In this work the diode planer magnetron sputtering device was
designed and fabricated. This device consists of two aluminum discs
(8cm) diameter and (5mm) thick. The distance between the two
electrodes is 2cm, 3cm, 4cm and 5cm.
Design and construction a double probe of tungsten wire with
(0.1mm) diameter and (1.2mm) length has been done to investigate
electron temperature, electron and ion density under different
distances between cathode and anode. The probes were situated in
the center of plasma between anode and cathode.
The results of this work show that, when the distance between
cathode and anode increased, the electron temperature decreased.
Also, the electron density increases with the increasing of the
distance between the two electrodes. The behavior of ion density is
similar to that of electrons but the value is higher
Double-layer micro-perforated panels (MPPs) have been studied extensively as sound absorption systems to increase the absorption performance of single-layer MPPs. However, existing proposed models indicate that there is still room for improvement regarding the frequency bands of absorption for the double-layer MPP. This study presents a double-layer MPP formed with two single MPPs with inhomogeneous perforation backed by multiple cavities of varying depths. The theoretical formulation is developed using the electrical equivalent circuit method to calculate the absorption coefficient under a normal incident sound. The simulation results show that the proposed model can produce absorption coefficient with wider absorption bandwidth compared w
... Show More
Abstract:
The models of time series often suffer from the problem of the existence of outliers that accompany the data collection process for many reasons, their existence may have a significant impact on the estimation of the parameters of the studied model. Access to highly efficient estimators is one of the most important stages of statistical analysis, And it is therefore important to choose the appropriate methods to obtain good estimators. The aim of this research is to compare the ordinary estimators and the robust estimators of the estimation of the parameters of
... Show MoreThe photonconductor detectors CdSe:Cu was fabricated as a thin film of (1 μm) in thickness using vacuum evaporation technique. doping with copper was made using vacuum annealing at 350oC under argon atmosphere . The spectral responsivity and spectral detectivity of the detector were determined as a function of incident wavelength on the sample. A remarkable improvement in performance was absorbed for the specimen, which doping with (1-5 wt%) Cu.
The spectral response increases with increasing of wavelength for incident radiation to maximum value, after that , it reduced sharply . There is a shifting for peak responsivity indirect of higher wavelength. The detectivity was increased with doping but its decreased as the concentration in
The presence of a single complex adaptive weight in each element channel of an adaptive array antenna is sufficient for processing of narrowband signals. The ability of an adaptive array antenna to null interference deteriorates rapidly as the interference bandwidth increases. The performance of narrowband adaptive array antenna with LMCV Beamforming algorithm is examined. The interaction effects between received signal angle of arrival and array parameters like the interelement spacing and the number of array element and the received signal bandwidth were studied. The output Signal to Interference plus Noise Ratio (SINR) and Interference to Noise Ratio (INR) are used as performance parameters for evaluation of these effects. It is found
... Show MoreThe present study aimed to examine the effect of endosulfan insecticide on some molecular and biochemical parameters in white mice. Thirty mice were separated randomly into three groups for treatment with endosulfan. One group (G1) served as the control, while the other two groups received intraperitoneal injections of endosulfan G2 (3 mg/kg) and G3 (17 mg/kg) twice a week for 21 and 45 days, respectively. A biochemical study by measuring liver function parameters, including (alanine aminotransferase (ALT) and aspartate aminotransferase (AST)) and kidney function parameters, including (Blood Urea and Creatinine) and malondialdehyde (MDA), catalase activity (CAT). This study also tested DNA damage by comet assay (normal%, low%, med
... Show MoreThere is a growing need for up-to-date data for rapid decision making in the modern digital age. Recently, the need for high-resolution topographic maps is highly demanding by most mapping clients. With the maturing automatic structure from mobile and multi-view stereoscopy software, small organizations and individuals now have the ability to make their own surveys based on mobile mapping devices. This study looks at how feasible using low-cost Unmanned Aerial Vehicle (UAV) as a mobile mapping device for photogrammetric topographical surveys. It is showing the impact of different UAV flight settings and parameters on the accuracy of mapping products. An automatic scenario for photogra
In this paper ,the problem of point estimation for the two parameters of logistic distribution has been investigated using simulation technique. The rank sampling set estimator method which is one of the Non_Baysian procedure and Lindley approximation estimator method which is one of the Baysian method were used to estimate the parameters of logistic distribution. Comparing between these two mentioned methods by employing mean square error measure and mean absolute percentage error measure .At last simulation technique used to generate many number of samples sizes to compare between these methods.