Preferred Language
Articles
/
ijp-415
Cu Nanoparticles preparation by Laser Ablation in Liquid Phase method (LALP)
...Show More Authors

Nanoparticle has pulled in expanding consideration with the developing enthusiasm for nanotechnology which hold potential as essential segments for development applications. In the present work, a copper nanoparticle is manufactured as a suspension in distilled water by beating a bulk copper target with laser source (532 nm wavelength, 10 ns pulse duration and 10 Hz repletion rate) via method. UV- visible absorption spectra and AFM analysis has been done to observe the effect of repetition rate for the pulsation of laser. Copper nanoparticles (Cu-NPs) were successfully synthesized with green color. The Cu- NPs have very high purity because the preparation was managed in aqueous media to eliminate ambient contaminations.  Absorption spectrum shows peaks at 450 nm- 700 nm µm due to the generation of Cu-NPs.  

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Jan 10 2024
Journal Name
Journal Of Optics
Pulsed laser deposition of Pd/WO3 nanoparticles on Si nanostructure for highly sensitive room-temperature gas sensors
...Show More Authors

View Publication
Scopus (8)
Crossref (9)
Scopus Clarivate Crossref
Publication Date
Fri Nov 11 2011
Journal Name
Journal Of The European Optical Society: Rapid Publications
Transition from amplified spontaneous emission to laser action in disordered media of R6G dye and TiO2 nanoparticles doped with PMMA polymer
...Show More Authors

View Publication
Scopus (4)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Sun Jun 21 2020
Journal Name
Baghdad Science Journal
Spectrophotometer Determination of Cefixime in pure form and pharmaceutical preparation by Using Cloud point Extraction
...Show More Authors

Two simple methods spectrophotometric were suggested for the determination of Cefixime (CFX) in pure form and pharmaceutical preparation. The first method is based without cloud point (CPE) on diazotization of the Cefixime drug by sodium nitrite at 5Cº followed by coupling with ortho nitro phenol in basic medium to form orange colour. The product was stabilized and measured 400 nm. Beer’s law was obeyed in the concentration range of (10-160) μg∙mL-1 Sandell’s sensitivity was 0.0888μg∙cm-1, the detection limit was 0.07896μg∙mL-1, and the limit of Quantitation was 0.085389μg∙mL-1.The second method was cloud point extraction (CPE) with using  Trtion X-114 as surfactant. Beer

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Sat Mar 01 2014
Journal Name
Eeng. &tech.journal
Preparation and Characterization of High Quality SnO2 Films Grown by (HPCVD)
...Show More Authors

ABSTRACT: In this research SnO2 thin films have been prepared by using hot plate atmospheric pressure chemical vapor deposition (HPCVD) on glass and Si (n-type) substrates at various temperatures. Optical properties have been measured by UV-VIS spectrophotometer, maximum transmittance about (94%) at 400 0C. Structure properties have been studied by using X-ray diffraction (XRD) , its shows that all films have a crystalline structure in nature and by increasing growth temperature from(350-500) 0C diffraction peaks becomes sharper and grain size has been change. Atomic force microscopy (AFM) uses to analyze the morphology of the Tine Oxides surface structure. Roughness & Root mean square for different temperature have been investigated. The r

... Show More
Preview PDF
Publication Date
Sun Mar 02 2008
Journal Name
Baghdad Science Journal
Pre-column dervatization of amino acids from nigella sativa L seed hydrolysates by reversed phase HPLC
...Show More Authors

A rapid and sensitive method for analysis of amino acid hydrolysates of nigella sativa L seed has been developed using O-phthaldialehyde(OPA ) as a pre-column derivatizing agent. OPA reagents in the presence of mercaptoethanol react rapidly with primary amino acids ( less than 60 sec.) to form isindole derivatives which easily separated with good selectivity on ODS column. Resolution of amino acid derivatives is carried out with a methanol gradient in 0.01 maqueous sodium acetate. pH 7.1 . The quantitation of amino acid derivatives is reproducible within an average relative deviation of + 1.4% the linearity for most amino acids were more than 0.9993 with detection limit of 0.2 ppm. 15 amino acid were detected in the analysis of

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Sun Dec 07 2008
Journal Name
Baghdad Science Journal
Improvement of the monochrome image hologram by using a random phase and increasing number of Samples
...Show More Authors

This paper present a study about effect of the random phase and expansion of the scale sampling factors to improve the monochrome image hologram and compared it with previous produced others. Matlab software is used to synthesize and reconstruction hologram.

View Publication Preview PDF
Crossref
Publication Date
Sat Jun 30 2007
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Corrosion Inhibition of Carbon Steel under Two Phase Flow (Water-Petroleum) Simulated by Turbulently Agitated System
...Show More Authors

The corrosion of carbon steel in single phase (water with 0.1N NaCl ) and two immiscible phases (kerosene-water) using turbulently agitated system is investigated. The experiments are carried out for Reynolds number (Re) range of 38000 to 95000 corresponding  to rotational velocities from 600 to 1400 rpm using circular disk turbine agitator at 40 0C. In two-phase system test runs are carried out in aqueous phase (water) concentrations of 1 % vol., 5 % vol., 8% vol., and 16% vol. mixed with kerosene at various Re. The effect of Reynolds number (Re), percent of dispersed phase, dispersed drops diameter, and number of drops per unit volume on the corrosion rate is investigated and discussed. Test runs are carried out using two types of

... Show More
View Publication Preview PDF
Publication Date
Tue Jun 09 2026
Journal Name
Optical Review
Preparation and characterization of ZnO: Ga2O3 thin film via pulsed laser deposition for NO2 and H2S gas sensing application
...Show More Authors

In this study, thin film of pure zinc oxide (ZnO) and ZnO doped with Ga2O3 films with different concentrations (0, 0.03, 0.05, 0.07 and 0.09)wt% were prepared by pulsed laser deposition. The powder mixture was then sintered in a furnace at 1273 K for 5 h. The resulting powders were thoroughly ground and then pressed using a special press to form discs with a diameter of 1 cm and a thickness of 0.5 cm. The deposition was carried out under a vacuum of 2.5×10−2 mbar on various substrates, including glass for AFM measurements and n-type crystalline silicon wafers for the gas sensor. AFM results revealed a progressive increase in both grain size and roughness with moderate doping and irregularity at high doping levels. Gas-sensing meas

... Show More
View Publication
Scopus Crossref
Publication Date
Wed Feb 01 2023
Journal Name
Journal Of Ecological Engineering
Chlorpyrifos Removal from Aqueous Solutions by Emulsion Liquid Membrane – Stability, Extraction, and Stripping Studies
...Show More Authors

Crossref (5)
Crossref
Publication Date
Tue Dec 01 2015
Journal Name
Second Engineering Scientific Conference
SEPARATION OF ALKALOIDS FROM PLANTS BY BULK LIQUID MEMBRANE TECHNIQUE USING ROTATING DISCS CONTACTOR
...Show More Authors

This paper describes the transport of Alkaloids through Rotating Discs Contactor (RDC) using n-decane as a liquid membrane. The transport of Pelletierine Alkaloid from a source phase through bulk liquid membrane to the receiving phase has been investigated. The general behaviour of Pertraction process indicates that% Extraction of pelletierine Alkaloid increased with increase in the number of stages and the agitation speed but high agitation speed was not favoured due to the increased risk of droplet formation during the operation. The pH of source and receiving phases were also investigated. The effect of organic solvent membrane on the extraction of Pelletierine was evaluated using ndecane, n-hexane and methyl cyclohexane. The results sho

... Show More