesized using a cold plasma technique and a plasma jet. They were then used to explore how photothermal treatment may be used to treat lung cancer (A549) and normal cells (REF) <i>in vitro</i>. The anti-proliferative activity of these nanoparticles was studied after A549 cells were treated with (AgNPs) at various concentrations (100&#37;, 50&#37;, or 25&#37;) and exposure times (6 or 8 min) of laser after 1 h or 24 h from exposed AgNPs. The highest growth inhibition for cancer cells is (75&#37;) at (AgNPs) concentration (100&#37;) and the period of exposure to the laser is (8 min). Particle size for the prepared samples varied according to the diameter o

... Show More
View Publication
Scopus (1)
Scopus Crossref
Publication Date
Sun Dec 03 2017
Journal Name
Baghdad Science Journal
CFIA-Turbidimetric and Photometric Determination of Vitamin B9 (Folic acid) Using LEDs as a Source of Irradiation and Two Solar Cells as an Energy Transducer
...Show More Authors

A specific, sensitive and simple method was used for the determination of: vitamin B9 (Folic acid) in pure and pharmaceutical formulations using continuous flow injection analysis. The method is based on formation of ion pair compound between folic acid and ammonium molybdate in an aqueous medium to obtain a gray precipitate complex, using homemade; Ayah-6SX1-ST-2D solar cell CFI Analyzer. Optimum parameters was studied to increase the sensitivity for developed method. The linear range for the calibration graph was 0.01-0.6 mMol.L-1 of vitamin B9 and LOD was 131.994 ng/sample with correlation coefficient ( r ) of 0.9810, RSD% was lower than 0.1%, (n=9) for the determination of vitamin B9 at concentration (0.07and 0.5) mMol.L-1 respectiv

... Show More
View Publication Preview PDF
Scopus (3)
Scopus Crossref
Publication Date
Thu Jul 01 2021
The spontaneous emission performance of a quantum emitter coupled to a hybrid plasmonic waveguide with specified output polarization for on-chip plasmonic single-photon source
...Show More Authors

Scopus (4)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Tue May 11 2021
Journal Name
Photonics And Nanostructures - Fundamentals And Applications
The spontaneous emission performance of a quantum emitter coupled to a hybrid plasmonic waveguide with specified output polarization for on-chip plasmonic single-photon source
...Show More Authors

Nowadays, most of the on-chip plasmonic single-photon sources emit an unpolarized stream of single photons that demand a subsequent polarizer stage in a practical quantum cryptography system. In this paper, we numerically demonstrated the coupling of the light emitted from a quantum emitter (QE) at 700 nm wavelength to the propagation mode supported by an on-chip hybrid plasmonic waveguide (HPW) polarization rotator. Our results proved that the light emitted is linearly polarized at 0º, 45º/−45º, and 90º with propagation lengths of 5 μm, 3.3 μm, and 3.9 μm, respectively. Moreover, high power-conversion efficiency was obtained from an applied transverse magnetic (TM) mode (0º-polarization) to a transverse electric (TE) (90º-polari

... Show More
View Publication
Scopus (4)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Wed Dec 30 2020
Journal Name
Al-kindy College Medical Journal
Measurement of plasma fibrinogen and D-dimer in a sample of Iraqi patients with solid malignant tumors
...Show More Authors

Background: Multifactor affect the pathogenesis of thrombosis in solid malignancy; however, a significant role is attributed to the cancer cells ability to interact with and activate the host hemostatic system. [1] 

Hemostasis is highly correlated to tumor growth, angiogenesis and metastasis, modulation of these pathways reflects interesting and promising treatment options in the future. [1]

Most patients with cancer frequently suffer from chronic compensated DIC and have abnormal laboratory coagulation tests without clinical manifestations of thrombosis, which is a subclinical hypercoagulable state that can be detected by varying degrees of activation of blood clotting. The results of laboratory tests in th

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Jun 08 2025
Journal Name
Iraqi Journal Of Medical Sciences
A COMPARATIVE STUDY OF FRUCTOSE, ZINC AND COPPER LEVELS IN SEMINAL PLASMA IN FERTILE AND INFERTILE MEN
...Show More Authors

Background: Human semen contains high concentrations of fructose, zinc (Zn) and copper (Cu) in bound and ionic forms for Zn and Cu. The presence of abnormal levels of fructose and those trace elements may affect spermatogenesis with regard to production, maturation, motility and fertilizing capacity of the spermatozoa.Objective: To evaluate the levels of fructose, Zn and Cu in seminal plasma in different groups of male infertility and to correlate their concentrations with various sperm parameters.Methods: The concentrations of fructose, Zn and Cu were measured in 114 semen samples from normozoospermic, oligozoospermic, astheno-zoospermic, and azoospermic men using the electrothermal-atomic absorption spectrometry for Zn and Cu determinatio

... Show More
View Publication Preview PDF