Preferred Language
Articles
/
ijp-256
Experimental investigation of dusty plasma characteristics in AC discharge system
...Show More Authors

In the present work, the effect of size of zinc dust particles on
AC argon discharge characteristics are investigated
experimentally. The plasma characteristics are determined by
using optical emission spectroscopy (OES) techniques. The
results illustrated that the electron temperature (Te) in the present
and absent of Zinc dust particle is reduced with increasing of
pressure. The electron temperature decreases with increasing of
Zinc dust size. Excitation temperature Tex is reduces with
increasing of Ar pressure in present and absent of zinc dust
particles. The present of Zinc dust reduce the Tex of Ar in both
Zinc dust size. The electron density increasing in the present and
absent of both zinc dust size. Furthermore, the introduced of zinc
dust in AC discharge increasing of ne.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Oct 01 2010
Journal Name
Iraqi Journal Of Physics
Analysis of Initiation and Growth of Plasma Channels Within Non-Mixed Dielectric Liquids
...Show More Authors

Pre-breakdown phenomenon was investigated within the two, non-mixed dielectric liquids; transformation oil and cresol. Finite element technique was used to follow the initiation and growth of plasma channels (streamer discharge) within pin-plane configuration. That was done for different spacing between the pin-electrode and the liquid-liquid interface. Streamer growth model assumed that, the streamer initiation occurs at the region of the highest value of electric field. Our study shows that the streamer initiates at the tip of the pin and growths toward the other electrode. The study shows, too, that the streamer path controlled by the difference of permittivity of the two liquids and spacing distance of the liquid-liquid interface fro

... Show More
View Publication Preview PDF
Publication Date
Thu Mar 31 2022
Journal Name
Journal Of The College Of Education For Women
Characteristics of Rainfall in Dry and Wet Seasons in Iraq
...Show More Authors

      This research aims at making a comparative survey between the dry season in (2017-2018) and the wet season (2018-2019) in Iraq concerning the variation of rainfall and pressure systems responsible for such a difference. In this paper, seven climatological stations have been selected: Mosul, Kirkuk, Khanaqin, Baghdad, Rutba, Diwaniyah and Basra. Results have shown that the first category of rainfall of the two seasons has recorded a higher number of rainy days in comparison with the second and third categories with a total of 274 day in a dry season and 403 day of a wet season. Further, the total amount of the annual continuous rain is higher than the total of thunderstorms in a dry season as well as in the

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Aug 29 2016
Journal Name
Kufa Journal For Nursing Sciences
Atherogenic Index of Plasma Levels in Patients with Diabetic and Neurodiabetic
...Show More Authors

Objectives: To determined the levels of lipid profile (TC, TG, HDL-c, LDL-C, VLDL) in diabetic and diabetic neuropathy patients and compare the results with control group. Also, to compare Atherogenic Index of Plasma (AIP) levels in these groups that may be predict prone of patients to cardiovascular disease. Methodology: Ninety subjects were enrolled in this study with aged ranged (40-65) years and BMI with (30-35) Kg/m2 that divided into three groups as follows: group one (G1) consists of 30 healthy individuals as a control group, group two (G2) consists of 30 patients with diabetes and group three (G3) consists of 30 patients with diabetes and neuropathy as complication. Electrochemical Skin Conductance (Feet Mean), Electrochemic

... Show More
View Publication
Crossref
Publication Date
Sun Aug 06 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Study of The Dynamical Behavior For Deuterons in Dense Plasma Focus
...Show More Authors

    The motion of fast deuterons in most dense plasma focus devices  ( DPF ) , may be characterized that it has a complex nature in its paths and this phenomena by describing a through gyrating motion with arbitrary changes in magnitude and direction .  In this research , we focused on the  understanding the theoretical concepts which  depend deeply on the experimental results to explain the deuteron motions in the pinch region , and then to use the fundamental physical formulas that are deeply related to the explanation of this motion to prepare a suitable model for calculating the vertical and radial components for deuteron velocity by improving the  Rung – Kutta  Method

View Publication Preview PDF
Publication Date
Wed Mar 01 2023
Journal Name
Baghdad Science Journal
Traveling Wave Solutions of Fractional Differential Equations Arising in Warm Plasma
...Show More Authors

This paper aims to study the fractional differential systems arising in warm plasma, which exhibits traveling wave-type solutions. Time-fractional Korteweg-De Vries (KdV) and time-fractional Kawahara equations are used to analyze cold collision-free plasma, which exhibits magnet-acoustic waves and shock wave formation respectively. The decomposition method is used to solve the proposed equations. Also, the convergence and uniqueness of the obtained solution are discussed. To illuminate the effectiveness of the presented method, the solutions of these equations are obtained and compared with the exact solution. Furthermore, solutions are obtained for different values of time-fractional order and represented graphically.

