The experimental proton resonance data for the reaction P+48Ti have been used to calculate and evaluate the level density by employed the Gaussian Orthogonal Ensemble, GOE version of RMT, Constant Temperature, CT and Back Shifted Fermi Gas, BSFG models at certain spin-parity and at different proton energies. The results of GOE model are found in agreement with other, while the level density calculated using the BSFG Model showed less values with spin dependence more than parity, due the limitation in the parameters (level density parameter, a, Energy shift parameter, E1and spin cut off parameter, σc). Also, in the CT Model the level density results depend mainly on two parameters (T and ground state back shift energy, E0), which are approximately constant in their behavior with the proton energy compared with GOE model. The RMT estimation used to calculate the corrections of the incompleteness proton resonance measurement data by using two methods; the conventional analysis method, which depends on the resonance widths and the updated, developed, tested and applied a new analysis method, which depends mainly on the resonance spacings. The spacing analysis method is found much less sensitive to non-statistical phenomena than is the width analysis method. Where the analysis of a given data set via these two independent analysis methods indicated the increasing in the reliability of the determination of the missing fraction of levels, the observed fraction f between 0.87+0.13−0.11 – 0.68+0.12−0.12 for different spin-parity of this reaction and then the distinguishability in the level density calculations can be achieved. The modified Porter Thomas distribution along with the maximum likelihood function have been used to get the missing levels corrections for 5 proton resonance sequences in the present reaction. To estimate the present long-range correlations for pure sequence of levels the mean square of the deviation of the cumulative number of levels from a fitted straight line represented by the Dyson and Mehta Δ3 statistic has been employed for spin parity 12+, and calculated the <Δ3> against the cumulative number of proton levels.
Diabetes is a disease caused by high sugar levels. Currently, diabetes is one of the most common diseases in the number of people with diabetes worldwide. The increase in diabetes is caused by the delay in establishing the diagnosis of the disease. Therefore, an initial action is needed as a solution that requires the most appropriate and accurate data mining to manage diabetes mellitus. The algorithms used are artificial neural network algorithms, namely Restricted Boltzmann Machine and Backpropagation. This research aims to compare the two algorithms to find which algorithm can produce high accuracy, and determine which algorithm is more accurate in detecting diabetes mellitus. Several stages were involved in this research, including d
... Show MoreA widespread variety of toxicants modify miRNAs profiles in target tissues. Five rat treatment groups were selected for this study, each consisting of five animals and an additional one left untreated used as a control. Administration of the carcinogen 4-Nitroquinoline (4-NQO) lasted for 5 months with four weeks intervals separating the successive groups. When the carcinogen intake period ended, the animals were euthanized and renal tissue was collected for both histopathological and molecular investigations. The results showed no significant difference (p=0.65) between the animal groups that showed kidney tissue toxicity and those that did not. Conversely, a statistically significant difference emerged if the m
... Show MoreThis study aimed to determine the effects of age, gender, and allergen type on serum immunoglobulin E (IgE) levels in asthma (AS) and allergic rhinitis (AR) patients. Sixty AS patients, 52 AR patients, and 61 controls were enrolled in the study. Sera of participants were assessed for total IgE level and specific IgE antibody against four allergen types (animal dander, grasses, mites, and molds). The results revealed that median level of total IgE was significantly increased in AS (218.9 IU/mL; p-value < 0.001) and AR (244.3 IU/mL; p-value < 0.001) patients compared to controls (167.1 IU/mL), while, there was no significant difference between AS and AR patients (p-value = 0.270). Logistic regression
... Show MoreMany pathophysiological processes can affect the pharmacokinetic properties of drugs in people with diabetes. The present study was deigned to evaluate the influence of diabetes mellitus (DM) on the pharmacokinetic parameters of metronidazole administered as single oral dose. Twelve healthy volunteers and twelve diabetic patients were enrolled in the present study. On day 1, a single oral dose of metronidazole 500 mg was administered orally to all participants at 9:00 am after a 10-hour fasting. Over the following 48 hours, blood samples were taken at frequent intervals and serum metronidazole concentrations were measured by a high-performance liquid chromatography method for assessment of pharmacokinetics of metronidazole. The data
... Show MoreMany pathophysiological processes can affect the pharmacokinetic properties of drugs in people with diabetes. The present study was deigned to evaluate the influence of diabetes mellitus (DM) on the pharmacokinetic parameters of metronidazole administered as single oral dose. Twelve healthy volunteers and twelve diabetic patients were enrolled in the present study. On day 1, a single oral dose of metronidazole 500 mg was administered orally to all participants at 9:00 am after a 10-hour fasting. Over the following 48 hours, blood samples were taken at frequent intervals and serum metronidazole concentrations were measured by a high-performance liquid chromatography method for assessment of pharmacokinetics of metronid
... Show MoreIn this research the active volume for a number of solid-state detectors of the type of high-purity germanium (HPGe) crystal was evaluated with different radii and depths using scanning method for diagonal (front) and lateral (side). It has been used for this purpose Monte-Carlo efficiency program after its development by adding a subroutine-program for its (subroutine scanning).Also a program has been written to calculate the stopping power and range for incident charged particle on the detector, in order to determine the exact sufficient energy to stop it inside the detector material. The calculations of our results of efficiency were compared with the results of published efficiency and the comparison is very good in terms of improvin
... Show More