Preferred Language
Articles
/
ijp-437
Investigate Salts type and concentration on the conductivity of Polymer Electrolyte
...Show More Authors

Polymer electrolytes systems compose of (PEO+KI+I2) and (PEO+RbI+I2) with different concentration, and a fixed amount of ethylene carbonate (EC) and propylene carbonate (PC) over temperatures range 293-343 K prepared by solution cast method. The conductivity and dielectric constant of the gel electrolytes were studied. The conductivity of the electrolytes Ss & Hs increases steadily with increased concentration of salt KI and RbI. The higher value of conductivity of (4.7 10-3 @ RT S.cm-1) for S5 electrolyte which contains (KI 50%). Whereas the maximum amount of conductivity of (5.4 10³ @RT S.cm⁻ˡ) for H5 electrolyte which contains (RbI 50%) the ionic conductivity depends on the ionic radii of the migrating species (cation K⁺, Rb⁺) effect on it. As the temperature increase, the number of free ions also increases, thus increases the diffusion of ions through their free volume of the polymer. The dielectric constant decrease at higher frequencies due to the inability of dipoles to align quickly with the change of applied field. The dielectric constant proportional positively with variation temperature causes an increase in the dielectric constant. The higher the value of (εr), the better is the electrical conductivity.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Aug 22 2023
Journal Name
Advances In Structural Engineering
Experimental and finite element analysis of reinforced concrete multi-cell box girders retrofitted with carbon fiber reinforced polymer strips under torsion
...Show More Authors

This study expands the state of the art in studies that assess torsional retrofit of reinforced concrete (RC) multi-cell box girders with carbon fiber reinforced polymer (CFRP) strips. The torsional behavior of non-damaged and pre-damaged RC multi-cell box girder specimens externally retrofitted by CFRP strips was investigated through a series of laboratory experiments. It was found that retrofitting the pre-damaged specimens with CFRP strips increased the ultimate torsional capacity by more than 50% as compared to the un-damaged specimens subjected to equivalent retrofitting. This indicated that the retrofit has been less effective for the girder specimen that did not develop distortion beforehand as a result of pre-loading. From

... Show More
View Publication
Scopus (16)
Crossref (14)
Scopus Clarivate Crossref
Publication Date
Sun Dec 01 2024
Journal Name
Energy Storage
Comprehensive Study of PAN-NaBF4 Solid Polymer Electrolytes: Insights Into Optical, Structural, Thermal, Electrical, and Electrochemical Properties for Sodium-Ion Batteries
...Show More Authors

This research explores the use of solid polymer electrolytes (SPEs) as a conductive medium for sodium ions in sodium‐ion batteries, presenting a possible alternative to traditional lithium‐ion battery technology. The researchers prepare SPEs with varying molecular weight ratios of polyacrylonitrile (PAN) and sodium tetrafluoroborate (NaBF4) using a solution casting method with dimethyl formamide as the solvent. Through optical absorbance measurements, we identified the PAN:NaBF4 (80:20) SPE composition as having the lowest energy band gap value (4.48 eV). This composition also exhibits high thermal stability based on thermogravimetric analysis results. Electrochemical impedance spectroscopy re

... Show More
View Publication
Scopus (10)
Scopus
Publication Date
Tue Aug 22 2023
Journal Name
Advances In Structural Engineering
Experimental and finite element analysis of reinforced concrete multi-cell box girders retrofitted with carbon fiber reinforced polymer strips under torsion
...Show More Authors

This study expands the state of the art in studies that assess torsional retrofit of reinforced concrete (RC) multi-cell box girders with carbon fiber reinforced polymer (CFRP) strips. The torsional behavior of non-damaged and pre-damaged RC multi-cell box girder specimens externally retrofitted by CFRP strips was investigated through a series of laboratory experiments. It was found that retrofitting the pre-damaged specimens with CFRP strips increased the ultimate torsional capacity by more than 50% as compared to the un-damaged specimens subjected to equivalent retrofitting. This indicated that the retrofit has been less effective for the girder specimen that did not develop distortion beforehand as a result of pre-loading. From

... Show More
Scopus (16)
Crossref (14)
Scopus Clarivate Crossref
Publication Date
Fri Nov 11 2011
Journal Name
Journal Of The European Optical Society: Rapid Publications
Transition from amplified spontaneous emission to laser action in disordered media of R6G dye and TiO2 nanoparticles doped with PMMA polymer
...Show More Authors

View Publication
Scopus (5)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Fri Sep 25 2026
Journal Name
Analytical Methods In Environmental Chemistry Journal
Electrochemical Analysis: Highly Selective Determination of Tenoxicam in Pharmaceutical and Environmental Samples Using a Molecularly Imprinted Polymer-Based Potentiometric Electrochemical Sensor
...Show More Authors