View Publication Preview PDF
Scopus (3)
Scopus Clarivate Crossref
Publication Date
Mon Oct 01 2012
Journal Name
Iraqi Journal Of Physics
Double probe for measuring the plasma parameters
...Show More Authors

In this work the diode planer magnetron sputtering device was
designed and fabricated. This device consists of two aluminum discs
(8cm) diameter and (5mm) thick. The distance between the two
electrodes is 2cm, 3cm, 4cm and 5cm.
Design and construction a double probe of tungsten wire with
(0.1mm) diameter and (1.2mm) length has been done to investigate
electron temperature, electron and ion density under different
distances between cathode and anode. The probes were situated in
the center of plasma between anode and cathode.
The results of this work show that, when the distance between
cathode and anode increased, the electron temperature decreased.
Also, the electron density increases with the increasing

... Show More
View Publication Preview PDF
Publication Date
Mon Oct 09 2023
Journal Name
Journal Of Legal Sciences
Experimental Article
...Show More Authors

Due to its safety, low cost, real-time nature, and widespread availability, ultrasound has been employed as a diagnostic technique for numerous intraocular disorders. Unfortunately, speckle artifact that depends on the tissue is seen in ultrasound imaging. In this study, we present a technique for lowering speckle noise and enhancing ultrasound images to enhance human diagnostic performance. This technique combines the undecimated wavelet transform (UDWT) with a wavelet coefficient mapping function, which was utilized to improve the contrast of the denoised images acquired from the first component after the noise was removed using the UDWT. This technique can be used to enhance the visual quality of medical photographs as well as to enha

... Show More
View Publication Preview PDF
Publication Date
Sun Feb 03 2019
Journal Name
Iraqi Journal Of Physics
Influence of non-thermal argon plasma needle on blood coagulation
...Show More Authors

Non-thermal argon plasma needle at atmospheric pressure was
constructed. The experimental setup was based on a simple and low
cost electric component that generates a sufficiently high electric
field at the electrodes to ionize the argon gas which flow at
atmospheric pressure. A high AC power supply was used with 1.1
kV and 19.57 kHz. Non-thermal Argon plasma used on blood
samples to show the ability of non-thermal plasma to promote blood
coagulation. Three tests have been done to show the ability of plasma
to coagulate both normal and anti-coagulant blood. Each blood
sample has been treated for varying time from 20sec. to 180sec. at
different distances. The results of the current study showed that the
co

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Sep 01 2022
Journal Name
Iraqi Journal Of Physics
The Effect of Power on Inductively Coupled Plasma Parameters
...Show More Authors

In this work, we studied the effect of power variation ​​on inductively coupled plasma parameters using numerical simulation. Different values ​​were used for input power (750 W-1500 W), gas temperature 300K, gas pressure (0.02torr),         5 tourns of the copper coil and the plasma was produced at radio frequency (RF) 13.56 MHZ on the coil above the quartz chamber. For the previous purpose, a computer simulation in two dimensions axisymmetric, based on finite element method, was implemented for argon plasma. Based on the results we were able to obtain plasma with a higher density, which was represented by obtaining the plasma parameters (electron density, electric potential, total power, number density of argon ions, el

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sun Mar 04 2018
Journal Name
Baghdad Science Journal
Effects of Gas Flow on Spectral Properties of Plasma Jet Induced by Microwave
...Show More Authors

In this paper, a construction microwave induced plasma jet(MIPJ) system was used to produce a non-thermal plasma jet at atmospheric pressure, at standard frequency of 2.45 GHz and microwave power of 800 W. The working gas Argon (Ar) was supplied to flow through the torch with adjustable flow rate using flow meter regulator. The influence of the MIPJ parameters such as applied voltage and argon gas flow rate on macroscopic microwave plasma parameters were studied. The macroscopic parameters results show increasing of microwave plasma jet length with increasing of applied voltage, argon gas flow rate where the plasma jet length exceed 12 cm as maximum value. While the increasing of argon gas flow rate will cause increasing into the ar

... Show More
View Publication Preview PDF
Scopus (16)
Crossref (4)
Scopus Clarivate Crossref