Non thermal argon plasma needle at atmospheric pressure was generated. The experimental set up is based on very simple and low cost electric components that generate electrical field sufficiently high at the electrodes to ionize various gases, which flow at atmospheric pressure. The high d.c power supply is 7.5kV peak to peak, the frequency of the electrical field is 28kHz, and the plasma power less than 15W. The plasma is generated using only one electrode. In the present work the voltage and current discharge waveform are measured. Also the temperature of the working Ar gas at different gas flow and distances from the plasma electrode tip was recorded
The current study was conducted for studying the impact of cold plasma on the expression level of three genes that participate in the biosynthesis of the phenylpropanoid pathway in Ocimum basilicum. These studied genes were cinnamate 4-hydroxylase (c4h), 4-coumarate CoA ligase (4cl), and eugenol O-methyl transferase (eomt). Also, the cold plasma impact was studied on the essential oil components and their relation with the gene expression level. The results demonstrated that cold plasma seeds germination of the treated groups 2 (initially for 3 minutes and 3 minutes after 7 days) ,and group 3(initially for 5 minutes and 3 minutes after 7 days) were faster than the control group. Also, the height average of the mature plants of
... Show MoreIn this study, silver nanoparticles (AgNPs) were synthesized using a cold plasma technique and a plasma jet. They were then used to explore how photothermal treatment may be used to treat lung cancer (A549) and normal cells (REF) <i>in vitro</i>. The anti-proliferative activity of these nanoparticles was studied after A549 cells were treated with (AgNPs) at various concentrations (100%, 50%, or 25%) and exposure times (6 or 8 min) of laser after 1 h or 24 h from exposed AgNPs. The highest growth inhibition for cancer cells is (75%) at (AgNPs) concentration (100%) and the period of exposure to the laser is (8 min). Particle size for the prepared samples varied according to the diameter o
... Show MoreIn this work, an experimental research on a low voltage DC magnetron plasma sputtering (0-650) volt is used for coating gold on a glass substrate at a constant pressure of argon gas 0.2 mbar and deposition time of 30 seconds. We focused on the effects of operating conditions for the system such as, electrode separation and sputtering current on coated samples under the influence of magnetic flux. Electron temperature and electrons and ions densities are determined by a cylindrical single Langmuir probe. The results show the sensitivity of electrode separation lead to change the plasma parameters. Furthermore, the surface morphology of gold coated samples at different electrode separation and sputtering current were studied by atomic forc
... Show MoreThe flow emission rate of hard photons from lowest order the QCD processes for quark-anti quark annihilation processes in plasma media at high temperatures (175, 200, 225, 250 and 275 MeV) have been study. In these framework photons, the flow photons emission is calculate according to quark-antiquark annihilation using the quantum chromodynamic theory and solves the ultrarelativistic equation with MATLAP program. Due to the results, we show increases flow photons rate with increases strength coupling and increases with increases temperature of media, it indicate that logarithmically divergent thermal effect on photons product. The critical temperature (Tc=155 to 195 MeV) effect on the quarks confined in hadronic matter phase, it is importan
... Show MorePlasma electrolytic oxidation and dip chemical coating as fabrication techniques are performed in ambient temperature and pressure, giving a competitive-edge in the commercial applicability. Thus, we proposed new compositions of flower-like hybrid materials, MgO-TiO2-HQ(8-hydroxyquinoline), MgOTiO2-HQ-APY(2-aminopyridine) and MgO-TiO2-HQ-APH(2-aminophenol), as photocatalysis with high corrosion resistance via a combination of plasma electrolytic oxidation and dip chemical coating in which 8-HQ, 2-APY, and 2-APH were used as the organic components. TiO2-HQ-APY and MgO-TiO2-HQ-APH exhibited improved simultaneous electrochemical and photocatalytic performance on photodecomposition of methylene blue (MB) in an aqueous solution in the presence o
... Show MoreThe present study was set to investigate the potential association between the level of Interleukin-6 (IL-6), as a key component of the pro-inflammatory response, with different thalassemia’s biological and clinical features. For this purpose, one hundred fifty blood samples were collected from 100 beta-thalassemia patients, who attended the Genetic Hematology Centre at Ibn Al- Baladi Hospital in Baghdad, Iraq, and 50 healthy subjects who were employed as a control group. IL-6 levels were estimated using an ELISA Kit, whereas other thalassemia-related clinical features (such as HbA, HbF, ferritin, blood transfusions, splenectomy status, and the history of frequent infection) were additionally assessed. The results of the present s
... Show MoreIn the present study, the effect of Zinc nanoparticles on levels of (T3 , T4 and TSH) hormones was investigated. Zinc nanoparticles were synthesized by Laser induced plasma.The Nd: YAG Nd: YAG laser with a wavelength of 1064 nm was used to generate nanomaterials of the elements (zinc) upon collision with target atoms. Plasma generated by different laser intensity is generated. After confirming the preparation of zinc nanoparticles, XRD, AFM was examined, and the effect of these substances on the thyroid gland (T3, T4, TSH) was observed for two doses of each component (1 ml / kg, 4 ml / kg) after conducting a cytotoxicity examination of the lymphocytes of the rats extracted from Rat spleen was 1.8% less toxic to zinc, and as noted The
... Show MoreThis study illustrates the impact of non-thermal plasma (Cold Atmospheric Plasma CAP) on the lipids blood, the study in vivo. The lipids are (cholesterol, HDL-Cholesterol, LDL-Cholesterol and triglyceride) are tested. (FE-DBD) scheme of probe diameter 4cm is used for this purpose, and the output voltage ranged from (0-20) kV with variable frequency (0-30) kHz. The effect of non-thermal atmospheric plasma on lipids were studied with different exposure durations (20,30) sec. As a result, the longer plasma exposure duration decreases more lipids in blood.
The propagation of laser beam in the underdense deuterium plasma has been studied via computer simulation using the fluid model. An appropriate computer code “HEATER” has been modified and is used for this purpose. The propagation is taken to be in a cylindrical symmetric medium. Different laser wavelengths (1 = 10.6 m, 2 = 1.06 m, and 3 = 0.53 m) with a Gaussian pulse type and 15 ns pulse widths have been considered. Absorption energy and laser flux have been calculated for different plasma and laser parameters. The absorbed laser energy showed maximum for = 0.53 m. This high absorbitivity was inferred to the effect of the pondermotive force.