Preferred Language
Articles
/
ijp-365
Synthesis of polyynes by laser ablation of graphite in ethanol
...Show More Authors

In this work  Polyynes was synthesized by pulse laser ablation of graphite target in ethanol solution. UV-Visible Spectrophotometer, Fourier Transform Infrared Spectroscopy (FTIR) and Transmission electron microscopy (TEM) were used to study the optical absorption, chemical bonding, particle size and the morphology.  UV absorption peaks coincide with the electronic transitions corresponding to linear hydrogen – capped polyyne (Cn+1H2), the absorption peaks intensity increased when the polyynes were produced at different laser energies and the formation rats of polyynes increased with the increasing of laser pulse number. The FTIR absorption peak at 2368.4 cm-1, 1640.0 cm-1 and 1276.8 cm-1 stretching vibration bond, were refer to the C ≡ C, C = C and C-C, respectively. A bond suggests the formation carbon nanoparticles suspend in this solvent and the TEM show the formation of spherical nanoparticles with size ranges from (1.2 to 105.9 nm) and aggregation of the carbon nanoparticles.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Jan 01 2022
Journal Name
Pharmacia
Synthesis, docking study, and structureactivity relationship of novel niflumic acid derivatives acting as anticancer agents by inhibiting VEGFR or EGFR tyrosine kinase activities
...Show More Authors

Scopus (23)
Scopus
Publication Date
Mon Jan 01 2024
Journal Name
Polski Merkuriusz Lekarski
Design, synthesis, insilco study and biological evaluation of new isatin-sulfonamide derivatives by using mono amide linker as possible as histone deacetylase inhibitors
...Show More Authors

Aim: To evaluate the cytotoxic activity of newly synthesized a series of novel HDAC inhibitors comprising sulfonamide as zinc binding group and Isatin derivatives as cap group joined by mono amide linker as required to act as HDAC inhibitors. Materials and Methods: The utilization of sulfonamide as zinc binding group joined by N-alkylation reaction with ethyl-bromo hexanoate as linker group that joined by amide reaction with Isatin derivatives as cap groups which known to possess antitumor activity in the designed of new histone deacetylase inhibitors and using the docking and MTT assay to evaluate the compounds. Results: Four compounds have been synthesized and characterized successfully by ART-FTIR, NMR and ESI-Ms. the compounds w

... Show More
View Publication
Scopus (2)
Scopus Crossref
Publication Date
Thu Jun 30 2022
Journal Name
Iraqi Journal Of Laser
PDF Treatment of intraoral pyogenic granuloma with diode laser 810-980 nmarch
...Show More Authors

Background: Pyogenic granuloma is a hyperplastic benign tumor. The most common intra-oral site is marginal gingiva. It is often occurred in the second decade of life, it has a strong tendency to recur after simple excision.

The aim of study: to evaluate the therapeutic advantages of diode laser (810-980 nm) in intraoral Pyogenic granuloma management.

Materials and method: A total of 28 patients (14 men and 14 females) were enrolled in this study and had their pyogenic granuloma surgically removed using a diode laser. All of the patients were given local anesthetic and went through the identical surgical procedure (cartridge containing 1 percent lidocaine with epinephrine 1:

... Show More
View Publication Preview PDF
Publication Date
Mon Jul 01 2013
Journal Name
Optics & Laser Technology
Evaluation of PMMA joining to stainless steel 304 using pulsed Nd:YAG laser
...Show More Authors

This paper reports an experimental study of welding of dissimilar materials between transparent Polymethylmethacrylate (PMMA) and stainless steel 304 sheets using a pulsed mode Nd:YAG laser. The process was carried out for two cases; laser transmission joining (LTJ) and conduction joining (CJ). The former is achieved when the joint is irradiated from the polymer side and the latter when the joint is irradiated from the opposite side (metal side). The light and process parameters represented by the peak power (Pp), pulse duration (τ), pulse repetition rate (PRR), scanning speed (ν) and pulse shape have a significant effect on the joint strength (Fb), joint bead width (b), joint quality and appearance. The optimum parameters were determined

... Show More
View Publication
Scopus (79)
Crossref (71)
Scopus Clarivate Crossref
Publication Date
Thu Feb 07 2019
Journal Name
Iraqi Journal Of Laser
Treatment of Skin Hyperpigmentation using Q-Switched (1064nm and 532nm) Nd:YAG Laser
...Show More Authors

