Preferred Language
Articles
/
ijp-608
Effect of Transition Metal Dopant on the Electrical Properties of ZnO-TiO2 Films Prepared by PLD Technique
...Show More Authors

In this article, the influence of group nano transition metal oxides such as {(MnO2), (Fe2O3) and (CuO)} thin films on the (ZnO-TiO2) electric characteristics have been analyzed. The prepared films deposited on glass substrate laser Nd-YAG with wavelength (ℷ =1064 nm) ,energy of (800mJ) and number of shots (400). The density of the film was found to be (200 nm) at room temperature (RT) and annealing temperature (573K).Using DC Conductivity and Hall Effect, we obtained the electrical properties of the films. The DC Conductivity shows that that the activation energies decrease while the σRT at annealing temperature with different elements increases the formation of mixed oxides. The Hall effect, the electrical properties of the films were described. It was observed through Hall Effect measurements that the films loaded vectors of the shape N and the type P.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Dec 30 2018
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Removal Of Dissolved Cadmium Ions from Contaminated Wastewater using Raw Scrap Zero-Valent Iron And Zero Valent Aluminum as Locally Available and Inexpensive Sorbent Wastes
...Show More Authors

The current study was to examine the reliability and effectiveness of using most abundant, inexpensive waste in the form of scrap raw zero valent aluminum ZVAI and zero valent iron ZVI for the capture, retard, and removal of one of the most serious and hazardous heavy metals cadmium dissolved in water. Batch tests were conducted to examine contact time (0-250) min, sorbent dose (0.25-1 g ZVAI/100 mL and 2-8 g ZVI/100 mL), initial pH (3-6), pollutant concentration of 50mg/L initially, and speed of agitation (0-250) rpm . Maximum contaminant removal efficiency corresponding to (90 %) for cadmium at 250 min contact time, 1g ZVAI/ 6g ZVI sorbent mass ratio, pH 5.5, pollutant concentration of 50 mg/L initially, and 250 rpm agitation speed wer

... Show More
View Publication Preview PDF
Crossref (11)
Crossref
Publication Date
Wed Jan 01 2025
Journal Name
Open Veterinary Journal
<b>Bacteriological and histopathological study of <i>Raoultella planticola</i> in local rabbits with respiratory distress</b>
...Show More Authors

Introduction: The bacteriological and histopathological study of Raoultella planticola in local rabbits is not presented in previous research. There is no specific information about studying this bacterium in local rabbits. Hypothesis: The present study was based on Bacteriological and Histopathological changes in the trachea and lung of local rabbits after Samples were collected from 50 unhealthy animals that appear to be suffering from respiratory signs. Aim: To study the bacteria that were isolated for the first time from sheep suffering from respiratory infections, and diagnose them through Vitk2. Methods: We injected them into a group of local rabbits and studied the histopathological changes in the trachea and lungs. d

... Show More
View Publication
Scopus Crossref
Publication Date
Tue Mar 25 2025
Journal Name
Indonesian Journal Of Chemistry
Synthesis, Characterization, and Antioxidant Activity of Cr(III), Mn(II), Fe(III), Co(II) and Ni(II) Complexes with Mixed Azo Dye and Bipyridyl Ligands
...Show More Authors

Mixed ligands reaction of [2-[(3-hydroxyphenyl)diazinyl]-1,2-benzothiazol-3(2H)-one-1,1-dioxide] (H2L, primary ligand) and bipyridyl (secondary ligand) with salts of Cr(III), Mn(II), Fe(III), Co(II) and Ni(II) was performed. A series of air-stable complexes with distinctive octahedral moieties was created by equal molar ratio (1:1:1). The formation of these compounds was verified using detecting analysis techniques incorporating mass spectra, which validated the achieved geometries. Fourier transform infrared (FTIR) analysis demonstrated how the ligands (H2L and bipyridyl) are chelated as tridentate (ONO) and bidentate (NN) groups, respectively and the coordination with the metal ions. Thermal decomposition studies using pyrolysis (

... Show More
View Publication
Scopus (4)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Sat Jun 01 2019
Journal Name
Acta Chromatographica
A simple stability-indicating HPLC method for simultaneous analysis of paracetamol and caffeine and its application to determinations in fixed-dose combination tablet dosage form
...Show More Authors

A simple, economic, rapid, reliable, and stability-indicating high-performance liquid chromatography (HPLC) method has been developed and validated for the simultaneous determination of paracetamol (PCM) and caffeine (CF) in solid dosage form. The chromatographic separations were achieved with a Waters Symmetry® C18 column (5 μm, 4.6 × 150 mm), using a mixture of methanol and water (40:60, v/v) as a mobile phase, under isocratic elution mode with a flow rate of 0.8 mL/min, and ultraviolet (UV) detection was set at 264 nm. The oven temperature for the column was set and maintained at 35 °C. The method was validated according to International Conference on Harmonization (ICH) guidelines, and it demonstrated excellent linearity, wi