A highly selective potentiometric method for the determination of tenoxicam (TEX) was developed based on molecularly imprinted polymer (MIP) membrane electrodes. This s‌ tudy contributes to the field of analytical chemis‌ try by designing advanced electrochemical sensors for pharmaceutical analysis. The tenoxicam-imprinted polymers (TEX-MIPs) were synthesized using tenoxicam as the template molecule, allyl chloride as the functional monomer, trimethylolpropane triacrylate (TMPTA) as the cross-linking agent, and benzoyl peroxide (BP) as the radical initiator. Poly(vinyl chloride) (PVC)-based membranes were fabricated incorporating various plas‌ ticizers, namely oleic acid (O.A), paraffin (PRF), tri-butyl phosphate (TBP), and di-butyl s

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Sat Jan 01 2011
Journal Name
Iraqi J Pharm Sci,
Serum Level Profile and Pharmacokinetic Parameters of Single Oral Dose of Metronidazole in Type II Diabetic Patients
...Show More Authors

Many pathophysiological processes can affect the pharmacokinetic properties of drugs in people with diabetes. The present study was deigned to evaluate the influence of diabetes mellitus (DM) on the pharmacokinetic parameters of metronidazole administered as single oral dose. Twelve healthy volunteers and twelve diabetic patients were enrolled in the present study. On day 1, a single oral dose of metronidazole 500 mg was administered orally to all participants at 9:00 am after a 10-hour fasting. Over the following 48 hours, blood samples were taken at frequent intervals and serum metronidazole concentrations were measured by a high-performance liquid chromatography method for assessment of pharmacokinetics of metronidazole. The data

... Show More
Publication Date
Sun Dec 30 2012
Journal Name
Al-kindy College Medical Journal
Initial Recognition and Prophecy of Diabetic Nephropathy in Type I Diabetes in a Sample of Iraqi Patients
...Show More Authors

Back ground: Diabetic nephropathy is rapidly becoming the leading cause of end-stage renal disease (ESRD). The onset and course of DN can be ameliorated to a very significant degree if intervention institutes at a point very early in the course of the development of this complication.
Objective: The aim of this study was to characterize risk factors associated with nephropathy in type I diabetes and construct a module for early prediction of diabetic nephropathy (DN) by analyzing their risk factors.
Methods: Case control design of 400 patients with type I diabetes mellitus (IDDM), aged 19-45 years. The cases were 200 diabetic patients with overt protein urea while the controls were 200 diabetic patients with no protein urea or micr

... Show More
View Publication Preview PDF
Publication Date
Wed Mar 29 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Serum Level Profile and Pharmacokinetic Parameters of Single Oral Dose of Metronidazole in Type II Diabetic Patients
...Show More Authors

Many pathophysiological processes can affect the pharmacokinetic properties of drugs in people with diabetes. The present study was deigned to evaluate the influence of diabetes mellitus (DM) on the pharmacokinetic parameters of metronidazole administered as single oral dose. Twelve healthy volunteers and twelve diabetic patients were enrolled in the present study. On day 1, a single oral dose of metronidazole 500 mg was administered orally to all participants at 9:00 am after a 10-hour fasting. Over the following 48 hours, blood samples were taken at frequent intervals and serum metronidazole concentrations were measured by a high-performance liquid chromatography method for assessment of pharmacokinetics of metronid

... Show More
View Publication Preview PDF
Crossref (7)
Crossref
Publication Date
Sat Nov 30 2019
Journal Name
Journal Of Engineering And Applied Sciences
Study the Effect of Heat Treatment and Pressure on Some Electrical Properties of Nano Polycarbonate
...Show More Authors

In the present research, the electrical properties which included the ac-conductivity (σac), loss tangent of dielectric (tan δ) and real dielectric constant (ε’) are studied for nano polycarbonate in different pressures and frequencies as a function of temperature these properties were studied at selective temperature gradients which are (RT-50-100-150-250)°C. The results of the study showed that the values of dielectric constant and dissipation factor increase with increasing pressure and temperature and decreases by increasing frequency. And the results of electrical conductivity showed that it increases with increasing temperature, pressure and frequency.

View Publication Preview PDF
Scopus
Publication Date
Sun Dec 03 2017
Journal Name
Baghdad Science Journal
Measurement of Indoor Radon Gas Concentration in same Region of Baghdad Governorate Using CR-39 Nuclear Track Detector
...Show More Authors

In this research the activity of radon gas in air in Baghad governorate,Iraq, using “alpha-emitters track registration (CR-39) track detector were measured. This measurement was done for selected areas from Baghdad Governorate, The results obtained shows that the highest average concentrations for Rn-222 is (179.077 Bq/m^3) which was recorded within Al-Shaaib city and less average concentrations was (15.79 Bq/m^3) in the nearby residential area of Baghdad International Airport and the overall average concentrations is (86.508 Bq/m^3) for these regions. Then the radon concentration was measured annual effective dose calculated from radon concentration and found in range from 0.4031 mSv/y to 4.5179 mSv /y with an average value of 2.1824 m

... Show More
View Publication Preview PDF
Scopus (4)
Crossref (1)
Scopus Crossref