Hyperpigmentation is the increase in the natural color of the skin. The purpose of this study is to evaluate the efficacy and safety of Q-Switched Nd:YAG (1064 & 532 nm) Laser in treatment of skin hyper pigmentation. This study was done in the research clinic of Institute of laser for postgraduate Studies/University of Baghdad from October 2008 to the end of January 2009. After clinical assessment of skin hyperpigmentation color, twenty six patients were divided according to their lesions. Eight Patients with freckles, seven patients with melasma, four patients with tattoo. Cases with tattoo, were subdivided into amateur tattoos two, professional tattoos one, and one traumatic tattoo. Four Patients with post inflammatory hyperpigment

... Show More
View Publication Preview PDF
Publication Date
Tue Oct 08 2002
Journal Name
Iraqi Journal Of Laser
Spatial Response Uniformity of Silicon–Based CdS and PbS Heterojunction Laser Detectors
...Show More Authors

This paper demonstrates the spatial response uniformity (SRU) of two types of heterojunctions (CdS, PbS /Si) laser detectors. The spatial response nonuniformity of these heterojunctions is not significant and it is negligible in comparison with p+- n silicon photodiode. Experimental results show that the uniformity of CdS /Si is better than that of PbS /Si heterojunction

View Publication Preview PDF
Publication Date
Thu Jun 08 2023
Journal Name
Iraqi Journal Of Laser
PDF Angular Laser Cleaning of Aluminum Al-4004 with Different Spot Sizes
...Show More Authors

Abstract: When it comes to applications in welding, cutting, and surface engineering, the utilization of high-power fiber-delivered beams from solid-state lasers offers several benefits. This paper addresses the issue of cleaning the surface of the samples with different spot sizes (50, 100 and 200) (industrial ytterbium fiber laser) to prepared it to be welded. Angular laser cleaning with incident angles (5, 10, 15, 20, 25, 30) ° with different powers (3, 5, 7, 10) W and hatch distance 0.001 was use for implemented.

View Publication Preview PDF
Publication Date
Mon Feb 04 2019
Journal Name
Iraqi Journal Of Physics
Gamma ray effect on the properties of R590 and C480 laser dyes
...Show More Authors

In the current research, we investigated the absorption spectrum for R590 and C480 dyes in ethanol solvent for different dye solution concentrations of 10-4, 10-5 and 10-6M. These dyes have been prepared and studied before and after gamma irradiation (first, second ionization) using cesium-137 source with absorbed doses of 18.36 Gy (time exposure of 10 days) and 73.44 Gy (with time exposure of 40 days). We noticed that the absorption intensity was decreased with decreasing concentration, before gamma irradiation while the absorption spectrum peak shifted towards the short wavelength (blue shift). It was also found that the intensity of absorption spectrum increased and shifted the absorption spectrum peak towards the long wavelength (red

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Jun 11 2002
Journal Name
Iraqi Journal Of Laser
Investigating the Effects of Carbon Dioxide Laser Fluence on Oral Soft Tissue
...Show More Authors

This study investigates the surgical and thermal effects on oral soft tissues produced by CO2 laser emitting at 10.6 micrometers with three different fluences 490.79, 1226.99 and 1840.4 J/cm2. These effects are specifically; incision depth, incision width and the tissue damage width and depth. The results showed that increasing the fluence and /or the number of beam passes increase the average depths of ablation. Moreover, increasing the fluence and the number of beam passes increase the adjacent tissue damage in width and depth. Surgeons using CO2 laser should avoid multiple pulses of the laser beam over the same area, to avoid unintentional tissue damage.

View Publication Preview PDF
Publication Date
Tue May 01 2012
Journal Name
Iraqi Journal Of Physics
Controlling the wavelength of a high power diode laser using thermoelectric cooler
...Show More Authors

The present work includes a design and characteristics study of a controlling the wavelength of high power diode laser by thermoelectric cooler [TEC] . The work includes the operation of the [TEC] to control the temperature of the diode laser between ( 0- +30) °C by changing the resistance of thermistor. We can control a limited temperature of a diode laser by changing the phase cooling between hot and cold faces of the diode, this process can be attempted by comparator type [LM –311] .The theoretical results give a model for controlling the temperature with, the suitable wavelength.

View Publication Preview PDF