Photonic Crystal Fiber Interferometers (PCFIs) are widely used for sensing applications. This work presents the fabrication and study the characterization of a relative humidity sensor based on a polymer-infiltrated photonic crystal fiber that operates in a Mach- Zehnder Interferometer (MZI) reflection mode. The fabrication of the sensor only involves splicing and cleaving Photonic Crystal Fiber (PCF) with Single Mode Fiber (SMF). A stub of (LMA-10) PCF spliced to SMF (Corning-28). In the splice regions. The PCFI sensor operation based on the adsorption and desorption of water vapour at the silica-air interface within the PCF. The sensor shows a high sensitivity to RH variations from (27% RH - 95% RH), with a change in its reflected power and the position of the interference peaks is found to be shifted that the interference pattern with a 100 nm span can be observed with high humidity sensitivity of (8.49 pm / %RH) is achieved with compact (4mm) PCF length . The sensor has the advantages for suitable for monitoring humidity in microenvironments. The repeatability, long-term stability, measurement accuracy. Wide humidity range. The response time of the sensor is found to be 1.4 sec for a change in RH of 50 %RH. The fast response time suggests that the sensor can potentially be used as a human breath rate monitor in a clinical situation.
The research is trying to identify the investment portfolio risks of the insurance company and their impact, on the Profitability ratios of the company, and whether the company's scientific methods followed in the measurement of these risks, and conducted research in the National Insurance Company. by relying on its annual budget as well as the annual reports, The search dealing with these data in theoretical and practical major premise to statistically significant between to investment portfolio risk and financial performance correlation and reach a set of conclusions and recommendations which are the following.
investments include many ri
... Show MoreA real method of predication brake pad wear ,could lead to substantiol economies of time and money. This paper describes how such a procedure has been used and gives the results to establish is reliability by comparing the predicted wear with that which actually occurs in an existing service. The experimental work was carried out on three different commercial samples ,tested under different operation conditions (speed,load,time...etc)using a test ring especially modified for this purpose. Abrasive wear is mainly studied , since it is the type of wear that takes place in such arrangements. Samples wear tested in presences of sand or mud between the mating surfaces under different operational conditions of speed, load and braking time .Mec
... Show MoreThis paper proposed a new method for network self-fault management (NSFM) based on two technologies: intelligent agent to automate fault management tasks, and Windows Management Instrumentations (WMI) to identify the fault faster when resources are independent (different type of devices). The proposed network self-fault management reduced the load of network traffic by reducing the request and response between the server and client, which achieves less downtime for each node in state of fault occurring in the client. The performance of the proposed system is measured by three measures: efficiency, availability, and reliability. A high efficiency average is obtained depending on the faults occurred in the system which reaches to
... Show More