In this work, wide band range photo detector operating in UV, Visible and IR was fabricated using carbon nanotubes (MWCNTs, SWCNTs) decorated with silver nanoparticles (Ag NPs). Silicon was used as a substrate to deposited CNTs/Ag NPs by the drop casting technique. Polyamide nylon polymer was used to coat CNTs/Ag NPs to enhance the photo-response of the detector. The electro-exploding wire technology was used to synthesize Ag NPs. Good dispersion of silver NPs achieved by a simple chemistry process on the surface of CNTs. The optical, structure and electrical characteristic of CNTs decorated with Ag NPs were characterized by X-Ray diffraction and Field Emission Scanning Electron Microscopy. X-ray diffraction patterns of Ag NPs exhibited 2θ values (38.1°,44.3°) corresponding to the Ag nanocrystal, while the XRD pattern of MWCNTs and SWCNTs /Ag NPs peaks appeared at 2θ = 26.2° corresponding to the (002) and at 2theta=44° which corresponds with miller indices (100) for CNTs and (200) for Ag NPs. The optical properties measured by UV-Vis. Spectroscopy. Broad and strong surface plasmon resonance (SPR) peak was detected at 420 nm, for Ag NPs. The absorption of CNTs/Ag NPs increased significantly from UV to near IR region (300-1000 nm). Ag NPs decorated CNTs without any impurities, according to field mission scanning electron microscopy examination, with typical particle sizes of (50-80nm) for Ag-NPs, 44nm for MWCNTs/Ag-NPs, and 30nm for SWCNTs/Ag NPs. ֹThe I-V characteristics at forward bias voltage (0.5-10) volt were studied. The figure of merits (responsivity, photocurrent gain, NEP and detectivity) after coating with polymer of the detector were measured in the dark and after illumination with UV LED (365 nm), Tungsten lamp (500-800 nm) and Laser diode (808 nm).
Background: Acute abdominal pain classically refers to pain within the abdomen that has been present for less than 7 days from the time of presentation. The use of CT scan in the evaluation of acute abdominal pain has increased to a large extent due to high accuracy of CT in the diagnosis of specific diseases like appendicitis and diverticulitis, especially with the use of multidetector CT scanners. It has been shown that the use of intravenous contrast media increases the diagnostic accuracy of CT scan examination, with a positive predictive value of 95% in the cases of acute appendicitis. The accuracy of CT scan imaging in patients with acute abdominal pain was not affected by the lack of entral contrast material.
Objectives: To eva
Background: Polyetheretherketone (PEEK) is a promising implant material due to its superior biomechanical strength. However, due to its hydrophobic nature and lack of cellular adhesion properties, it has poor integration with bone tissue. Methods: A fractional CO2 laser was used with various parameters for surface texturing of PEEK substrate to enhance its surface properties. An optical microscope and field-emission scanning electron microscope (FESEM) were used to examine the surface morphology of untextured and laser-textured samples. Energy dispersive X-ray spectroscopy (EDX) was performed to determine the effect of the laser on the microstructure of PEEK. Surface microroughness, atomic force microscopy (AFM), and wettability were invest
... Show MoreIn this work, silver (Ag) self-metallization on a polyimide (PI) film was prepared through autocatalytic plating. PI films were prepared through the solution casting method, followed by etching with potassium hydroxide (KOH) solution, sensitization with tin chloride (SnCl2), and the use of palladium chloride (PdCl2) to activate the surface of PI. Energy-dispersive X-ray analysis (EDX) showed the highest peak in the (Ag) region and confirmed the presence of AgNPs. The diffraction peaks at 2θ = 38.2°, 44.5°, 64.6°, and 78.2° represented the 111, 200, 220, and 311 planes of Ag, respectively. The FT–IR an
... Show MorePolymer electrolytes systems compose of (PEO+KI+I2) and (PEO+RbI+I2) with different concentration, and a fixed amount of ethylene carbonate (EC) and propylene carbonate (PC) over temperatures range 293-343 K prepared by solution cast me
... Show MoreA filed experiment was carried out at one of the private farms at Al-Suwaira District, Wasit Governorate during the spring season 2021, in order to evaluate the effect of adding Fulyzme plus (biofertilizer) and the foliar application of green tea extract (organic nutrient) on growth and yield of pepper plant cv. California wonder. A factorial experiment (43) was carried out using RCBD Design with three replicates. The Fulyzme plus treatment was applied with four concentrations (0, 10, 20. and 30 g. L-1). The foliar application of green tea extract was applied with three concentrations which were 0, 2 and 4 ml. L-1. Results revealed significant effects of Fulyzme plus at 30 g. L-1 and the foliar application of green tea extract at
... Show MoreThe 3D electro-Fenton technique is, due to its high efficiency, one of the technologies suggested to eliminate organic pollutants in wastewater. The type of particle electrode used in the 3D electro-Fenton process is one of the most crucial variables because of its effect on the formation of reactive species and the source of iron ions. The electrolytic cell in the current study consisted of graphite as an anode, carbon fiber (CF) modified with graphene as a cathode, and iron foam particles as a third electrode. A response surface methodology (RSM) approach was used to optimize the 3D electro-Fenton process. The RSM results revealed that the quadratic model has a high R2 of 99.05 %. At 4 g L-1 iron foam particles, time of 5 h, and
... Show MoreIn this study, the gamma ray shielding properties of shields prepared from polyvinyl alcohol as a base material reinforced with barium sulfate nanoparticles at different reinforcement ratios (5,15,25,35,45 %) and thickness 1 cm were studied. To determine the acceptability of these shields for use in gamma ray protection, some parameters including linear attenuation coefficient (μ), mean free path (λ), and half value layer (HVL) were determined using133Ba, 22Na, 137Cs, and 60Co radioactive sources that produced gamma rays with energies of (356, 662, 1173, 1275 and 1332 KeV). The (NaI (Tl)) gamma system was employed for this purpose. The fabricated shields' effective atomic
... Show More