... Show More
View Publication
Scopus (32)
Crossref (26)
Scopus Clarivate Crossref
Publication Date
Mon Jul 01 2024
Journal Name
Journal Of Water Process Engineering
Polypyrrole-coated zinc/nickel oxide nanocomposites as adsorbents for enhanced removal of Pb(II) in aqueous solution and wastewater: An isothermal, kinetic, and thermodynamic study
...Show More Authors

One common heavy metal that is extremely harmful to the kidneys, reproductive system, and nervous system of humans is lead (Pb). This study aimed to investigate the effectiveness of a novel nanocomposite adsorbent, synthesised from polypyrrole, zinc oxide, and nickel (PPy/ZnO-NiO), in eliminating Pb(II) ions from a waterbased solution. This adsorbent offers excellent metal selectivity, environmental stability, ease of manufacture, and reusability. Several techniques, namely XRD, FTIR, TGA, SEM, TEM, EDX, and BET, were employed to characterize the synthesised nanocomposite adsorbent. The study examined the impact of multiple factors influencing the adsorption process, including pH, temperature, contact period, metal ion concentration, and ad

... Show More
Scopus (40)
Crossref (38)
Scopus Crossref
Publication Date
Fri Jul 01 2022
Journal Name
Sustainable Materials And Technologies
Green approach for fabrication of graphene from polyethylene terephthalate (PET) bottle waste as reactive material for dyes removal from aqueous solution: Batch and continuous study
...Show More Authors

Scopus (49)
Crossref (13)
Scopus Clarivate Crossref
Publication Date
Fri Jun 03 2016
Journal Name
Al- Kindy College Medical Journal
Laser Diode Enhances Autologous Cartilage Graft's Expansibility
...Show More Authors

Background: Cartilage forms most of the temporary skeleton of the embryo and provides a model in which most bones develop Objective: Using laser therapy to enhance autologous cartilage grafts expansibility and to analyze whether this "enhancement" results in reduced rates of cartilage resorption and greater preservation of normal architectural features compared with "unenhanced" grafts. Type of the study: Cross sectional study. Methods: 24 New Zealand rabbits were divided into two groups (control and treated with 904nm, 10mW diode laser). Auricular cartilage segments measuring 1 cm2 were harvested from both ears of each rabbit, and were implanted in to the subcutaneous region of the left flank. 3 rabbits from each group were anaesthetized a

... Show More
View Publication Preview PDF
Publication Date
Sun Jan 01 2017
Journal Name
Biomedical & Pharmacology Journal
Diode Laser Versus Scalpel Gingivectomy
...Show More Authors

Different methods can be used to remove tissue during gingivectomy and produce a good gingival margin, the most common is the conventional gingivectomy which is done by the use of scalpel, now a day’s Laser is widely spread and can be used to perform surgeries. Materials and methods: 50 patients divided into two equal groups, Group 1 gingivectomy was done by Diode Laser, Group 2 gingivectomy was done by scalpel, plaque and gingival index were measured at 1st, 2nd and 3rd visit, swab were taken and sent foe detecting bacterial growth and biopsy were taken for histopathological examination. Group 1 show no significant differences in plaque and gingival means between the visits, the bacteriological examination showed no growth of bact

... Show More
Publication Date
Thu Jun 30 2016
Journal Name
Al-kindy College Medical Journal
Laser Diode Enhances Autologous Cartilage Graft's Expansibility
...Show More Authors

Background: Cartilage forms most of the temporary skeleton of the embryo and provides a model in which most bones developObjective: Using laser therapy to enhance autologous cartilage grafts expansibility and to analyze whether this "enhancement" results in reduced rates of cartilage resorption and greater preservation of normal architectural features compared with "unenhanced" grafts. Type of the study: Cross sectional study.Methods: 24 New Zealand rabbits were divided into two groups (control and treated with 904nm, 10mW diode laser). Auricular cartilage segments measuring 1 cm2 were harvested from both ears of each rabbit, and were implanted in to the subcutaneous region of the left flank. 3 rabbits from each group were anaesthetized

... Show More
View Publication Preview PDF
Publication Date
Mon Nov 01 2010
Journal Name
Iraqi Journal Of Physics
Night Vision monitor for IR laser spot size Identification
...Show More Authors

The aim of this research is to design and construct a
semiconductor laser range finder operating in the near infrared range
for ranging and designation. The main part of the range finder is the
transmitter which is a semiconductor laser type GaAs of wavelength
0.904 μm with a beam expander and the receiver; a silicon pin
detector biased to approve the fast response time with it's collecting
optics. The transmitters pulse width was 200ns at a threshold current
of 10 Ampere and maximum operating current of 38 Ampere. The
repetition rate was set at 660Hz and the maximum operating output
power was around 1 watt. The divergence of the beam was 0.268o
the efficiency of the laser was 0.03% at a duty cycle of 1.32x

... Show More
View Publication Preview PDF